6 floors · 26 apartments · 27,126 sq ft · built 1927 · class D1 · owner of record: Bec Continuum Housing Development Fund C Ompany Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 69 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 69 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 69 days | Annual |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-12 (Accepted). Agency page | Dec 31, 2026 in 69 days | 1 of 2 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 85 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 27,126 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 190 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 190 days | Annual filing |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 3, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, APPROVED DRAWINGS REQUIRED THE SIDEWALK SHED RIGHT-ANGLE CLAMP TO BE SECURED TO THE GROUND WITH A 3/4-INCH HILTI ANCHOR BOLT. REQUIRED ANCHORAGE WAS NOT INSTALLED, COMPROMISING THE APPROV #39557430L | Oct 7, 2026 DEFAULT | $1,280 |
| Aug 3, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, SIDEWALK SHED WAS NOT MAINTAINED. DETERIORATED MUD SILLS HAD SETTLED UNDER THE SHED LOAD CREATING POSSIBLE DISLODGEMENT. SHORING WAS NOT SECURED TO THE MUD SILLS, AND TWO SHORING POSTS WE #39557429Y | Oct 7, 2026 DEFAULT | $2,430 |
| Jun 5, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION, OBSERVED A SIDEWALK SHED INSTALLED AT THE PREMISES. UPON REVIEW OF DEPARTMENT RECORDS, NO ELECTRICAL PERMIT WAS FOUND ON FILE FOR THE SIDEWALK SHED WIRING AND LIGHTING INSTALLATION. THIS #39555113Z | Aug 12, 2026 DEFAULT | $12,500 |
| Apr 20, 2026 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A AND 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #916465. AGG1: PRIOR NOV 37026400P UNDER #37036622J | Jul 22, 2026 IN VIOLATION | $0 |
| Sep 29, 2025 | Elevators CLASS - 2 MISSING MACHINE ROOM VENTILATION PER K3. MISALIGNED CAB MIRROR. CLEAN PIT. #39161806J | Nov 17, 2026 DEFAULT | $655 |
| Sep 23, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR FACADE AND APPURTENANCES. AT TIME OF INSPECTION OBSERVED STEP CRACK AT EXPOSURE #1(SOUTH) ROOF LEVEL. CRACKS ONSTUCCO AT EXPOSURES #2(WEST ELEVATION) AND #3(NORTH ELEVATION) AT MULT #35694099X | Nov 16, 2026 DEFAULT | $10,000 |
| Sep 9, 2025 | Unknown CLASS - 2 OBSERVED AT EXPOSURE #1 THE SIDEWALK SHED IS INSTALLED AND BLOCKING THE EGRESS/INGRESS OF THE BUILDINGS FIRE ESCAPE. CREATING VERY UNSAFE CONDITIONS FOR TENANTS INCASE OF AN EMERGENCY OR FIRE. B.C 3307.6.4.9 SI #39544635M | Nov 19, 2025 DEFAULT | $10,000 |
| Sep 9, 2025 | Construction CLASS - 2 SHED INSTALLED FOR FACADE WORK. WHILE INSPECTING SHED CONDITIONS I OBSERVED IN MULTIPLE LOCATIONS THE VERTICAL MEMBERS OF THE SHED ARE RESTING ON DAMAGED/DETERIORATING MUD SILLS WHICH CREATES UNSAFE CONDITIONS #39544634K | Nov 19, 2025 DEFAULT | $10,000 |
| Jul 29, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTES:AT THE TIME OF INSPECTION OBSERVED AT EXPOSURE 2 AND 3 CRACK STUCCO ATMULTIPLE LOCATIONS. REMEDY: MAINTAIN EXTERIOR FACADE. TAKE SAFETY MEAS #35694087Z | Nov 3, 2025 IN VIOLATION | $2,500 |
| Dec 30, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: OBSERVED AT EXPOSURE 1 SOUTH ELEVATION, DAMAGED ROOF SHINGLES, AT EXPOSURE 2, 3, 4(WEST/NORTH; EAST ELEVATIONS) OBSERVED SPALLING/CRACKED MA #35689316R | Mar 5, 2025 STIPULATION/IN-VIO | $630 |
| Jan 16, 2024 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A & 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #916465.REMEDY:FILE ACCEPTABLE REPORT #37026400P | Apr 17, 2024 IN VIOLATION | $1,250 |
| May 6, 2023 | Construction CLASS - 2 AT TINE OF INSPECTION OBSERVED NUMEROUS UNSAFE CONDITIONS ON SIDEWALK SHED. SHARP EDGES ,LIGHT FIXTURES DETACHED FROM UNDERSIDE OF DECK, EXCESSIVE CONSTRUCTION MATERIAL AND DEBRIS ON TOP OF SIDEWALK SHED . SHED #39516247M | Jul 12, 2023 DEFAULT | $10,000 |
| Mar 1, 2018 | Construction CLASS - 1 FAILURE TO TAKE REQUIRED MEASURES TO SECURE PUBLIC SAFETY FROM UNSAE FACADE.NOTE:-EXPOSURE #2 WEST ELEVATION:CRACKS & STEP CRACK @ SEVERAL FLS IN STUCCO.W/NO SHED BELOW.(EXP #3) NORTH ELEVATION:CRACKS STEP SHED #35265396R | Jun 20, 2018 IN VIOLATION | $0 |
| Aug 30, 1999 | Local Law Non-Hazardous FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYINGTO THE INSTALLATION OF REQUIRED FIRE PROTECTION SYSTEMS REMEDY: FILE REPORT #34223329P | Oct 18, 1999 WRITTEN OFF | $0 |
| Aug 12, 1991 | Construction Hazardous FAILURE TO MAINTAIN DEFECT IS,REAR WALL NORTHEAST SIDE HAS VERTICAL AND DIAGONAL CRACKS APPROX 1/2"TO 1" WIDE TO 6'TO 10' LONG BET 5THAND6FLREMEDY REPAIR CRACKS TO THE SATISFACTION OF THIS DEPT AND SUBMIT AN EN #34060190X | Oct 28, 1991 WRITTEN OFF | $0 |
| Aug 12, 1991 | Construction Hazardous FAILURE TO MAINTAIN DEFECT IS; 2 FOOT LONG STRUCTURAL CRACK AT SOUTH EAST PARAPET WALL 1/2 TO 3/4 WIDE REMEDY - REPAIR CRACK TO THE SATISFACTION OF THIS DEPT AND SUBMIT ENGINER REPORT AS TO STRUCTUAL INTEGRITY #34060189Z | Oct 28, 1991 WRITTEN OFF | $0 |
| Sep 12, 1990 | Construction Hazardous FAILURE TO MAINTAIN. DEFECT IS: 2 FOOT LONG STRUCTURAL CRACK AT SOUTH EAST PARAPIT WALL APPROX. 1/2" TO 3/4" WIDE. REMEDY: REPAIR CRACK TO THE SATISFACTION OF THIS DEPT. AND SUBMIT ENGINEERS REPORT AS TO STRUCT #34043085J | Dec 10, 1990 WRITTEN OFF | $0 |
| Sep 12, 1990 | Construction Hazardous FAILURE TO MAINTAIN: DEFECT IS. REAR WALL NORTHEAST SIDE HAS VERTICAL AND DIAGONAL CRACKS APPROX. 1/2" TO 1" WIDE TO 6' TO 10' LONG BET 5TH AND 6TH FL. REMEDY: REPAIR CRACKS TO THE SATISFACTION OF THIS DEPT. #34043084H | Dec 10, 1990 WRITTEN OFF | $0 |
| Sep 21, 1989 | Construction Hazardous FAILURE TO MAINTAIN. REMEDY: MAKE REPAIRS TO THE SATISFACTION OF THIS DEPARTMENT. #34031368L | Nov 27, 1989 WRITTEN OFF | $0 |
| Sep 20, 1989 | Construction Hazardous FAILURE TO MAINTAIN. 2 FOOT LONG STRUCTURAL CRACK AT SOUTH EAST PARAPET WALL. REMEDY: REPAIR CRACK TO THE SATISFACTION OF THIS DEPARTMENT AND SUBMIT ENGINEERS REPORTS TO THIS DEPARTMENT. #34031365X | Nov 27, 1989 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #40131 | DOB VIOLATION - ACTIVE |
| Feb 17, 2021 | HAZARDOUS CONDITION (FACADE) CYCLE 8A UNSAFE REPORT FILED #809259 | DOB VIOLATION - ACTIVE |
| Feb 17, 2021 | HAZARDOUS CONDITION (FACADE) CYCLE 9A UNSAFE REPORT FILED #909260 | DOB VIOLATION - ACTIVE |
| May 31, 2018 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 #00883 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #38361 | DOB VIOLATION - ACTIVE |
| Aug 12, 1991 | CONSTRUCTION #08R08 | VIOLATION UNSERVED ECB-ACTIVE |
| Sep 12, 1990 | CONSTRUCTION #892VW | VIOLATION UNSERVED ECB-ACTIVE |
| Sep 12, 1990 | CONSTRUCTION #8P1VW | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 6, 2026 | Energy Grade - LL33 FTP-EN-EGRDEA FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER AD CODE SEC. 28-309.12.3 | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Feb 17, 2021 | Facades FISPHAZ CYCLE 8A UNSAFE REPORT FILED | Active |
| Feb 17, 2021 | Facades FISPHAZ CYCLE 9A UNSAFE REPORT FILED | Active |
| May 31, 2018 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 3, 2026 | C | Apt 6B · § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING KICKSTAND AT DOOR IN THE ENTRANCE LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 17, 2026 |
| Aug 26, 2026 | C | Apt 2E · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 9, 2026 |
| Aug 26, 2026 | C | Apt 1A · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SIDEWALK SCAFFOLD SHED BLOCKING ACCESS TO FIRE ESCAPE WINDOW IN THE 1st ROOM FROM EAST LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 1, 2026 |
| Jul 10, 2026 | C | Apt 1E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE LOWER WINDOW SASH AT 1ST WINDOW FROM EAST AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 16, 2026 |
| Jul 1, 2026 | A | Apt 1E · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st DOOR FRAME FROM NORTH AT EAST WALL, WEST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 4, 2026 |
| Jul 1, 2026 | C | Apt 1E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS AT THE LOWER SASH WINDOW IN THE 3rd ROOM FROM EAST LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 7, 2026 |
| Jul 1, 2026 | A | Apt 1E · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL, 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 4, 2026 |
| Jul 1, 2026 | B | Apt 1E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE LOWER SASH WINDOW IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 5, 2026 |
| Jul 1, 2026 | B | Apt 1E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE LOWER SASH AT THE 2ND WINDOW FROM SOUTH AT WEST IN THE KITCHEN LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 5, 2026 |
| Dec 30, 2025 | B | Apt 5AB · § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET IN THE 1st BATHROOM FROM NORTH AT WEST LOCATED AT APT 5AB, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 3, 2026 |
| Dec 4, 2025 | C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SIDE WALK SHED BLOCKING FIRE ESCAPE DROP LADDER EGREES AT BUILDING FRONT AT FIRE ESCAPE | Dec 10, 2025 |
| Oct 27, 2025 | B | Apt 1E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Dec 1, 2025 |
| Oct 27, 2025 | A | Apt 1E · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL DOORS AND DOOR TRIMS AND WINDOWFRAMES IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 30, 2026 |
| Oct 27, 2025 | A | Apt 1E · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION ALL RADIATORS AND RISERS IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 30, 2026 |
| Oct 17, 2025 | B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNHINGED IRON GATES AT FENCES , SOUTHEAST AND SOUTHWEST SECTIONS, BUILDING FRONT YARD | Nov 21, 2025 |
| Oct 17, 2025 | B | Apt 4C · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB , SOUTH WALL, IN THE BATHROOM LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 21, 2025 |
| Oct 17, 2025 | B | Apt 4C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CRACKED WOOD DOOR AT ENTRANCE IN THE 1st ROOM FROM EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 21, 2025 |
| Oct 17, 2025 | B | Apt 4C · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT DOOR TO ROOM WITH FIRE ESCAPE IN THE 4th ROOM FROM EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 21, 2025 |
| Oct 17, 2025 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH WINDOW, 2ND FROM WEST AT NORTH WALL , AT PUBLIC HALL STAIRS, 4th STORY | Oct 23, 2025 |
| Aug 25, 2025 | B | Apt 2C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Sep 29, 2025 |
| Aug 25, 2025 | B | Apt 2C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Sep 29, 2025 |
| Jun 24, 2024 | C | Apt 3B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING, SOUTH AND WEST WALLS INSIDE CLOSET (APPROX. 16 SQ. FT.) IN THE FOYER LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 13024712 ISSUED 18-APR-19 HAS BEEN UPGRADED TO CLASS | Jul 20, 2024 |
| Apr 1, 2024 | B | Apt 6E · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AND SOUTH WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST | May 6, 2024 |
| Oct 17, 2023 | A | Apt 1E · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WEST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 20, 2024 |
| Aug 29, 2022 | B | Apt 1E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 3, 2022 |
| Aug 29, 2022 | B | Apt 1E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING 8 SQ FT, SOUTH WALL 7 SQ FT IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 3, 2022 |
| Aug 2, 2022 | C | Apt 3B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 28, 2022 |
| Jul 19, 2021 | B | Apt 1E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 20 SQ FT AT THE CEILING IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 23, 2021 |
| Jan 29, 2019 | B | Apt 1E · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPROXIMATELY 15 SQ. FT AT ALL WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT 1E, 1st STORY, APARTMENT AT WEST | Mar 5, 2019 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 3, 2026 | HPD C | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING KICKSTAND AT DOOR IN THE ENTRANCE LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Aug 26, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Aug 26, 2026 | HPD C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SIDEWALK SCAFFOLD SHED BLOCKING ACCESS TO FIRE ESCAPE WINDOW IN THE 1st ROOM FROM EAST LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Aug 19, 2026 | DOB Safety | Facades: Unsafe 10A FISP report filed | Closed |
| Aug 3, 2026 | ECB | Construction: AT TIME OF INSPECTION, APPROVED DRAWINGS REQUIRED THE SIDEWALK SHED RIGHT-ANGLE CLAMP TO BE SECURED TO THE GROUND WITH A 3/4-INCH HILTI ANCHOR BOLT. REQUIRED ANCHORAGE WAS NOT INSTALLED, COMPROMISING THE APPROV | Open |
| Aug 3, 2026 | ECB | Construction: AT TIME OF INSPECTION, SIDEWALK SHED WAS NOT MAINTAINED. DETERIORATED MUD SILLS HAD SETTLED UNDER THE SHED LOAD CREATING POSSIBLE DISLODGEMENT. SHORING WAS NOT SECURED TO THE MUD SILLS, AND TWO SHORING POSTS WE | Open |
| Jul 10, 2026 | HPD C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE LOWER WINDOW SASH AT 1ST WINDOW FROM EAST AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Jul 10, 2026 | HPD B | 566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF FLIES IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |
| Jul 10, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |
| Jul 10, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |
| Jul 10, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |
| Jul 10, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |
| Jul 10, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |
| Jul 1, 2026 | HPD C | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st WINDOW FRAME FROM EAST AT SOUTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 1E, | Closed |
| Jul 1, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st DOOR FRAME FROM NORTH AT EAST WALL, WEST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Jul 1, 2026 | HPD C | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st WINDOW FRAME FROM EAST AT SOUTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 1E, | Closed |
| Jul 1, 2026 | HPD C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS AT THE LOWER SASH WINDOW IN THE 3rd ROOM FROM EAST LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Jul 1, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE FOYER LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |
| Jul 1, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL, 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Jul 1, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT THE WEST WALL IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |
| Jul 1, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASH BASIN TO THE SOUTH WALL IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |
| Jul 1, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT THE SOUTH WALL IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |
| Jul 1, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE LOWER SASH WINDOW IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Jul 1, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE LOWER SASH AT THE 2ND WINDOW FROM SOUTH AT WEST IN THE KITCHEN LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Jul 1, 2026 | HPD A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 23, 2026, 3:33 AM ET. BBL 3012350050.