6 floors · 23,674 sq ft · built 1907 · class HR · owner of record: 980 Prospect Owner, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1163 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-29 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 25, 2026 | Elevators CLASS - 1 FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLIANT AS PER BC 3001.2 & 27-987. UPON AN FOLLOW UP INSPECTION THE ELEVATOR IS FOUND OUT OF SERVICE FOR MORE THAN 3 WEEKS CREATING A HAZARDOUS CONDITION FOR HUMA #39205573J | Dec 4, 2026 PENDING | $6,250 |
| Sep 15, 2026 | Elevators CLASS - 1 FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLIANT AS PER BC3001.2 & 27-987. UPON AN INSPECTION THE ELEVATOR IS FOUND TO BE OUT OF SEVICE THIS IS A RECURRING CONDITION, CREATING A HAZARDOUS CONDITION FOR H #39204153Z | Nov 20, 2026 PENDING | $3,125 |
| Sep 4, 2026 | Elevators CLASS - 1 FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON AN INSPECTION THE ELEVATOR IS FOUND TO BE OUT OF SERVICE, THIS A RECURRING CONDITION, CR #39203159P | Nov 20, 2026 PENDING | $3,125 |
| Aug 18, 2026 | Elevators CLASS - 1 CLASS 1 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION #39200923H | Oct 30, 2026 PENDING | $1,250 |
| Jul 21, 2026 | Elevators CLASS - 1 CLASS 1: EXCESSIVE OIL LEAKAGE FROM THE DRIVING MACHINE HAS CONTAMINATED THE HOISTWAY SELECTOR VANES AND ASSOCIATED EQUIPMENT. DRIVING MACHINE BRAKE LINING IS WORN WITH EXCESSIVE BRAKE DUST ACCUMULATION THROUGH #39197028R | Oct 2, 2026 IN VIOLATION | $1,250 |
| Apr 17, 2026 | Elevators CLASS - 1 CLASS 1 CEASE USE: DOOR ZONE RESTRICTOR DEFECTIVE. CODE: ASME A17.1/CSA B44 SEC. 2.12.5. REMEDY: REPAIR/REPLACE AND VERIFY OPERATION. CONTROLLER FUSE BYPASSED. CODE: ASME A17.1/CSA B44 SEC. 8.6.1.2.2. REMEDY: R #39185094R | Jul 31, 2026 IN VIOLATION | $1,250 |
| Jan 15, 2026 | Boilers CLASS - 2 I FOUND A H.B. SMITH 28 8 BOILER WERE THE DOMESTIC HOT WATER WAS GOING UP 200 DEGREES ON THE TEMPERATURE GAUGE/WATER IS TO HOT/ CORRECT ALL VIOLATING CONDITIONS/ SUBMIT A CERTIFICATE OF CORRECTION #39173957P | Aug 28, 2026 ADMIT/IN-VIO | $0 |
| Apr 23, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED PARTITION WALL LEANING INWARD TOWARDS BUILDING AT ROOF LEVEL. ALSO HAS A 3 FOOT CRACK ON TOP OF 6TH FLOOR WINDOW. POTENTIAL HAZARDS., REPAIR AND/R #39145769J | Oct 17, 2025 IN VIOLATION | $1,250 |
| Apr 23, 2025 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING. OBSERVED NON SELF CLOSING DOORS THROUGHOUT BUILDING. POTENTIAL FIRE HAZARD., REPAIR/REPLACE DOOR #39145770R | Jul 18, 2025 IN VIOLATION | $0 |
| Apr 22, 2025 | Elevators CLASS - 2 CLASS 2 ITEM: COMMUNICATION IN CAR INOPERATIVE. REPLACE WORN COUNTER WEIGHT ROLLERS AS NEEDED. ADJUST CAR DOOR TO PROPERLY OPEN AND CLOSE. ADJUST BOTTOM BASEMENT HOISTWY DOOR. CLEAN OIL FROM MACHINE ROOM FLOOR #39145656N | Jul 18, 2025 IN VIOLATION | $0 |
| Nov 25, 2024 | Elevators CLASS - 1 CEASE USE ITEMS: 1)INOPERATIVE ZONE LOCK RESTRICTOR. 2) RIGHT BRAKE PIN WALKING OUT. 125% BRAKE TEST AND SEALING AND TAGGING OF ALL ADJUSTMENTS REQUIRED AT TIME OF REINSPECTION. CLASS 2 ITEMS: PROVIDE DESIGNATE #39131283M | Jan 31, 2025 IN VIOLATION | $0 |
| Aug 30, 2024 | Unknown CLASS - 2 AT TIME OF MY INSPECTION I OBSERVED A SIDEWALK SHED AT A OCCUPIED 6 STORY BUILDING. UPON REVIEWING DEPARTMENT OF BUILDING RECORDS I NOTICED THAT PERMIT IS EXPIRED SINCE 2020 AND NO RENEWED PERMIT WAS SUBMITTED. #39531990Y | Nov 15, 2024 IN VIOLATION | $1,250 |
| Apr 11, 2024 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #907733. REMEDY: SUBMIT ACCEPTABLE REQU #37027938L | Aug 2, 2024 IN VIOLATION | $1,250 |
| Aug 9, 2022 | Boilers CLASS - 2 FOUND EXPOSED WIRES, DIRTY GLASS GAUGE, OIL LEAK ON OIL LINE AT BURNER, CORRODED WATER PIPE ABOVE BURNER, CLEAN OUT DOORS ON SIDE OF BOILER NEED TO BE RESEALED, BODY DRAIN MISSING ON SAFETY RELIEF VALVE. #39067639K | Sep 30, 2022 IN VIOLATION | $0 |
| Aug 9, 2022 | Unknown CLASS - 2 I OBSERVED UNDER THE SIDEWALK SHED AND ON THE SECOND FLOOR THE POWER SUPPLY FOR THE LIGHTS NOT MECHANICALLY CONNECTED TO THE JUNCTION BOX WITH THE CONDUCTORS EXPOSED AND ENERGIZED. FAILURE TO CONNECT THE RACEWA #39067694N | Sep 30, 2022 DEFAULT | $0 |
| Aug 9, 2022 | Unknown CLASS - 1 I OBSERVED THE RACEWAY AND JUNCTION BOXES/LIGHTS FOR THE SIDEWALK SHED NOT CONNECTED OR SECURED PROPERLY AND WITHOUT PROPER GROUNDING AS REQUIRED., COMPLY WITH EC; PROVIDE PROPER GROUNDING AND GFCI PROTECTION. #39067691H | Sep 30, 2022 DEFAULT | $0 |
| Aug 9, 2022 | Unknown CLASS - 2 I OBSERVED ON THE FIRST FLOOR IN A REAR STORAGE AREA A BATHROOM AND IN THE BASEMENT NEAR THE BOILER ROOM A CONVENIENCE OUTLET NOT OF THE GFCI TYPE AS REQUIRED WITHIN 6 FEET OF A SINK., INSTALL GFC1 PROTECTION #39067690X | Sep 30, 2022 DEFAULT | $0 |
| Aug 9, 2022 | Unknown CLASS - 1 I OBSERVED IN A BASEMENT STORAGE ROOM ALONG THE 164TH STREET SIDE AN ELECTRICAL PANEL MADE INACCESSIBLE BY SHELVING AND SUPPLIES. ALL ELECTRICAL PANELS SHALL HAVE A CLEARANCE FOR ACCESS IN CASE OF NORMAL OR EME #39067692J | Sep 30, 2022 DEFAULT | $0 |
| Aug 9, 2022 | Unknown CLASS - 2 I OBSERVED IN THE ELEVATOR MOTOR SWITCH THE IMPROPER FUSING OF THE CONDUCTORS, THE #4 CONDUCTORS HAVE AN AMPACITY LESS THAN THE 100 AMP FUSES THAT ARE INSTALLED AS THE OVERCURRENT PROTECTION OF THE CONDUCTORS., #39067693L | Sep 30, 2022 DEFAULT | $0 |
| Jun 14, 2022 | Unknown CLASS - 2 FAILURE TO OBTAIN A TEMPORARY CONSTRUCTION(SIDEWALK SHED) PERMIT TO REMAIN INSTALL AND USE OF TEMP EQUIPMENT. OBSERVED SWS ERECTED AT EXPOSURE#1&4. DID NOT FIND ACTIVE PERMIT IN BIS AND DOB NOW. PERMIT IN DOB N #35586211Z | Sep 2, 2022 IN VIOLATION | $0 |
| Apr 29, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES.OBSERVED:AT ROOF LEVEL,PARAPET WALLS,CRACKED ON 2 SIDES,FACADE & INTERIOR SIDE. REMEDY:MAINTAIN EXTERIOR BLDG WALL. #35654853M | Sep 2, 2022 IN VIOLATION | $0 |
| Apr 29, 2022 | Construction CLASS - 2 EXIT DOOR NOT SELF CLOSING.OBSERVED:FIRE PROOF SELF-CLOSING DOOR,FROM 6TH FL TO 1ST FL,NEAR ROOMS #40 & CELLAR LEVEL.INTERIOR EXIT DOOR DO NOT ALLOW EASY ESCAPE FROM THE BLDG DOORS DO NOT MEET TECHNICAL & SAFE #35654854Y | Sep 2, 2022 IN VIOLATION | $0 |
| Apr 29, 2022 | Construction CLASS - 2 WORK W/OUT A PERMIT.OBSERVED:AT CELLAR LEVEL,FIRE ALARM ROOM,A WALL WAS BUILT IN CMU BLOCKS,CREATING AN ADDITIONAL ROOM.ALSO,METAL STRUCTURE(BEAMS/COLUMNS)WAS INSTALLED TO SUPPORT PART OF THE 1ST FL SLAB.ACTIVI #35654856H | Sep 2, 2022 IN VIOLATION | $0 |
| Apr 29, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG N CODE COMPLIANT MANNER.OBSERVED:AT ROOF LEVEL,WATERPROOFING MANTLE OR MEMBRANE SHOWS MATERIAL LIFTING FAILURES,CRACKS,OPENINGS IN ENTIRE ROOF AREA.REMEDY:REPAIR &/OR REPLACE. #35654852K | Sep 2, 2022 IN VIOLATION | $0 |
| Apr 29, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.OBSERVED:AT CELLAR LEVEL,CEILING/WALLS,OPENING WERE CREATED EXPOSING,REBARS & METALLIC STRUCTURE TO SUPPORT 1ST FL SLAB STRUCTURE.REMEDY:REPAIR &/OR REPLACE. #35654857J | Sep 2, 2022 IN VIOLATION | $0 |
| Jul 30, 2021 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES.NOTED:OBSEREVED HORIZONTAL AND VERTICAL CRACKS AT ROOF'S PARAPET WALL (ROOF SIDE)AT VARIOUS LOCATIONS.REMEDY:MAINTAIN EXTERIOR BUILDING WALL. #35582479L | Nov 19, 2021 IN VIOLATION | $0 |
| Nov 21, 2019 | Construction CLASS - 2 NOTED: OCCUPANCY CONTRARY TO CERTIFICATE OF OCCUPANCY ##8081, ENTIRE FIRST FLOOR OCCUPIED AS OFFICES AND COPY ROOM OVER THE ALLOWABLE 10% FOR ACCESSORY OCCUPANCIES AS PER BC 508, 508.2.1 , DISCONTINUE ILLEGAL O #39013279M | Mar 11, 2022 IN VIOLATION | $0 |
| Nov 21, 2019 | Construction CLASS - 2 NOTED: OBSERVED HORIZONTAL AND VERTICAL CRACKS THROUGHOUT PARAPET WALL EXPOSURE #3,#4 AND VARIOUS LOCATIONS THROUGHOUT PARAPET. , MAINTAIN EXTERIOR BUILDING WALL #39013280J | Mar 11, 2022 IN VIOLATION | $0 |
| Nov 21, 2019 | Unknown CLASS - 1 I OBSERVED THROUGHOUT THE HALLWAYS ON EVERY FLOOR, LIGHT FIXTURES THAT ARE NOT PROPERLY CONNECTED ( NO MECHANICAL CONNECTION BETWEEN CONDUIT/CABLE AND ELECTRICAL BOX/FIXTURE) EXPOSED ENERGIZED CONDUCTORS @ THE #39013274N | Oct 23, 2020 IN VIOLATION | $0 |
| May 13, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. ILLUMINATION FOR EXITS,EXIT DISCHARGES & PUBLIC CORRIDORS PER BC1006.1;27-381. NOTED: EXISTING EMERGENCY LIGHT PACKAGES WERE NOT OPERATIONAL WHEN TESTED AT 6TH #35293816M | Nov 15, 2019 IN VIOLATION | $0 |
| Feb 9, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. AS NOTED: EXPOSURE #1 AND 4 CRACKS AT PARAPET LEVEL, SPALLED BRICKS, CRACKED STONES, SPALLED STONES ALL EXPOSURES, EXPOSURE 4 CRACKS IN STORE GROU #35265118R | Mar 30, 2018 DEFAULT | $0 |
| Oct 3, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-542.NOTED:AT ALL STORY CORRIDORS,EMERGENCY EXIT LIGHTS NOT WORKIN #35293673Y | Apr 20, 2018 IN VIOLATION | $0 |
| Oct 3, 2017 | Unknown CLASS - 2 UNAPPROVED /UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,MATERIALS,APPARATUS DEVICE,APPLIANCE,OR WIRING IN USE.OBSERVED IN BASEMENT AREA STORAGE ROOM AND IMPROPERLY CONNECTED LIGHTS,THE USE OF BAR COPPER CONDUCTORS #35294225P | Apr 20, 2018 IN VIOLATION | $0 |
| Oct 3, 2017 | Plumbing CLASS - 2 FAILURE TO MAINTAIN BUIDING IN CODE COMPLIANT MANNER .RE:INSTALLATION MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PC 102.3;27-902. OBSERVED ON 10/3/17 AT ABOVE ADDRESS PVC IPING THROUGH OUT BASEMENT /CELLAR #35293959J | Apr 20, 2018 IN VIOLATION | $0 |
| Oct 3, 2017 | Unknown CLASS - 2 ELECTRICAL WORK DOES NOT CONFORM TO SUBMITTED APPROVED DOCUMENTS.OBSERVED NEW 1ED TYPE EMERGENCY LIGHTS THROUGHOUT BUILDING HALLWASYS APPLICATION #152220 COVERS INSTALLATION OF 13 ADDITIONAL EMERGENCY LIGHTS NO #35294226R | Apr 20, 2018 IN VIOLATION | $0 |
| Jun 12, 2017 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG DEPT RECORDS.NOTED: ACCORDING TO C OF O#8081 THE 1ST FL SHOULD BE 10 BEDROOMS UTILITY ROOM,STORES,& RESTAURANT. THE ENTIRE 1ST FL IS NOW OFFICES. #35286809Z | Dec 15, 2017 IN VIOLATION | $0 |
| Mar 17, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES-NOTED AT TIME OF INSPECTION,PREVIOUS VIOLATED CONDITIONS AT EXPOSURE 1(CRACKED PARAPET)& AT EXPOSURE 4(E 164 ST.)-(I)DANGLING MIS. ANGLE PIECE BY 2/F WINDOW #35134030M | May 6, 2016 DEFAULT | $0 |
| Jan 27, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLG AS NOTED: AT TIME OF INSPECTION OBSERVED, 1-WEST LOCATION (PROSPECT AV)EXP#1 & 4 (EAST 164 ST) COPING BROKEN/CHIPPED IN VARIOUS AREAS; (II) METAL PC HANGING AT SOUTHWEST CORNER; #35160466M | Mar 18, 2016 STIPULATION/IN-VIO | $0 |
| Aug 31, 2015 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING. EXP1 AND EXP4 ORNAMENTAL FACADEAPPEARS WORN AND HOLLOWED OUT AT EXP1 PARAPET EDGE ON ROOF HAS VISIBLECRACKS.HANGING PC OF METAL AT CORNER OF BUILDING ON FLR 2 MISSING MASO #35160177X | Oct 16, 2015 STIPULATION/IN-VIO | $0 |
| Sep 12, 2012 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG EAST ELEVATION, EXP 3 OBSERVE BROKENOFF, DETERIORATING AND MISSING MASONRY FACADE UNITS, DETERIORATING, DISPLACEMENT AND LOOSE IN STEEL PLATE, VERTICAL CRACKS & DISPLACEMENT IN #34984840Z | Nov 2, 2012 IN VIOLATION | $0 |
| Jan 27, 2010 | Construction CLASS - 2 FAILURE TO FILE AN ARCHITECT / ENGINEER REPORT CERTIFYING EXIT / DIRECETIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER SOURCE / STORAGE BATTERY EQUIPMENT. REMEDY: FILE ARCHITECT / ENGINEER REPORT. #36012491X | Aug 6, 2010 DEFAULT | $0 |
| May 21, 2008 | Boilers Non-Hazardous B4A32A50A50B. 50A HOLES IN WALLS AND CEILING. 50B DEBRIS IN BOILER ROOM. #32056293Y | Jul 18, 2008 DEFAULT | $0 |
| Apr 7, 1995 | Construction Non-Hazardous FAILURE TO MAINTAIN. DEFECT IS HALLWAY FLOOR SAGGING FROM 2ND FLOOR THRU 6TH FLOOR. REMEDY: MAKE ALL REPAIRS AND REQUEST ENGINE REPORT ON STABILITY. #34121299X | Jun 23, 1995 STIPULATION/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jan 22, 2025 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00132 | DOB VIOLATION - ACTIVE |
| Feb 22, 2023 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023 #01397 | DOB VIOLATION - ACTIVE |
| Mar 31, 2008 | EMERGENCY POWER #NRF01161 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 21, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 14, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 25, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 2) | Active |
| Jan 22, 2025 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2023 | Facades FISPNRF CYCLE 9B NO REPORT FILED | Active |
| Mar 31, 2008 | Emergency Power FTF-EL-ENRF | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 21, 2026 | DOB Safety | AEUHAZ: | Open |
| Oct 14, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 25, 2026 | ECB | Elevators: FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLIANT AS PER BC 3001.2 & 27-987. UPON AN FOLLOW UP INSPECTION THE ELEVATOR IS FOUND OUT OF SERVICE FOR MORE THAN 3 WEEKS CREATING A HAZARDOUS CONDITION FOR HUMA | Open |
| Sep 25, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 15, 2026 | ECB | Elevators: FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLIANT AS PER BC3001.2 & 27-987. UPON AN INSPECTION THE ELEVATOR IS FOUND TO BE OUT OF SEVICE THIS IS A RECURRING CONDITION, CREATING A HAZARDOUS CONDITION FOR H | Open |
| Sep 4, 2026 | ECB | Elevators: FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON AN INSPECTION THE ELEVATOR IS FOUND TO BE OUT OF SERVICE, THIS A RECURRING CONDITION, CR | Open |
| Aug 18, 2026 | ECB | Elevators: CLASS 1 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Closed |
| Jul 21, 2026 | ECB | Elevators: CLASS 1: EXCESSIVE OIL LEAKAGE FROM THE DRIVING MACHINE HAS CONTAMINATED THE HOISTWAY SELECTOR VANES AND ASSOCIATED EQUIPMENT. DRIVING MACHINE BRAKE LINING IS WORN WITH EXCESSIVE BRAKE DUST ACCUMULATION THROUGH | Closed |