Brooklyn · Block 1607 · Lot 68 · 11221

981 Lafayette Avenue

3 floors · 4 apartments · 4,400 sq ft · built 1931 · class C3 · owner of record: 27 Bed Stuy Housing Development Fund Cor Poration

8open violations
$10,000ECB/OATH penalties owed
3HPD class C (immediately hazardous)
58dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 58 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 58 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 74 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 302 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 789 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-17 (Pre-Filing-Pending Payment). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (3) · $10,000 owed
IssuedViolationHearingBalance
Oct 6, 2023Boilers CLASS - 2
AO SMITH BOILER=MISSING BOTH LOW WATER CUT OFFS/FLUE TO CHIMNEY IS INCORRECT/SAFETY VALVE NOT PIPED DOWN/BOILER NOT REGISTERED/OUTSIDE COMBUSTION AIR INLET LOUVER 1/2 CLOGGED/, MAINTAIN BOILER; CORRECT VIOLATIO
#39096676M
Dec 13, 2023
DEFAULT
$3,125
Oct 6, 2023Boilers CLASS - 2
BOILER FLUE BACK PITCHED TO CHIMNEY/SMALLER FLUE NOT ABOVE LARGER FLUE INTO CHIMNEY/CHIMNEY BASE MISSING CLEANOUT;CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION
#39096675K
Jan 8, 2024
IN VIOLATION
$625
Oct 6, 2023Construction CLASS - 2
AO SMITH HOT WATER BOILER WITH 2015 DATE ON RATING PLATE IS INSTALLED WITHOUT A DOB PERMIT, OBTAIN ALL PERMITS; CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION
#39096677Y
Dec 13, 2023
DEFAULT
$6,250
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 3)
Active
HPD (4) · C 3 · B 1 · A 0
IssuedClassViolationCorrect by
Sep 25, 2026CApt 3A · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 4; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APAOct 21, 2026
Jul 6, 2026CApt 1A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTAug 1, 2026
Jul 6, 2026CApt 1A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTAug 1, 2026
Oct 28, 2025BApt 2A · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTDec 2, 2025

Issued in the last 120 days

DateSourceWhatNow
Sep 25, 2026HPD C§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 4; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APAOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 3, 2026, 10:15 AM ET. BBL 3016070068.

Look up another building