Bronx · Block 2690 · Lot 123 · 10459

980 Prospect Avenue

6 floors · 23,674 sq ft · built 1907 · class HR · owner of record: 980 Prospect Owner, Llc

51open violations
$20,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
1163dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1163 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-29 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (43) · $20,000 owed
IssuedViolationHearingBalance
Sep 25, 2026Elevators CLASS - 1
FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLIANT AS PER BC 3001.2 & 27-987. UPON AN FOLLOW UP INSPECTION THE ELEVATOR IS FOUND OUT OF SERVICE FOR MORE THAN 3 WEEKS CREATING A HAZARDOUS CONDITION FOR HUMA
#39205573J
Dec 4, 2026
PENDING
$6,250
Sep 15, 2026Elevators CLASS - 1
FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLIANT AS PER BC3001.2 & 27-987. UPON AN INSPECTION THE ELEVATOR IS FOUND TO BE OUT OF SEVICE THIS IS A RECURRING CONDITION, CREATING A HAZARDOUS CONDITION FOR H
#39204153Z
Nov 20, 2026
PENDING
$3,125
Sep 4, 2026Elevators CLASS - 1
FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON AN INSPECTION THE ELEVATOR IS FOUND TO BE OUT OF SERVICE, THIS A RECURRING CONDITION, CR
#39203159P
Nov 20, 2026
PENDING
$3,125
Aug 18, 2026Elevators CLASS - 1
CLASS 1 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION
#39200923H
Oct 30, 2026
PENDING
$1,250
Jul 21, 2026Elevators CLASS - 1
CLASS 1: EXCESSIVE OIL LEAKAGE FROM THE DRIVING MACHINE HAS CONTAMINATED THE HOISTWAY SELECTOR VANES AND ASSOCIATED EQUIPMENT. DRIVING MACHINE BRAKE LINING IS WORN WITH EXCESSIVE BRAKE DUST ACCUMULATION THROUGH
#39197028R
Oct 2, 2026
IN VIOLATION
$1,250
Apr 17, 2026Elevators CLASS - 1
CLASS 1 CEASE USE: DOOR ZONE RESTRICTOR DEFECTIVE. CODE: ASME A17.1/CSA B44 SEC. 2.12.5. REMEDY: REPAIR/REPLACE AND VERIFY OPERATION. CONTROLLER FUSE BYPASSED. CODE: ASME A17.1/CSA B44 SEC. 8.6.1.2.2. REMEDY: R
#39185094R
Jul 31, 2026
IN VIOLATION
$1,250
Jan 15, 2026Boilers CLASS - 2
I FOUND A H.B. SMITH 28 8 BOILER WERE THE DOMESTIC HOT WATER WAS GOING UP 200 DEGREES ON THE TEMPERATURE GAUGE/WATER IS TO HOT/ CORRECT ALL VIOLATING CONDITIONS/ SUBMIT A CERTIFICATE OF CORRECTION
#39173957P
Aug 28, 2026
ADMIT/IN-VIO
$0
Apr 23, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED PARTITION WALL LEANING INWARD TOWARDS BUILDING AT ROOF LEVEL. ALSO HAS A 3 FOOT CRACK ON TOP OF 6TH FLOOR WINDOW. POTENTIAL HAZARDS., REPAIR AND/R
#39145769J
Oct 17, 2025
IN VIOLATION
$1,250
Apr 23, 2025Construction CLASS - 2
EXIT DOOR NOT SELF-CLOSING. OBSERVED NON SELF CLOSING DOORS THROUGHOUT BUILDING. POTENTIAL FIRE HAZARD., REPAIR/REPLACE DOOR
#39145770R
Jul 18, 2025
IN VIOLATION
$0
Apr 22, 2025Elevators CLASS - 2
CLASS 2 ITEM: COMMUNICATION IN CAR INOPERATIVE. REPLACE WORN COUNTER WEIGHT ROLLERS AS NEEDED. ADJUST CAR DOOR TO PROPERLY OPEN AND CLOSE. ADJUST BOTTOM BASEMENT HOISTWY DOOR. CLEAN OIL FROM MACHINE ROOM FLOOR
#39145656N
Jul 18, 2025
IN VIOLATION
$0
Nov 25, 2024Elevators CLASS - 1
CEASE USE ITEMS: 1)INOPERATIVE ZONE LOCK RESTRICTOR. 2) RIGHT BRAKE PIN WALKING OUT. 125% BRAKE TEST AND SEALING AND TAGGING OF ALL ADJUSTMENTS REQUIRED AT TIME OF REINSPECTION. CLASS 2 ITEMS: PROVIDE DESIGNATE
#39131283M
Jan 31, 2025
IN VIOLATION
$0
Aug 30, 2024Unknown CLASS - 2
AT TIME OF MY INSPECTION I OBSERVED A SIDEWALK SHED AT A OCCUPIED 6 STORY BUILDING. UPON REVIEWING DEPARTMENT OF BUILDING RECORDS I NOTICED THAT PERMIT IS EXPIRED SINCE 2020 AND NO RENEWED PERMIT WAS SUBMITTED.
#39531990Y
Nov 15, 2024
IN VIOLATION
$1,250
Apr 11, 2024Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #907733. REMEDY: SUBMIT ACCEPTABLE REQU
#37027938L
Aug 2, 2024
IN VIOLATION
$1,250
Aug 9, 2022Boilers CLASS - 2
FOUND EXPOSED WIRES, DIRTY GLASS GAUGE, OIL LEAK ON OIL LINE AT BURNER, CORRODED WATER PIPE ABOVE BURNER, CLEAN OUT DOORS ON SIDE OF BOILER NEED TO BE RESEALED, BODY DRAIN MISSING ON SAFETY RELIEF VALVE.
#39067639K
Sep 30, 2022
IN VIOLATION
$0
Aug 9, 2022Unknown CLASS - 2
I OBSERVED UNDER THE SIDEWALK SHED AND ON THE SECOND FLOOR THE POWER SUPPLY FOR THE LIGHTS NOT MECHANICALLY CONNECTED TO THE JUNCTION BOX WITH THE CONDUCTORS EXPOSED AND ENERGIZED. FAILURE TO CONNECT THE RACEWA
#39067694N
Sep 30, 2022
DEFAULT
$0
Aug 9, 2022Unknown CLASS - 1
I OBSERVED THE RACEWAY AND JUNCTION BOXES/LIGHTS FOR THE SIDEWALK SHED NOT CONNECTED OR SECURED PROPERLY AND WITHOUT PROPER GROUNDING AS REQUIRED., COMPLY WITH EC; PROVIDE PROPER GROUNDING AND GFCI PROTECTION.
#39067691H
Sep 30, 2022
DEFAULT
$0
Aug 9, 2022Unknown CLASS - 2
I OBSERVED ON THE FIRST FLOOR IN A REAR STORAGE AREA A BATHROOM AND IN THE BASEMENT NEAR THE BOILER ROOM A CONVENIENCE OUTLET NOT OF THE GFCI TYPE AS REQUIRED WITHIN 6 FEET OF A SINK., INSTALL GFC1 PROTECTION
#39067690X
Sep 30, 2022
DEFAULT
$0
Aug 9, 2022Unknown CLASS - 1
I OBSERVED IN A BASEMENT STORAGE ROOM ALONG THE 164TH STREET SIDE AN ELECTRICAL PANEL MADE INACCESSIBLE BY SHELVING AND SUPPLIES. ALL ELECTRICAL PANELS SHALL HAVE A CLEARANCE FOR ACCESS IN CASE OF NORMAL OR EME
#39067692J
Sep 30, 2022
DEFAULT
$0
Aug 9, 2022Unknown CLASS - 2
I OBSERVED IN THE ELEVATOR MOTOR SWITCH THE IMPROPER FUSING OF THE CONDUCTORS, THE #4 CONDUCTORS HAVE AN AMPACITY LESS THAN THE 100 AMP FUSES THAT ARE INSTALLED AS THE OVERCURRENT PROTECTION OF THE CONDUCTORS.,
#39067693L
Sep 30, 2022
DEFAULT
$0
Jun 14, 2022Unknown CLASS - 2
FAILURE TO OBTAIN A TEMPORARY CONSTRUCTION(SIDEWALK SHED) PERMIT TO REMAIN INSTALL AND USE OF TEMP EQUIPMENT. OBSERVED SWS ERECTED AT EXPOSURE#1&4. DID NOT FIND ACTIVE PERMIT IN BIS AND DOB NOW. PERMIT IN DOB N
#35586211Z
Sep 2, 2022
IN VIOLATION
$0
Apr 29, 2022Construction CLASS - 2
FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES.OBSERVED:AT ROOF LEVEL,PARAPET WALLS,CRACKED ON 2 SIDES,FACADE & INTERIOR SIDE. REMEDY:MAINTAIN EXTERIOR BLDG WALL.
#35654853M
Sep 2, 2022
IN VIOLATION
$0
Apr 29, 2022Construction CLASS - 2
EXIT DOOR NOT SELF CLOSING.OBSERVED:FIRE PROOF SELF-CLOSING DOOR,FROM 6TH FL TO 1ST FL,NEAR ROOMS #40 & CELLAR LEVEL.INTERIOR EXIT DOOR DO NOT ALLOW EASY ESCAPE FROM THE BLDG DOORS DO NOT MEET TECHNICAL & SAFE
#35654854Y
Sep 2, 2022
IN VIOLATION
$0
Apr 29, 2022Construction CLASS - 2
WORK W/OUT A PERMIT.OBSERVED:AT CELLAR LEVEL,FIRE ALARM ROOM,A WALL WAS BUILT IN CMU BLOCKS,CREATING AN ADDITIONAL ROOM.ALSO,METAL STRUCTURE(BEAMS/COLUMNS)WAS INSTALLED TO SUPPORT PART OF THE 1ST FL SLAB.ACTIVI
#35654856H
Sep 2, 2022
IN VIOLATION
$0
Apr 29, 2022Construction CLASS - 2
FAILURE TO MAINTAIN BLDG N CODE COMPLIANT MANNER.OBSERVED:AT ROOF LEVEL,WATERPROOFING MANTLE OR MEMBRANE SHOWS MATERIAL LIFTING FAILURES,CRACKS,OPENINGS IN ENTIRE ROOF AREA.REMEDY:REPAIR &/OR REPLACE.
#35654852K
Sep 2, 2022
IN VIOLATION
$0
Apr 29, 2022Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.OBSERVED:AT CELLAR LEVEL,CEILING/WALLS,OPENING WERE CREATED EXPOSING,REBARS & METALLIC STRUCTURE TO SUPPORT 1ST FL SLAB STRUCTURE.REMEDY:REPAIR &/OR REPLACE.
#35654857J
Sep 2, 2022
IN VIOLATION
$0
Jul 30, 2021Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES.NOTED:OBSEREVED HORIZONTAL AND VERTICAL CRACKS AT ROOF'S PARAPET WALL (ROOF SIDE)AT VARIOUS LOCATIONS.REMEDY:MAINTAIN EXTERIOR BUILDING WALL.
#35582479L
Nov 19, 2021
IN VIOLATION
$0
Nov 21, 2019Construction CLASS - 2
NOTED: OCCUPANCY CONTRARY TO CERTIFICATE OF OCCUPANCY ##8081, ENTIRE FIRST FLOOR OCCUPIED AS OFFICES AND COPY ROOM OVER THE ALLOWABLE 10% FOR ACCESSORY OCCUPANCIES AS PER BC 508, 508.2.1 , DISCONTINUE ILLEGAL O
#39013279M
Mar 11, 2022
IN VIOLATION
$0
Nov 21, 2019Construction CLASS - 2
NOTED: OBSERVED HORIZONTAL AND VERTICAL CRACKS THROUGHOUT PARAPET WALL EXPOSURE #3,#4 AND VARIOUS LOCATIONS THROUGHOUT PARAPET. , MAINTAIN EXTERIOR BUILDING WALL
#39013280J
Mar 11, 2022
IN VIOLATION
$0
Nov 21, 2019Unknown CLASS - 1
I OBSERVED THROUGHOUT THE HALLWAYS ON EVERY FLOOR, LIGHT FIXTURES THAT ARE NOT PROPERLY CONNECTED ( NO MECHANICAL CONNECTION BETWEEN CONDUIT/CABLE AND ELECTRICAL BOX/FIXTURE) EXPOSED ENERGIZED CONDUCTORS @ THE
#39013274N
Oct 23, 2020
IN VIOLATION
$0
May 13, 2019Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. ILLUMINATION FOR EXITS,EXIT DISCHARGES & PUBLIC CORRIDORS PER BC1006.1;27-381. NOTED: EXISTING EMERGENCY LIGHT PACKAGES WERE NOT OPERATIONAL WHEN TESTED AT 6TH
#35293816M
Nov 15, 2019
IN VIOLATION
$0
Feb 9, 2018Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. AS NOTED: EXPOSURE #1 AND 4 CRACKS AT PARAPET LEVEL, SPALLED BRICKS, CRACKED STONES, SPALLED STONES ALL EXPOSURES, EXPOSURE 4 CRACKS IN STORE GROU
#35265118R
Mar 30, 2018
DEFAULT
$0
Oct 3, 2017Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-542.NOTED:AT ALL STORY CORRIDORS,EMERGENCY EXIT LIGHTS NOT WORKIN
#35293673Y
Apr 20, 2018
IN VIOLATION
$0
Oct 3, 2017Unknown CLASS - 2
UNAPPROVED /UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,MATERIALS,APPARATUS DEVICE,APPLIANCE,OR WIRING IN USE.OBSERVED IN BASEMENT AREA STORAGE ROOM AND IMPROPERLY CONNECTED LIGHTS,THE USE OF BAR COPPER CONDUCTORS
#35294225P
Apr 20, 2018
IN VIOLATION
$0
Oct 3, 2017Plumbing CLASS - 2
FAILURE TO MAINTAIN BUIDING IN CODE COMPLIANT MANNER .RE:INSTALLATION MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PC 102.3;27-902. OBSERVED ON 10/3/17 AT ABOVE ADDRESS PVC IPING THROUGH OUT BASEMENT /CELLAR
#35293959J
Apr 20, 2018
IN VIOLATION
$0
Oct 3, 2017Unknown CLASS - 2
ELECTRICAL WORK DOES NOT CONFORM TO SUBMITTED APPROVED DOCUMENTS.OBSERVED NEW 1ED TYPE EMERGENCY LIGHTS THROUGHOUT BUILDING HALLWASYS APPLICATION #152220 COVERS INSTALLATION OF 13 ADDITIONAL EMERGENCY LIGHTS NO
#35294226R
Apr 20, 2018
IN VIOLATION
$0
Jun 12, 2017Construction CLASS - 2
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG DEPT RECORDS.NOTED: ACCORDING TO C OF O#8081 THE 1ST FL SHOULD BE 10 BEDROOMS UTILITY ROOM,STORES,& RESTAURANT. THE ENTIRE 1ST FL IS NOW OFFICES.
#35286809Z
Dec 15, 2017
IN VIOLATION
$0
Mar 17, 2016Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES-NOTED AT TIME OF INSPECTION,PREVIOUS VIOLATED CONDITIONS AT EXPOSURE 1(CRACKED PARAPET)& AT EXPOSURE 4(E 164 ST.)-(I)DANGLING MIS. ANGLE PIECE BY 2/F WINDOW
#35134030M
May 6, 2016
DEFAULT
$0
Jan 27, 2016Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR BLG AS NOTED: AT TIME OF INSPECTION OBSERVED, 1-WEST LOCATION (PROSPECT AV)EXP#1 & 4 (EAST 164 ST) COPING BROKEN/CHIPPED IN VARIOUS AREAS; (II) METAL PC HANGING AT SOUTHWEST CORNER;
#35160466M
Mar 18, 2016
STIPULATION/IN-VIO
$0
Aug 31, 2015Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR BUILDING. EXP1 AND EXP4 ORNAMENTAL FACADEAPPEARS WORN AND HOLLOWED OUT AT EXP1 PARAPET EDGE ON ROOF HAS VISIBLECRACKS.HANGING PC OF METAL AT CORNER OF BUILDING ON FLR 2 MISSING MASO
#35160177X
Oct 16, 2015
STIPULATION/IN-VIO
$0
Sep 12, 2012Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR BLDG EAST ELEVATION, EXP 3 OBSERVE BROKENOFF, DETERIORATING AND MISSING MASONRY FACADE UNITS, DETERIORATING, DISPLACEMENT AND LOOSE IN STEEL PLATE, VERTICAL CRACKS & DISPLACEMENT IN
#34984840Z
Nov 2, 2012
IN VIOLATION
$0
Jan 27, 2010Construction CLASS - 2
FAILURE TO FILE AN ARCHITECT / ENGINEER REPORT CERTIFYING EXIT / DIRECETIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER SOURCE / STORAGE BATTERY EQUIPMENT. REMEDY: FILE ARCHITECT / ENGINEER REPORT.
#36012491X
Aug 6, 2010
DEFAULT
$0
May 21, 2008Boilers Non-Hazardous
B4A32A50A50B. 50A HOLES IN WALLS AND CEILING. 50B DEBRIS IN BOILER ROOM.
#32056293Y
Jul 18, 2008
DEFAULT
$0
Apr 7, 1995Construction Non-Hazardous
FAILURE TO MAINTAIN. DEFECT IS HALLWAY FLOOR SAGGING FROM 2ND FLOOR THRU 6TH FLOOR. REMEDY: MAKE ALL REPAIRS AND REQUEST ENGINE REPORT ON STABILITY.
#34121299X
Jun 23, 1995
STIPULATION/IN-VIO
$0
DOB (3)
IssuedViolationStatus
Jan 22, 2025FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00132
DOB VIOLATION - ACTIVE
Feb 22, 2023NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
#01397
DOB VIOLATION - ACTIVE
Mar 31, 2008EMERGENCY POWER

#NRF01161
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Oct 21, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 14, 2026AEUHAZ FTC-AEU-HAZ
Active
Sep 25, 2026AEUHAZ FTC-AEU-HAZ
Active
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 2)
Active
Jan 22, 2025AEUHAZ FTC-AEU-HAZ
Active
Feb 22, 2023Facades FISPNRF
CYCLE 9B NO REPORT FILED
Active
Mar 31, 2008Emergency Power FTF-EL-ENRF
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 21, 2026DOB SafetyAEUHAZ: Open
Oct 14, 2026DOB SafetyAEUHAZ: Open
Sep 25, 2026ECBElevators: FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLIANT AS PER BC 3001.2 & 27-987. UPON AN FOLLOW UP INSPECTION THE ELEVATOR IS FOUND OUT OF SERVICE FOR MORE THAN 3 WEEKS CREATING A HAZARDOUS CONDITION FOR HUMAOpen
Sep 25, 2026DOB SafetyAEUHAZ: Open
Sep 15, 2026ECBElevators: FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLIANT AS PER BC3001.2 & 27-987. UPON AN INSPECTION THE ELEVATOR IS FOUND TO BE OUT OF SEVICE THIS IS A RECURRING CONDITION, CREATING A HAZARDOUS CONDITION FOR HOpen
Sep 4, 2026ECBElevators: FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON AN INSPECTION THE ELEVATOR IS FOUND TO BE OUT OF SERVICE, THIS A RECURRING CONDITION, CROpen
Aug 18, 2026ECBElevators: CLASS 1 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITIONOpen
Jul 30, 2026DOB SafetyAEUHAZ: Closed
Jul 21, 2026ECBElevators: CLASS 1: EXCESSIVE OIL LEAKAGE FROM THE DRIVING MACHINE HAS CONTAMINATED THE HOISTWAY SELECTOR VANES AND ASSOCIATED EQUIPMENT. DRIVING MACHINE BRAKE LINING IS WORN WITH EXCESSIVE BRAKE DUST ACCUMULATION THROUGHClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)