3 floors · 7 apartments · 5,250 sq ft · built 1931 · class C1 · owner of record: Reinoso, Angel
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 70 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 70 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 86 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-09 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 7, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES FOR 39175459L. OBSERVED AT EXP 3/4 REAR YARD, A CONCRETE RETAINING WALL IN A STATE OF DISREPAIR WITH ITS TOP PORTION REMOVED, BUT THE BOTTOM PORTION HAS SEV #39199777N | Dec 29, 2026 PENDING | $12,500 |
| Jan 28, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED COMBUSTIBLE WOODEN CANOPY, BARBECUE GRILL AND OTHER HOUSEHOLD ITEMS HAVE BEEN HAZARDOUSLY PLACED UNDER THE FIRE ESCAPE (DROP LADDER) AT REAR OF TH #39175269K | Sep 2, 2026 IN VIOLATION | $2,500 |
| Jan 28, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTE: OBSERVED USE OF PROHIBITED DOOR AND/OR HARDWARE, TURN KNOB HAS BEEN INSTALLED ON TWO METAL DOORS ON EGRESS PASSAGEWAY (EAST SIDE OF BUILDING) RESTRIC #39175270H | Sep 2, 2026 IN VIOLATION | $2,500 |
| Jan 28, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTE: OBSERVED CONCRETE RETAINING WALL APPROX. 6 FT IN HEIGHT AND 20 LINEAR FT , IN A STATE OF COMPLETE DISREPAIR, BROKEN WITH SEVERE CRACKS AND, HAZARDOUS #39175459L | Sep 2, 2026 IN VIOLATION | $5,000 |
| Mar 27, 2008 | Quality of Life Non-Hazardous RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED NUMBER OF FAMILIES DOB RECORDS INDICATES RESIDENCE TO BE LEGALLY APPROVED FOR A 7 FAMILY RESIDENCE IS NOW ALTERED FOR OCCUPANCY #34641495M | May 27, 2008 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jan 28, 2026 | CONSTRUCTION OBSERVED CONCRETE RETAINING WALL APPROX. 6 FT IN HEIGHT AND 20 LINEAR FT , IN A STATE OF COMPLETE DISREPAIR, BROKEN WITH SEVERE CRACKS AND, HAZARDOUSLY LEANING WITH POTENTIAL TO COLLAPSE ONTO THE BACK YARD REAR EXPOSURE 4 AT THIS LOCATION. #26-00379 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #15263 | DOB VIOLATION - ACTIVE |
| Feb 24, 2017 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT #16121 | DOB VIOLATION - ACTIVE |
| Dec 13, 2011 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT #18547 | DOB VIOLATION - ACTIVE |
| Dec 31, 2009 | LOW PRESSURE BOILER #21563 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 4) | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Feb 24, 2017 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT | Active |
| Dec 13, 2011 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT | Active |
| Dec 31, 2009 | Boiler LBLVIO | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 6, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 9, 2026 |
| Dec 10, 2019 | C | Apt 6 · § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Dec 31, 2019 |
| Dec 10, 2019 | C | Apt 6 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Dec 31, 2019 |
| Dec 10, 2019 | C | Apt 6 · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 5; WG TO REPLACE = 1; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 6, 3rd STORY, 1st APAR | Jan 7, 2020 |
| Dec 10, 2019 | A | Apt 6 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 14, 2020 |
| Jun 10, 2015 | B | Apt 1 · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY | Jul 15, 2015 |
| Jun 10, 2015 | B | Apt 1 · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, APARTMENT AT WEST | Jul 15, 2015 |
| Jun 10, 2015 | B | Apt 1 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING AT CLOSET IN THE 1st ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, APARTMENT AT WEST | Jul 15, 2015 |
| Jun 10, 2015 | B | Apt 1 · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE GAS RANGE'S PILOT LIGHT IN THE KITCHEN LOCATED AT APT 1, 1st STORY, APARTMENT AT WEST | Jul 15, 2015 |
| Jun 10, 2015 | A | SECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR , AT PUBLIC HALL, 1st STORY | Sep 13, 2015 |
| Jun 10, 2015 | A | SECTION 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY | Sep 13, 2015 |
| Jun 10, 2015 | A | SECTION 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCY?S HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Sep 13, 2015 |
| Jun 10, 2015 | A | SECTION 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY | Sep 13, 2015 |
| Jun 10, 2015 | B | Apt 1 · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DOOR CASING IN THE BATHROOM LOCATED AT APT 1, 1st STORY | Jul 15, 2015 |
| Jun 10, 2015 | B | Apt 1 · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW COUNTER BALANCE LOWER SASH IN THE BATHROOM LOCATED AT APT 1, 1st STORY | Jul 15, 2015 |
| Jun 10, 2015 | B | Apt 1 · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD CABINET AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 1, 1st STORY | Jul 15, 2015 |
| Jun 10, 2015 | B | Apt 1 · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILE IN THE BATHROOM LOCATED AT APT 1, 1st STORY | Jul 15, 2015 |
| Jun 10, 2015 | B | Apt 1 · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE SADDLE IN THE BATHROOM LOCATED AT APT 1, 1st STORY | Jul 15, 2015 |
| Aug 14, 2008 | B | D26-11.01, 11.03, 11.05 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CELLAR THRUOUT. | Sep 18, 2008 |
| Aug 14, 2008 | A | Apt 5 · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY ENTRANCE DOOR 3 STY FRONT APT 5. , SECTION '' '' | Nov 17, 2008 |
| Aug 14, 2008 | A | SECTION 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX SIGN MISSING. | Nov 17, 2008 |
| Sep 10, 2007 | A | SECTION 62 M/D LAW REARRANGE TELEVISION AND/OR RADIO ANTENNA TO BE AT LEAST 10 FEET ABOVE ROOF AND NOT ATTACHED TO ANY FIRE ESCAPE OR SOIL OR VENT LINE ROOF CENTER . | Dec 14, 2007 |
| Sep 10, 2007 | A | Apt 5 · SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DROP CEILING CENTER ROOM 3 STY APT 5. LOCATED AT APT 5 | Dec 14, 2007 |
| Sep 10, 2007 | C | Apt 5 · SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED AT ENTRANCE DOOR TO 3 STY APT 5. , SECTION '' '' | Sep 16, 2007 |
| Date | Source | What | Now |
|---|---|---|---|
| Aug 7, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES FOR 39175459L. OBSERVED AT EXP 3/4 REAR YARD, A CONCRETE RETAINING WALL IN A STATE OF DISREPAIR WITH ITS TOP PORTION REMOVED, BUT THE BOTTOM PORTION HAS SEV | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 22, 2026, 12:28 PM ET. BBL 4016160010.