3 floors · 2 apartments · 3,205 sq ft · built 1931 · class S2 · owner of record: 995 Manhattan Ave Property Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-05-05 (Pre-filing). Agency page | Dec 31, 2026 in 64 days | 1 of 1 without an accepted 2026 report yet |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 308 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 795 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 28, 2026 | Construction CLASS - 1 OBSERVED PIECES OF SIDING MISSING LOOSE AT EXPOSURE#4 AND SOME PART OPEN EXPOSED TO THE ELEMENTS. WHOLE FACADE AT EXPOSURE #4 IN DESREPAIR, REPAIR AND/REPLACE #39205873L | Dec 2, 2026 PENDING | $2,500 |
| Jul 16, 2026 | Unknown CLASS - 1 SUPPORTED SCAFFOLD BC3314.1.@ACTIVE SITE OBSERVE UNSAFE 3FRAME WIDE X 4FRAME HIGH SUPPORTED SCAFFOLD @EXP3 YARD WITH LOOSE PLANKS THROUGHOUT W/ WORKER ON UPPERMOST PLANKS PERFORM EXTERIOR OPERATIONS WITHOUT FUL #39556673L | Sep 23, 2026 IN VIOLATION | $5,000 |
| May 29, 2026 | Unknown CLASS - 2 3303.7 FIRE PREVENTION AND FIRE PROTECTION. AT TIME OF INSPECTION OBSERVED STRUCTURAL WORK IN PROGRESS USING ELECTRICAL TOOLS, UPON WALKING THROUGHOUT JOB SITE ALL FLOORS NO FIRE EXTINGUISHERS AND NO SMOKING SI #39554768P | Jul 8, 2027 DEFAULT | $5,000 |
| May 29, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION OBSERVED: STRUCTURAL WORK AND GARBAGE REMOVAL IN PROGRESS 7 WORKERS ON SITE. UPON WALKING THROUGHOUT ENTIRE JOB SITE, NO SANITARY FACILITY PROVIDED, CONTRARY TO BC 3303.2.4 CREATING A SANI #39554769R | Jul 8, 2027 DEFAULT | $5,000 |
| May 29, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED: STRUCTURAL WORK CONTRARY TO APPROVED DRAWINGS. A-100.00. STEEL RIDGE BEAM 10X4 AT MAIN ROOF INSTALLED NO SHOWING ON DRAWINGS. CREATING AN UNSAFE VIOLATION CONDITION FOR SAFETY MO #39554767N | Jul 8, 2027 DEFAULT | $3,125 |
| May 15, 2026 | Construction CLASS - 2 OBSERVED VIEW PANELS ON FENCE ON HURAN ST WITHOUT COVER MISSING NONFRANGIBLE ACRYLIC PANELING OR EQUIVALENT COVERS (BC 3307.7.3). NEGLIGENCE OF MAINTENANCE WELCOMED POTENTIAL HAZARD ACCUMULATION AND VANDALISM. #39554174H | Jul 22, 2026 DEFAULT | $2,500 |
| Mar 11, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION OBSERVED AT EXPO# 2 CONTAINER DEBRIS FULLY OVERLOADED NO COVERED CONTRARY TO BC 3303.4.2 AROUND 7:35 AM NO CONSTRUCTION ACTIVITIES, CREATING A POTENTIAL SAFETY HAZARDOUS CONDITION, SHARP M #39551477L | Mar 23, 2027 DEFAULT | $2,530 |
| Nov 28, 2025 | Construction CLASS - 2 RESPONDING A COMPLAINT OBSERVED: SIDEWALK SHED INSTALLED AT EXPO# 1-2. NO UNDERSIDE LIGHTING INOPERABLE LIGHT BULBS, FAILURE TO MAINTAIN AS PER CODE 3307.6.4.8 BECOME AN UNSAFE AND HAZARDOUS CONDITION FOR PEDES #39547406M | Feb 9, 2027 DEFAULT | $5,000 |
| Issued | Violation | Status |
|---|---|---|
| Nov 10, 2025 | CONSTRUCTION EMERGENCY WORK ORDER.FIRE DMG ON THE 1STRY REAR EXTENSION OF THE BLDG@ EXP3.1STFL JOISTS THE 1STRY EXTENSION WERE SEVERELY CHARRED&ROOF OF THE EXTENSN WAS PRTLLY OPEN.BRKN GLASS PIECES OF WNDW ON EXP1.OWNR TO IMMED INSTLL SDWLK SHED ALNG THE ENT EXP1 ON MANHATTAN AVE AND EXPOSURE 2 ON HURON STREET #FEU30102BP | DOB VIOLATION - ACTIVE |
| Nov 10, 2025 | CONSTRUCTION EMERGENCY WORK ORDER.1STRY EXTSN@REAR WAS DMGD BY FIRE ON 11/9/25.2ND FL EXP3 WOOD SPANDREL SEVERELY CHARRD.ROOF FRAMNG&THE 1STRY EXTNSN @ EXP3 SEVERELY CHARRD.3RDFL BALCNY@EXP3 WAS SPPRTD ON THE CMPRMSD.UNDR DRCT&CNTINUOUS SPRVSN OF PE IMMED:1.DEMO THE EXP3 BALCNY &SEAL ALL DOORS LEADNG TO THE BLCN #FEU30103BP | DOB VIOLATION - ACTIVE |
| Nov 9, 2025 | CONSTRUCTION DAMAGE TO BUILDING FROM FIRE ON LEVELS 1- 3 STRUCTURAL DAMAGE TO WOOD FRAME OF BUILDING FROM FIRE AND WATER, ROOF IS OPEN. BUILDING IS NON CODE COMPLAINT #25-02525 | DOB VIOLATION - ACTIVE |
| Nov 9, 2025 | CONSTRUCTION DAMAGE TO BUILDING FROM FIRE ON LEVELS 1-3 STRUTURAL DAMAGE TO WOOD FR AME OF BUILDING FROM FIRE AND WATER OWNWER TO HIRE NYSPE TO SUBMIT REPORT WITH PLANS ,PHOTOS AND REPAIR PA LS TO ERTINSPECTIONS@BUILDINGS.NYC.GOV 718-286-3460 WITHIN 7 DAYS #CER02EB | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Aug 19, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 21, 2025 | I | § 27-2142 ADM CODE - THE PREMISES OR APTS. HAVE BEEN VACATED BY THE DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APT. #2, 1ST APT. FROM WEST AT NORTH ON 2ND STORY, AND APT. #3, 1ST APT. FROM WEST AT NORTH ON 3RD STORY. VACATE ORDER #260136 POSTED. | — |
| Nov 20, 2025 | C | Apt 2 · § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 26, 2025 |
| Nov 20, 2025 | C | Apt 3 · § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 26, 2025 |
| Nov 20, 2025 | B | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING, AND ALL WALLS AT PUBLIC HALL, 2nd STORY | Dec 25, 2025 |
| Nov 20, 2025 | B | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING, NORTH AND SOUTH WALLS AT PUBLIC HALL, 3rd STORY | Dec 25, 2025 |
| Nov 20, 2025 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANES AT SKYLIGHT AT ROOF , 3rd STORY | Nov 26, 2025 |
| Nov 20, 2025 | B | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING, WEST AND NORTH WALLS AT PUBLIC HALL, 1st STORY | Dec 25, 2025 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 28, 2026 | ECB | Construction: OBSERVED PIECES OF SIDING MISSING LOOSE AT EXPOSURE#4 AND SOME PART OPEN EXPOSED TO THE ELEMENTS. WHOLE FACADE AT EXPOSURE #4 IN DESREPAIR, REPAIR AND/REPLACE | Open |
| Aug 19, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 16, 2026 | ECB | Unknown: SUPPORTED SCAFFOLD BC3314.1.@ACTIVE SITE OBSERVE UNSAFE 3FRAME WIDE X 4FRAME HIGH SUPPORTED SCAFFOLD @EXP3 YARD WITH LOOSE PLANKS THROUGHOUT W/ WORKER ON UPPERMOST PLANKS PERFORM EXTERIOR OPERATIONS WITHOUT FUL | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 28, 2026, 9:28 AM ET. BBL 3025220047.