Manhattan · Block 53 · Lot 2 · 10006

99 Washington Street

50 floors · 142,236 sq ft · built 2012 · class H2 · owner of record: 99 Washington Owner, Llc

7open violations
$25,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
58dto Annual boiler inspection (5 boilers)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 58 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (5 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-04 (Accepted). Agency page

Dec 31, 2026
in 58 days
5 of 5 without an accepted 2026 report yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 142,236 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 179 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 179 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 789 days
Next cycle year 2028
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page

Feb 21, 2029
in 841 days
Filing window not open yet
Energy audit and retro-commissioning (2033) Likely applies
Local Law 87 · Calendar year 2033
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 53). Agency page

Dec 31, 2033
in 2615 days
Next due 2033

Open violations

ECB / OATH (1) · $25,000 owed
IssuedViolationHearingBalance
Mar 10, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTIONM I OBSERVED AT EXP #3 EAST-A SECTION OF ALUMINUM TRIM WITH ASSOCIATED GASLIT AT THE ALUMINUM FACADE PANEL JOINT WAS LOOSE/
#35726993Y
May 14, 2026
DEFAULT
$25,000
DOB (5)
IssuedViolationStatus
Mar 10, 2026CONSTRUCTION
EWO DUE TO LOOSE/PARTIALLY DETACHED ALUMINUM STRIP W/ASSOCIATED GASKET @ EXP3 EAST AT 40FL, CREATING A POTENTIAL MATERIAL FALLING HAZARD REMEDY: IMMEDIATELY TAKE/PROVIDE ADEQUATE SAFETY MEASURES TO SECURE/ PROTECT PUBLIC @ EXP#3 EAST.ADDITIONALLY REMOVE ALL LOOSE MATERIAL AND & REPAIR DEFECTIVE FACA
#FA0101DD
DOB VIOLATION - ACTIVE
Mar 11, 2025CONSTRUCTION
FAILURE TO MAINTAIN FACADE & APPURTANCES DUE TO 2 MISSING PANELS NW CORN EXP#2N & LOOSE GASKETS PROTRUDING FROM BETWEEN METAL PANELS @EXP3 E MULT LOC. REMEDY:RETAIN SERVICES OF NYS RDP W/QEWI CERT & ALUM FACAD PANELS. INSTALL PUBL PROTECTION @ ALL REQUIRED LOCS TO PROTECT PUBLIC SUBMIT FULL REPORT T
#FA0101DD
DOB VIOLATION - ACTIVE
Feb 1, 2025CONSTRUCTION
AT TIME OF INSPECTION OBSERVED AT EXP#2 MISSING METAL PANEL FROM FACADE.
#25-00189
DOB VIOLATION - ACTIVE
Dec 31, 2013NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013
#00369
DOB VIOLATION - ACTIVE
Oct 25, 2007CONSTRUCTION

#01AW01
VIOLATION WORK WITHOUT PERMIT - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Aug 31, 2026AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Aug 31, 2026DOB SafetyAEUHAZ: Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 3, 2026, 10:18 AM ET. BBL 1000530002.