Bronx · Block 4286 · Lot 40 · 10462

Maran Place

class V1 · owner of record: 2111 White Plains Llc

0open violations
$82,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
—no dated deadlines found

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

We couldn't find building attributes for this lot, so no deadlines are listed.

Open violations

ECB / OATH (14) · $82,500 owed
IssuedViolationHearingBalance
Jun 30, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION OF A 9-STORY PROPOSED NEW BUILDING, ACTIVE SITE I OBSERVED THROUGHOUT JOBSITE INTERIOR, INSIDE BUILDING POOL OF STANDING WATER ON ALL FLOORS, CREATING A HAZARDOUS CONDITION FOR WORKERS
#39556010K
Mar 19, 2027
$2,500
Jun 24, 2026Cranes and Derricks CLASS - 1
RESPONDENT(LIFT DIRECTOR) PERMITTED MOBILE CRANE CN#924/25 CD#5813 TO HOIST MATERIALS ON JOB SITE IN AN OVER 250 CONFIGURATION THOUGH NO D.O.B INSPECTOR WAS ON SITE TO APPROVE SIGN OFF., DISCONTINUE USE; HAVE D
#39193625R
Mar 19, 2027
$10,000
Jun 24, 2026Cranes and Derricks CLASS - 1
RESPONDENT ERECTED AND OPERATED MOBILE CRANE CN#924/25 CD#5813 AND HOISTED MATERIALS ON JOB SITE IN AN OVER 250 COFIGURATION THOUGH NO D.O.B INSPECTOR WAS ON SITE TO APPROVE SIGN OFF, DISCONTINUE USE; HAVE D.O.
#39193612H
Mar 19, 2027
$10,000
Jun 24, 2026Cranes and Derricks CLASS - 1
RESPONDENT PERMITTED THE USE OF MOBILE CRANE CN#924/25 CD#5813 TO HOIST MATERIALS ON JOB SITE IN AN OVER 250 CONFIGURATION THOUGH NO D.O.B INSPECTOR WAS ON SITE TO APPROVE SIGN OFF., DISCONTINUE USE; HAVE D.O.B
#39193635K
Mar 19, 2027
$10,000
Jun 24, 2026Cranes and Derricks CLASS - 1
RESPONDENT ERECTED AND USED MOBILE CRANE CN#924/25 CD#5813 TO HOIST MATERIALS ON JOB SITE IN AN OVER 250 CONFIGURATION THOUGH NO D.O.B INSPECTOR WAS ON SITE TO APPROVE SIGN OFF., DISCONTINUE USE; HAVE D.O.B REP
#39193628M
Mar 19, 2027
$10,000
Apr 29, 2026Construction CLASS - 1
AT TIME OF INSPECTION ACTIVE SITE AT 4-STORY PROPOSED 9-STORY BUILDING. GUARDRAILS AT ROOF LEVEL NOT IN COMPLIANCE WITH CODE REQUIREMENTS. INADEQUATE PROTECTION OBSERVED AT OPEN EDGES AND WORKING DECK AREAS, CR
#39553610K
Jan 15, 2027
$5,000
Apr 29, 2026Unknown CLASS - 2
AT TIME OF INSPECTION ACTIVE SITE AT 4-STORY PROPOSED 9-STORY BUILDING. STORAGE ZONE OBSERVED WITHOUT PROPER ENCLOSURE/REQUIRED 4-FOOT BARRIER PROTECTION. CONDITION MAY ALLOW UNAUTHORIZED ACCESS AND CREATE UNSA
#39553612Y
Jan 15, 2027
$2,500
Apr 29, 2026Construction CLASS - 1
AT TIME OF INSPECTION ACTIVE SITE AT 4-STORY PROPOSED 9-STORY BUILDING WITH ACTIVE SIDEWALK SHED PERMIT X01120969-I1-SH. SHED NOT IN ACCORDANCE WITH APPROVED PLANS; INSTALLED AT 10 TO 12 FT WHILE DESIGN REQUIRE
#39553617N
Jan 22, 2027
$2,500
Apr 29, 2026Site Safety CLASS - 1
AT TIME OF INSPECTION ACTIVE SITE AT 4-STORY PROPOSED 9-STORY BUILDING WITH PRECAST SLAB INSTALLATION OBSERVED. NO ENGINEERED SHOP DRAWINGS FOR RESHORING PROVIDED ON SITE. REQUIRED DOCUMENTATION NOT MAINTAINED
#39553609N
Jan 15, 2027
$2,500
Mar 26, 2026Unknown CLASS - 1
RESPONDENT USED MOBILE CRANE CN#925/25 CD#5027 TO HOIST MATERIALS ON JOBSITE KNOWING THAT THERE WAS NO LIFT DIRECTOR ON SITE., LIFT DIRECTORTO REPORT TO SITE
#39182001P
Nov 13, 2026
$10,000
Mar 26, 2026Unknown CLASS - 2
OBSERVED ACTIVE JOBSITE IN SUPERSTRUCTURE PHASE WITH MOBILE CRANE. ADJACENT PROPERTY AT EXPOSURE 3 OF JOBSITE HAS NOT BEEN PROVIDED WINDOW PROTECTION AGAINST ONGOING OPERATIONS. STOP ALL EXTERIOR WORK EXPOSURE
#39552246Z
Dec 3, 2026
$2,500
Mar 26, 2026Unknown CLASS - 1
RESPONDENT PERMITTED MOBILE CRANE CN#925/25 CD#5027 TO HOIST MATERIALS ON JOBSITE KNOWING THAT THERE WAS NO LIFT DIRECTOR ON SITE., LIFT DIRECTOR TO REPORT TO SITE
#39181989J
Nov 13, 2026
$10,000
Mar 26, 2026Construction CLASS - 1
RESPOND WAS PERFORMING DUTIES AS LIFT DIRECTOR USING MOBILE CRANE CN#925/25 CD#5027, KNOWING HE DOES NOT POSSESS A LIFT DIRECTOR"S LICENSES.; COMPLY, COMPLY WITH RULE
#39182013M
Nov 13, 2026
$2,500
Aug 28, 2025Site Safety CLASS - 1
DURING MY INSPECTION OF AN ACTIVE PROPOSED 8-STORY NB AT THE SOE PHASE. I REQUESTED TO REVIEW THE APPROVED SOE PLANS, BUT NO PLANS WERE PROVIDED. STOP ALL SOE OPERATIONS, MAINTAIN THE REQUIRED APPROVED SOE PLA
#39544232H
Oct 16, 2026
$2,500
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Aug 12, 2026DOB SafetyAEUHAZ: Closed
Aug 12, 2026DOB SafetyAEUHAZ: Closed
Aug 12, 2026DOB SafetyAEUHAZ: Closed
Aug 12, 2026DOB SafetyAEUHAZ: Closed
Jun 30, 2026ECBConstruction: AT THE TIME OF INSPECTION OF A 9-STORY PROPOSED NEW BUILDING, ACTIVE SITE I OBSERVED THROUGHOUT JOBSITE INTERIOR, INSIDE BUILDING POOL OF STANDING WATER ON ALL FLOORS, CREATING A HAZARDOUS CONDITION FOR WORKERSClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 22, 2026, 2:57 PM ET. BBL 2042860040.