| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 27, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION OF AN INACTIVE 14-STORY BUILDING, NO WATCHPERSON WAS PRESENT. INSPECTOR KNOCKED AT EACH SITE GATE AND YELLED TO CONTACT SITE PERSONNEL, BUT RECEIVED NO RESPONSE. REQUIRED WATCHPERSON WAS N #39559807L | Dec 4, 2026 | $2,500 |
| Sep 22, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED TWO PROPERTIES ACTIVELY WORKING. THERE IS A CCD1 APPROVED TO HAVE 1 DESIGNATED SITE SAFETY MANAGER FOR BOTH PROPERTIES. INSTEAD THERE IS 1 SITE SAFETY COORDINATOR DESIGNATED TO B #39559478J | Dec 4, 2026 PENDING | $2,500 |
| Aug 27, 2026 | Construction CLASS - 2 WORK DOES NOT CONFORM TO PLANS. AT TIME OF INSPECTION, APPROVED DOB ENERGY AND ARCHITECTURAL DRAWINGS FOR WALL TYPE WA1 TO HAVE A R-VALUE OF 8.5 AS CONTINUOUS INSULATION. UPON INSPECTION, CONTRACTOR INSTALLED 2 #39202157R | Nov 6, 2026 PENDING | $1,250 |
| Jan 7, 2026 | Construction CLASS - 1 AT THE TIME OF INSPECTION, I OBSERVED A GRINDER AT EXCAVATION SITE MISSING THE BLADE GUARD AND AUXILIARY HANDLE, NOT IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS, CREATING AN UNSAFE CONDITION LEADING TO INJUR #39548898M | May 10, 2027 | $2,500 |
| Jan 7, 2026 | Construction CLASS - 1 UPON REVIEW OF THE APPROVED SITE SAFETY EXCAVATION PLAN DURING INSPECTION, I OBSERVED THAT REQUIRED EGRESS WAS NOT PROVIDED AT EXP #2, AND THE EXITING CONDITION ON SITE DID NOT REFLECT THE SITE SAFETY PLAN AS P #39548899Y | May 10, 2027 | $2,500 |
| Jan 7, 2026 | Construction CLASS - 1 AT THE TIME OF INSPECTION OF A PROPOSED 13-STORY NEW BUILDING, THE SITE WAS ACTIVE AND IN THE EXCAVATION PHASE. I OBSERVED THAT NO GUARDRAIL SYSTEM WAS IN PLACE AT EXP #2 ALONG THE EDGE OF THE EXCAVATED AREA, P #39548896Z | May 10, 2027 | $5,000 |
| Jan 7, 2026 | Site Safety CLASS - 1 AT TIME OF INSPECTION OF A PROPOSED 13 STORY NEW BUILDING AT EXCAVATION PHASE, OBSERVED NO COMPLETE APPROVED SET OF SUPPORT-OF-EXCAVATION DRAWINGS ON SITE AS REQUIRED. CONTRARY TO BC 3301.7. FAILURE TO MAINTAIN #39548861Z | May 10, 2027 | $2,500 |
| Jan 7, 2026 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A PROPOSED 13-STORY NEW BUILDING, I OBSERVED YODOCK BARRIERS STORED AT THE EDGE OF THE EXCAVATED AREA AT EXP #2. THIS UNSAFE STORAGE OF CONSTRUCTION MATERIALS POSED A RISK OF STR #39548897K | May 10, 2027 | $2,500 |
None open.
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 27, 2026 | ECB | Unknown: AT TIME OF INSPECTION OF AN INACTIVE 14-STORY BUILDING, NO WATCHPERSON WAS PRESENT. INSPECTOR KNOCKED AT EACH SITE GATE AND YELLED TO CONTACT SITE PERSONNEL, BUT RECEIVED NO RESPONSE. REQUIRED WATCHPERSON WAS N | Closed |
| Sep 22, 2026 | ECB | Construction: AT TIME OF INSPECTION OBSERVED TWO PROPERTIES ACTIVELY WORKING. THERE IS A CCD1 APPROVED TO HAVE 1 DESIGNATED SITE SAFETY MANAGER FOR BOTH PROPERTIES. INSTEAD THERE IS 1 SITE SAFETY COORDINATOR DESIGNATED TO B | Open |
| Aug 27, 2026 | ECB | Construction: WORK DOES NOT CONFORM TO PLANS. AT TIME OF INSPECTION, APPROVED DOB ENERGY AND ARCHITECTURAL DRAWINGS FOR WALL TYPE WA1 TO HAVE A R-VALUE OF 8.5 AS CONTINUOUS INSULATION. UPON INSPECTION, CONTRACTOR INSTALLED 2 | Open |
| Aug 1, 2026 | ECB | Unknown: BC3303.3 ON 14-STORY NB WAS NO CONSTRUCTION ACTIVITIES. I KNOCKED AT SEVERAL LOCATIONS ON PERIMETER FENCE AND ENTRY DOORS ATTEMPT TO LOCATE A WATCHPERSON OR SECURITY ON SITE NONE WAS PRESENT AS REQUIRED BY COD | Closed |