class V1 · owner of record: Bedford 1456 Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
We couldn't find building attributes for this lot, so no deadlines are listed.
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 12, 2026 | Unknown CLASS - 1 BC 3307.4.7 AT THE TIME OF MY INSPECTION OF A 5 STORY NEW BUILDING, I OBSERVED AT EXPOSURE #1 ADJACENT TO SIDEWALK SHED MATERIALS STORED ON STREET, 2 PORTABLE TOILET, THERE WERE NO SOLID PLYWOOD BARRIER FROM GR #39560459M | Dec 16, 2026 PENDING | $5,000 |
| Aug 27, 2026 | Unknown CLASS - 2 BC3314.1 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED ON TOP OF SIDEWALK SHED EXP#1. LOOSE PLANKS NOT TIED DOWN / SECURED. NETTING NOT FULLY ENCLOSING SCAFFOLD NOT FASTENED TO FACADE. CREATED H #39558476L | Nov 4, 2026 | $2,500 |
| Jul 20, 2026 | Construction CLASS - 2 OBSERVED JERSEY BARRIERS AT EXP#1 NOT AS PER MANUFACTURES SPECIFICATION. JERSEY BARRIERS NOT INTERLOCKED FILL WITH WATER/SAND WHICH POSES A POTENTIAL HAZARD BY ALLOWING UNINTENDED MOVEMENT OF THE BARRIERS INCR #39556865X | Oct 7, 2026 IN VIOLATION | $1,250 |
| Mar 27, 2026 | Construction CLASS - 1 BC 3309.4 AT THE TIME OF INSPECTION OBSERVED AT EXPOSURES 2 & 4, ADJACENT BUILDINGS ON RUBBLE FOUNDATIONS SHOW EXPOSED WITH STONE LOSS PATCHED IMPROPERLY. EXPOSURE 2 NOT PROPERLY PARGE OR WEATHERPROOF. MULTIPLE #39552311X | Jan 14, 2027 | $5,000 |
| Feb 19, 2026 | Site Safety CLASS - 1 AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE FAILED TO PROVIDE UPON REQUEST CONSTRUCTION DOCUMENTS:3309.16-NO VIBRATION MONITORING REPORT FOR MECHANICAL DEVICE INSERTED IN THE BUILDINGS STRUCTURE @ EXP. 2& #39550580P | Jan 14, 2027 | $2,500 |
| Feb 19, 2026 | Unknown CLASS - 1 AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE IMPROPERLY STORED OXYGEN & ACETYLENE TANKS & SOME LAYING DOWN CREATED COMBUSTIBLE ENVIRONMENT 3313.1 THIS MISUSE CAN EFFECT ALL WORKERS, PUBLIC & PROPERTY. STOP #39550582Z | Jan 14, 2027 | $5,000 |
| Feb 19, 2026 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE FAILED TO FULLY ERECT CONSTRUCTION FENCE @ EXP. 2 & 4 EXPOSING BOTH ADJOINING PROPERTIES WHILE STARTING COMMERCE OF MECHANICAL PILEDRIVER EQUIPMENT. BC 3307.7 M #39550586X | Jan 14, 2027 | $1,000 |
None open.
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 12, 2026 | ECB | Unknown: BC 3307.4.7 AT THE TIME OF MY INSPECTION OF A 5 STORY NEW BUILDING, I OBSERVED AT EXPOSURE #1 ADJACENT TO SIDEWALK SHED MATERIALS STORED ON STREET, 2 PORTABLE TOILET, THERE WERE NO SOLID PLYWOOD BARRIER FROM GR | Open |
| Aug 27, 2026 | ECB | Unknown: BC3314.1 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED ON TOP OF SIDEWALK SHED EXP#1. LOOSE PLANKS NOT TIED DOWN / SECURED. NETTING NOT FULLY ENCLOSING SCAFFOLD NOT FASTENED TO FACADE. CREATED H | Closed |
| Jul 20, 2026 | ECB | Construction: OBSERVED JERSEY BARRIERS AT EXP#1 NOT AS PER MANUFACTURES SPECIFICATION. JERSEY BARRIERS NOT INTERLOCKED FILL WITH WATER/SAND WHICH POSES A POTENTIAL HAZARD BY ALLOWING UNINTENDED MOVEMENT OF THE BARRIERS INCR | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 12:09 PM ET. BBL 3012380039.