14 floors · 326 apartments · 241,465 sq ft · built 2022 · class D1 · owner of record: Starhill Phase I Housing Development Fun D Corporat
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 65 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 81 days | Annual |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | Feb 21, 2027 in 117 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 241,465 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1161 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2865). Agency page | Dec 31, 2035 in 3352 days | Next due 2035 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-14 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 21, 2026 | Elevators CLASS - 2 CLASS 2: COUNTERWEIGHTS PRODUCE EXCESSIVE NOISE IN MOTION; METAL SHAVINGS OBSERVED AT BOTTOM OF COUNTERWEIGHT, INDICATING IMPROPER ALIGNMENT AND/OR INADEQUATE LUBRICATION. RAILS APPEARED DRY AS PER ASME A17.1 8 #39197013Y | Oct 2, 2026 ADMIT/IN-VIO | $0 |
| Jul 21, 2026 | Elevators CLASS - 2 CLASS 2 RTS: UPON INSPECTION, DEVICE FOUND OUT OF SERVICE, CONFIRMING CONTINUED OPERATIONAL INSTABILITY CONTRARY TO ASME A17.1 8.6.1.2 REQUIREMENTS FOR MAINTENANCE AND RELIABLE PERFORMANCE. DOB RECORDS INDICATE #39197014X | Oct 2, 2026 ADMIT/IN-VIO | $0 |
| May 18, 2026 | Elevators CLASS - 2 RESPONDING TO A 311 COMPLAINT. FOUND THE DEVICE NOT WORKNG. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987 REMEDY REPAIR AND EMAIL EIR FOR RE- INSPECTION #39189067J | Aug 7, 2026 STIPULATION/IN-VIO | $0 |
| May 18, 2026 | Elevators CLASS - 2 RESPONDING TO A311 COMPLAINT, UPON INSPECTION FIND THE DEVICE NOT WORKING. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987 REMEDY RESTORE TO SERVICE AND EMAIL EIR FOR RE-INSPECTION #39189059J | Aug 7, 2026 STIPULATION/IN-VIO | $0 |
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 23, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT COMPACTOR CLOSET DOOR AT COMPACTOR CLOSET, 14th STORY | Nov 6, 2026 |
| Oct 23, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT THE HOPPER CHUTE DOOR AT COMPACTOR CLOSET, 14th STORY | Nov 6, 2026 |
| Oct 23, 2026 | B | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY CAPS AND COVERS FOR ELECTRICAL OUTLETS AT NORTH AND EAST WALLS AT PUBLIC HALL, 1st STORY | Nov 27, 2026 |
| Oct 23, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT STAIRS 'A' DOOR AT EAST WALL AT PUBLIC HALL, 1st STORY | Nov 6, 2026 |
| Oct 22, 2026 | C | § 27-2029 ADM CODE DEVICE PRESENT ON CENTRAL HEATING SYSTEM WHICH IS CAPABLE OF CAUSING AN OTHERWISE OPERABLE SYSTEM TO BECOME INOPERABLE DUE TO IMPROPERLY SET DEVICE AT LOWER HEATING AT BOILER ROOM | Oct 22, 2026 |
| Oct 22, 2026 | C | Apt 1402 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1402, 14th STORY, 3rd APARTMENT FROM NORTH AT EAST | Oct 22, 2026 |
| Oct 15, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT COMPACTOR CLOSET, 5th STORY | Oct 29, 2026 |
| Oct 15, 2026 | B | Apt 312 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 312, 3rd STORY, 9th APARTMENT FROM SOUTH AT WEST | Nov 19, 2026 |
| Oct 6, 2026 | B | Apt 804 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 804, 8th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 10, 2026 |
| Oct 6, 2026 | B | Apt 804 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 804, 8th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 10, 2026 |
| Oct 5, 2026 | C | Apt 804 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 804, 8th STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 3, 2026 |
| Oct 5, 2026 | C | § 27-2029 ADM CODE DEVICE PRESENT ON CENTRAL HEATING SYSTEM WHICH IS CAPABLE OF CAUSING AN OTHERWISE OPERABLE SYSTEM TO BECOME INOPERABLE ... AT BOILER ROOM | Oct 3, 2026 |
| Sep 28, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Oct 4, 2026 |
| Sep 28, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 1st STORY | Jan 1, 2027 |
| Sep 28, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 1st STORY | Nov 2, 2026 |
| Aug 14, 2026 | C | Apt 526 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 526, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 12, 2026 |
| Aug 14, 2026 | C | Apt 409 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 409, 4th STORY, 6th APARTMENT FROM SOUTH AT WEST | Aug 12, 2026 |
| Jul 13, 2026 | C | Apt 526 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 526, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jul 11, 2026 |
| Jul 9, 2026 | C | Apt 1108 · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT BATHROOM AND KITCHEN IN THE ENTIRE APARTMENT LOCATED AT APT 1108, 11th STORY, 9th APARTMENT FROM SOUTH AT WEST | Jul 15, 2026 |
| Jul 9, 2026 | C | Apt 1108 · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT BATHROOM AND KITCHEN IN THE ENTIRE APARTMENT LOCATED AT APT 1108, 11th STORY, 9th APARTMENT FROM SOUTH AT WEST | Jul 15, 2026 |
| Jul 7, 2026 | B | Apt 1216 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CELING IN THE 3rd ROOM FROM EAST LOCATED AT APT 1216, 12th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Aug 11, 2026 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 23, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT COMPACTOR CLOSET DOOR AT COMPACTOR CLOSET, 14th STORY | Open |
| Oct 23, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT THE HOPPER CHUTE DOOR AT COMPACTOR CLOSET, 14th STORY | Open |
| Oct 23, 2026 | HPD B | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY CAPS AND COVERS FOR ELECTRICAL OUTLETS AT NORTH AND EAST WALLS AT PUBLIC HALL, 1st STORY | Open |
| Oct 23, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT STAIRS 'A' DOOR AT EAST WALL AT PUBLIC HALL, 1st STORY | Open |
| Oct 22, 2026 | HPD C | § 27-2029 ADM CODE DEVICE PRESENT ON CENTRAL HEATING SYSTEM WHICH IS CAPABLE OF CAUSING AN OTHERWISE OPERABLE SYSTEM TO BECOME INOPERABLE DUE TO IMPROPERLY SET DEVICE AT LOWER HEATING AT BOILER ROOM | Open |
| Oct 22, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1402, 14th STORY, 3rd APARTMENT FROM NORTH AT EAST | Open |
| Oct 15, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT COMPACTOR CLOSET, 5th STORY | Open |
| Oct 15, 2026 | HPD B | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 312, 3rd STORY, 9th APARTMENT FROM SOUTH AT WEST | Open |
| Oct 6, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 804, 8th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Oct 6, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 804, 8th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Oct 5, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 804, 8th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Oct 5, 2026 | HPD C | § 27-2029 ADM CODE DEVICE PRESENT ON CENTRAL HEATING SYSTEM WHICH IS CAPABLE OF CAUSING AN OTHERWISE OPERABLE SYSTEM TO BECOME INOPERABLE ... AT BOILER ROOM | Open |
| Sep 28, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1402, 14th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Closed |
| Sep 28, 2026 | HPD C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Open |
| Sep 28, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 1st STORY | Open |
| Sep 28, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 1st STORY | Open |
| Aug 14, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 526, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Aug 14, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 409, 4th STORY, 6th APARTMENT FROM SOUTH AT WEST | Open |
| Aug 7, 2026 | HPD C | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT ALL ELECTRICAL OUTLETS AND LIGHT FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 605, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Closed |
| Jul 22, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1402, 14th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''01-06'', AT SOUTH | Closed |
| Jul 22, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 409, 4th STORY, 6th APARTMENT FROM SOUTH AT WEST , SECTION ''01-10'', AT SOUTH | Closed |
| Jul 22, 2026 | HPD B | § 27-2010, 2011, 2012 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE SEWAGE AT PUBLIC HALL, 4th STORY | Closed |
| Jul 22, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 512, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''11-29'', AT NORTH | Closed |
| Jul 21, 2026 | ECB | Elevators: CLASS 2: COUNTERWEIGHTS PRODUCE EXCESSIVE NOISE IN MOTION; METAL SHAVINGS OBSERVED AT BOTTOM OF COUNTERWEIGHT, INDICATING IMPROPER ALIGNMENT AND/OR INADEQUATE LUBRICATION. RAILS APPEARED DRY AS PER ASME A17.1 8 | Open |
| Jul 21, 2026 | ECB | Elevators: CLASS 2 RTS: UPON INSPECTION, DEVICE FOUND OUT OF SERVICE, CONFIRMING CONTINUED OPERATIONAL INSTABILITY CONTRARY TO ASME A17.1 8.6.1.2 REQUIREMENTS FOR MAINTENANCE AND RELIABLE PERFORMANCE. DOB RECORDS INDICATE | Open |