3 floors · 2 apartments · 3,216 sq ft · built 1930 · class S9 · owner of record: Meza, Luis
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 62 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 62 days | Keep the report on file (not filed with DOB) |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 306 days | Required only if the owner doesn't live there |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 17, 2026 | Construction CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER. DOB PARAPET VIO #082726PI30806SB AND DOB CONTROL #370420 DATED 08-27-2026. NO COMPLIANCE ONFILE FOR ANNUAL PARAPET OBSERVATION REPORT. REMEDY: COMPLY WITH THE CO #35733191H | Dec 9, 2026 PENDING | $2,500 |
| Aug 27, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. PROPERTY IS AN ATTACHED 3+C MIXED USE DWELLING LOCATED ON A CORNER LOT. OBSERVED ATEXPOSURES 1 AND 4 DETERIORATED MORTAR JOINTS UNDER 3RD FLOOR WINDOWS, #35718654J | Nov 4, 2026 PENDING | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Aug 27, 2026 | CONSTRUCTION FTM BLDG IN A CODE COMPLIANT MANNER-OBSVD @ EXP4 AT 501 GRAND AVE SEVERAL LOOSE/BULGING BRICKS NEAR EXP3/4 PARAPET. AN ANNUAL PARAPET OBSERVATION REPORT IS REQ'D TO BE COMPLETED ANNUALLY STARTING IN 2024 SUBMIT ANNUAL PARAPET OBSERVATION REPORT FOR 2025 TO BE REC'D NO LATER THAN 9/10/2026 #PI30806SB | DOB VIOLATION - ACTIVE |
| Aug 27, 2026 | CONSTRUCTION CORRECTIVE ACTION PLAN REQ'D-OBSVD DETERIORATED MORTAR JOINTS AT EXP1& 4 UNDER 3FL WINDOW & A BRICK STEP CRACK UNDER 3FL WINDOW. @ EXP4 OF 501 GRAND AVE OBSVD SEVERLY LOOSE/BULGING BRICKS NEAR 3/4 CORNER OWNER TO IMMED RETIN REG DESIGN PROF IN GOOD STANDING W/DOB&NYS TO EVAL ENTIRE BLDG & SUBMIT A C #PI30804SB | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 7, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 5, 2018 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL FASAD AT SOUTH SIDE OF BUILDING | Dec 10, 2018 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 7, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 17, 2026 | ECB | Construction: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER. DOB PARAPET VIO #082726PI30806SB AND DOB CONTROL #370420 DATED 08-27-2026. NO COMPLIANCE ONFILE FOR ANNUAL PARAPET OBSERVATION REPORT. REMEDY: COMPLY WITH THE CO | Open |
| Aug 27, 2026 | DOB | CONSTRUCTION: FTM BLDG IN A CODE COMPLIANT MANNER-OBSVD @ EXP4 AT 501 GRAND AVE SEVERAL LOOSE/BULGING BRICKS NEAR EXP3/4 PARAPET. AN ANNUAL PARAPET OBSERVATION REPORT IS REQ'D TO BE COMPLETED ANNUALLY STARTING IN 2024 SUBMIT ANNUAL PARAPET OBSERVATION REPORT FOR 2025 TO BE REC'D NO LATER THAN 9/10/2026 | Open |
| Aug 27, 2026 | DOB | CONSTRUCTION: CORRECTIVE ACTION PLAN REQ'D-OBSVD DETERIORATED MORTAR JOINTS AT EXP1& 4 UNDER 3FL WINDOW & A BRICK STEP CRACK UNDER 3FL WINDOW. @ EXP4 OF 501 GRAND AVE OBSVD SEVERLY LOOSE/BULGING BRICKS NEAR 3/4 CORNER OWNER TO IMMED RETIN REG DESIGN PROF IN GOOD STANDING W/DOB&NYS TO EVAL ENTIRE BLDG & SUBMIT A C | Open |
| Aug 27, 2026 | DOB | CONSTRUCTION: EMERGENCY WORK ORDER REQ'D-AT EXP4 AT 501 GRAND AVE OBSVD SEVERLY LOOSE/BULGING BRIKCS @ PARAPET NEAR 3/4 CORNER & SEVERAL OTHER AREAS OF CRACKED/SPALLING MASONRY. THESE CONDITIONS ARE UNSTALBE & AT RISK OF COLLAPSE.OWNER TO IMMED RETAIN DOB REG GC TO INSTALL S/W SHED @ EXP4 AT 501 GRAND AVE APPROX | Closed |
| Aug 27, 2026 | DOB | CONSTRUCTION: EMERGENCY WORK ORDER REQ'D-OBSVD SEVERLY LOOSE/BULGING BRICKS @ PARAPET NEAR 3/4 CORNER & SEVERAL OTHER AREAS OF CRACKED/SPALLING MASONRY. THE CONDITIONS ARE UNSTABLE & AT RISK OF COLLAPSE ONTO THE PUBLIC WAY. OWNER TO IMMED PROVIDE TEMP STABILIZATION FOR THE MASONRY ROOF PARAPET AT THE EXP3/4 CORNE | Closed |
| Aug 27, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. PROPERTY IS AN ATTACHED 3+C MIXED USE DWELLING LOCATED ON A CORNER LOT. OBSERVED ATEXPOSURES 1 AND 4 DETERIORATED MORTAR JOINTS UNDER 3RD FLOOR WINDOWS, | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 30, 2026, 10:15 PM ET. BBL 3011250004.