3 floors · 3 apartments · 2,006 sq ft · built 2007 · class C0 · owner of record: Epstein, Herman
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 778 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 17, 2024 | Construction CLASS - 1 REMOVED OR DEFACED A WRITTEN POSTED VACATE ORDER. NOTED A WRITTEN POSTED VACATE ORDER #B420/2011 ISSUED ON 11/22/2011 HAS BEEN REMOVED FROM THE MAIN ENTRY DOOR(FIRST AND THIRD FLOOR). REMEDY: COMPLY WITH CODE. #35681544M | Jan 5, 2026 IN VIOLATION | $2,500 |
| Oct 17, 2024 | Construction CLASS - 1 REMOVED OE DEFACED A WRITTEN POSTED VACATE ORDER. NOTED A WRITTEN POSTED VACATE ORDER #B420/2012 ISSUED ON 12/20/2012 HAS BEEM REMOVED FROM THE MAIN ENTRY DOOR(FOR CELLAR LEVEL). REMEDY: COMPLY WITH CODE. #35681543K | Jan 5, 2026 IN VIOLATION | $2,500 |
| Jul 19, 2018 | Construction CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35330983J ISSUED ON 04-30-18 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. FOR STORING COMBUSTIBLE MATERIAL IN THE CORRIDOR. REMEDY: COMPL #35341378P | Mar 29, 2019 IN VIOLATION | $625 |
| Jul 19, 2018 | Construction CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35330982H ISSUED ON 04-30-18 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. FOR OBSTRUCTING THE CORRIDOR W/WOOD & STORING PAINT TINNER. #35341377N | Mar 29, 2019 IN VIOLATION | $625 |
| Apr 30, 2018 | Construction CLASS - 1 REISSUE #35272535N ISSUE 08/18/2017.UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT.NOTE:AT FIRST FLOOR CORRIDOR STORING OF PARTS AND PAINT THINNER, WOOD AND OTHER COMBUSTIBLE MATERIALS.REM:MAINTAIN STORAG #35330983J | Mar 29, 2019 IN VIOLATION | $781 |
| Apr 30, 2018 | Construction CLASS - 1 REISSUE #35272536P ISSUE 8/16/2017.FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTE:AT TIME OF INSPECTION.AT ENTRY TO MUTIPLE DWELLING AT CORRIDOR AREA STORING PAINT THINNER AND WOOD AND OTHER BUILDING MATE #35330982H | Mar 29, 2019 IN VIOLATION | $781 |
| Dec 20, 2012 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O #30230836 ILLEGAL OCCUPANCY NOTED: CELLAR (OPEN) CONVERTED INTO CLASS'A' APT 1 BEDROOM. PREVIOUS VIOLATION #34924205P. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY. #35006674L | Nov 25, 2013 WRITTEN OFF | $0 |
| Dec 20, 2012 | Construction CLASS - 1 WORK W/O PERMIT. WORK NOTED: AT CELLAR LEVEL ERECT FULL HEIGHT PARTITION & WATER & WASTE LINES TO CREATE CLASS'A' APT 1 BEDROOM. WORK 100% COMPLETE. REMEDY: STOP ALL WORK. OBTAIN PERMIT. #35006701H | Dec 5, 2013 WRITTEN OFF | $0 |
| Dec 20, 2012 | Construction CLASS - 1 SEC. 1001.4 INADEQUATE EXITS FOR EXISTING STRUCTURES. FAILURE TO PROVIDE 2 MEANS OF EGRESS FROM ROOM ON SPACE WHERE REQUIRED. FOR CELLAR LEVEL APT. PREVIOUS VIOLATION #34924208K. REMEDY: DISCONTINUE ILLEGAL OCC #35006700X | Dec 5, 2013 WRITTEN OFF | $0 |
| Nov 23, 2011 | Construction CLASS - 1 2ND FL APT HAVING ERECTED FULL HEIGHT PARTITION IN LIVING ROOM TO CREATE ADDITIONAL BDRM IN FRONT ALL WORK COMPLETED W/O FIRST OBTAINING DOB PERMIT REM: STOP ALL WORK OBTAIN PERMIT #34924253J | Mar 17, 2014 WRITTEN OFF | $0 |
| Nov 23, 2011 | Construction CLASS - 1 FAILURE TO PROVIDE EXIT SIGN WHERE REQUIRED FOR EXITS AND EXITS DOORS NOTED BLDG OCCUPIED AS TRANSIENT USE W/O EXIT SIGNS REM: PROVIDE EXIT SIGNS #34924224K | Jun 17, 2013 WRITTEN OFF | $0 |
| Nov 23, 2011 | Construction CLASS - 1 BC1008.12.2 FAILURE TO COMPLY W/ DIRECTION OF SUING NOTED FIRST FL PRIMARY EXIT DOOR ENTRANCE DOOR TO THE STREET SUING AGAINST THE DIRECTIONOF EGRESS TRAVEL IN TRANSIENT USE BLDG REM: CONFORM DOOR SUING W/ DIRE #34924223Z | Dec 17, 2012 WRITTEN OFF | $0 |
| Nov 23, 2011 | Construction CLASS - 2 ILLEGAL USE IN RESIDENTIAL DISTRICT NOTED BLDG OCCUPIED AS TRANSIENT USE IN R6 GENERAL RESIDENCE DISTRICT AND C1-3 LOCAL RETAIL DISTRICT FOR COMMERCIAL OVERLAY REM: DISCONTINUE ILLEGAL USE #34924222R | Mar 17, 2014 WRITTEN OFF | $0 |
| Nov 23, 2011 | Construction CLASS - 1 INADEQUATE EXITS FOR EXISITING STRUCTURES FAILURE TO PROVIDE TWO MEANS OF EGRESS FROM ROOM OR SPACE WHERE REQUIRED NOTED ALL ROOMS IN APT #2 ON 2ND FL OCCUPIED AS TRANSIENT USE W/O PROVIDEING TWO MEANS OF EGRES #34924220N | Dec 17, 2012 WRITTEN OFF | $0 |
| Nov 23, 2011 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER ILLUMINATION FOR EXITS EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC1006.1 27-381 NOTED BLDG OCCUPIED AS TRANSIENT USE W/O PROVIDING EMERGENCY LIGHTS REM: PROVIDE #34924251X | Mar 17, 2014 WRITTEN OFF | $0 |
| Nov 23, 2011 | Construction CLASS - 1 NOTED 2ND FL APT #2 OCCUPIED AS TRANSIENT USE CONTRARY TO C/O #302308036 DATED 6/17/08 WHICH INDICATES DWELLING UNITS REM: DISCONTINUE ILLEGAL OCCUPANCY #34924219X | Mar 18, 2013 WRITTEN OFF | $0 |
| Nov 23, 2011 | Construction CLASS - 1 BC1004.1.2 FAILURE TO COMPLY W/ MAXIMUM FLOOR AREA REQUIREMENTS PER OCCUPANT LOAD AS PER BC 1004.12 TABLE 1004.12 NOTED 2ND FL APT #2 OCCUPIED AS TRANSIENT USE AND BEING OCCUPIED BY UP TO 4 OCCUPANTS ON TWO BUN #34924221P | Mar 25, 2013 WRITTEN OFF | $0 |
| Nov 23, 2011 | Construction CLASS - 1 BC907.2.8 FAILURE TO PROVIDE FIRE ALARM SYSTEM NOTED BLDG OCCUPIED AS TRANSIENT USE W/O FIRE ALARM SYSTEM REM: PROVIDE FIRE ALARM SYSTEM #34924250Y | Mar 17, 2014 WRITTEN OFF | $0 |
| Nov 23, 2011 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY NOTED FIRST FLOOR EXIT PASSAGEWAY CORRIDOR OBSTRUCTED BY STORED WASH & DRYER MACHINE KTCN STOVE & 4'X8' DRYWALL BOARDS REM; REMOVE OBSTRUCTION FORTHWITH #34924252H | Mar 17, 2014 WRITTEN OFF | $0 |
| Nov 22, 2011 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C/O. ILLEGAL OCCUPANCY NOTED: BLDG OCCUPIED ON 1ST FLR AND 3RD FLR APTS AS SROS. CONTRARY TO C/O #302308036 DATED 6.17.08 WHICH INDICATES DWELLING UNITS. REMEDY: #34924205P | Jun 17, 2013 WRITTEN OFF | $0 |
| Nov 22, 2011 | Construction CLASS - 1 SEC. 1009.11. FAILURE TO PROVIDE HANDRAIL FOR STAIRWAYS. NOTED: MISSING HANDRAIL AT 2ND FLR LEVEL PUBLIC STAIRS. REMEDY: PROVIDE HANDRAIL FORTHWITH. #34924215Z | May 7, 2012 WRITTEN OFF | $0 |
| Nov 22, 2011 | Construction CLASS - 2 SEC. 907.2.8.3. FAILURE TO PROVIDE SMOKE DETECTORS W/I DWELLING UNITS.NOTED: 1ST FLR APT OCCUPIED AS DWELLING HAS MISSING SMOKE DETECTOR. REMEDY: PROVIDE SMOKE-CARBON MONOXIDE DETECTOR. #34924217M | Dec 17, 2012 WRITTEN OFF | $0 |
| Nov 22, 2011 | Construction CLASS - 1 SEC. 903.2.7. FAILURE TO PROVIDE AN AUTOMATIC SPRINKLER SYSTEM. NOTED:BLDG OCCUPIED AS SROS IN APT ON 1ST FLR AND 3RD FLR W/O PROVIDING SPRINKLER SYSTEM IN EACH SRO. REMEDY: PROVIDE SPRINKLER SYSTEM FOR SROS. #34924207Z | Jun 17, 2013 WRITTEN OFF | $0 |
| Nov 22, 2011 | Construction CLASS - 1 SEC. 1001.4. INADEQUATE EXITS FOR EXISTING STRUCTURES. FAILURE TO PROVIDE 2 MEANS OF EGRESS FROM ROOM OR SPACE WHERE REQUIRED. NOTED: BLDG HAVING OCCUPIED 1ST FLR,3RD FLR % MEZZANINE OF 3RD FLR - 4TH FLR LEVEL #34924208K | Dec 17, 2012 WRITTEN OFF | $0 |
| Nov 22, 2011 | Construction CLASS - 1 SEC. 1004.1.2. FAILURE TO COMPLY W/MAXIMUM FLR AREA REQUIREMENTS. PER OCCUPANT C/O AS PER BC 1004.1.2 - TABLE 1004.1.2. NOTED: BLDG OCCUPIED1ST FLR APT AS SROS BEING OCCUPIED BY UP TO 4 OCCUPANTS ON 2 BUNKBEDS #34924206R | Dec 17, 2012 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Mar 13, 2013 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00160 | DOB VIOLATION - ACTIVE |
| Mar 13, 2013 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00161 | DOB VIOLATION - ACTIVE |
| Mar 13, 2013 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00162 | DOB VIOLATION - ACTIVE |
| Feb 22, 2012 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00242 | DOB VIOLATION - ACTIVE |
| Feb 22, 2012 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00235 | DOB VIOLATION - ACTIVE |
| Feb 22, 2012 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00244 | DOB VIOLATION - ACTIVE |
| Feb 22, 2012 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00236 | DOB VIOLATION - ACTIVE |
| Feb 22, 2012 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00240 | DOB VIOLATION - ACTIVE |
| Feb 22, 2012 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00238 | DOB VIOLATION - ACTIVE |
| Feb 22, 2012 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00239 | DOB VIOLATION - ACTIVE |
| Feb 22, 2012 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00243 | DOB VIOLATION - ACTIVE |
| Feb 22, 2012 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00246 | DOB VIOLATION - ACTIVE |
| Feb 22, 2012 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00233 | DOB VIOLATION - ACTIVE |
| Feb 22, 2012 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00245 | DOB VIOLATION - ACTIVE |
| Feb 22, 2012 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00241 | DOB VIOLATION - ACTIVE |
| Feb 22, 2012 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00234 | DOB VIOLATION - ACTIVE |
| Feb 22, 2012 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00237 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 13, 2013 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 13, 2013 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 13, 2013 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2012 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2012 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2012 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2012 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2012 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2012 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2012 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2012 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2012 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2012 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2012 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2012 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2012 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2012 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Mar 5, 2025 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM .. AT PUBLIC HALL, 1st STORY | Mar 11, 2025 |
| Mar 5, 2025 | C | Apt 2 · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 11, 2025 |
| Mar 5, 2025 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM ... | Mar 11, 2025 |
| Mar 5, 2025 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY | Mar 11, 2025 |
| Mar 5, 2025 | C | Apt 2 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, APARTMENT AT WEST | Mar 11, 2025 |
| Dec 1, 2020 | B | Apt 1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPRX. 3 SQ. FEET IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 13748693 ISSUED 31-JUL-20 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3 | Jan 5, 2021 |
| Aug 3, 2020 | B | Apt 1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPRX. 10 SQ, FEET IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 7, 2020 |
| Jun 11, 2020 | C | Apt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 7, 2020 |
| Jun 11, 2020 | C | Apt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 7, 2020 |
| Sep 24, 2015 | B | Apt 2FL · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY | Oct 29, 2015 |
| Sep 24, 2015 | B | Apt 2FL · SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING APPROX. 15 SQUARE FEET IN THE BATHROOM LOCATED AT APT 2FL, 2nd STORY | Oct 29, 2015 |
| Sep 24, 2015 | B | Apt 2FL · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY | Oct 29, 2015 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 2:51 AM ET. BBL 3017430076.