Bronx · Block 2699 · Lot 54 · 10459

979 Intervale Avenue

class G7 · owner of record: 979 Intervale Llc

4open violations
$40,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
—no dated deadlines found

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

We couldn't find building attributes for this lot, so no deadlines are listed.

Open violations

ECB / OATH (10) · $40,000 owed
IssuedViolationHearingBalance
Sep 24, 2026Unknown CLASS - 1
AT TIME OF INSPECTION , UPON REVIEW OF DEPT RECORDS IT REVEALED THEY THERE WERE NO ELECTRONIC FILLING OF AN INCIDENT WITH IN 3 BUSINESS DAYS. INCIDENT OCCURRED 9/14/2026 COMPLAINT# 2450208. FAILURE TO NOTIFY TH
#39559607R
Dec 4, 2026
PENDING
$10,000
Sep 14, 2026Unknown CLASS - 1
AT THE TIME OF INSPECTION OF A 7-STORY NB, RESPONDING TO AN INCIDENT WHERE A WORKER WAS USING A-FRAME LADDER RUNNING CAMERA WIRE ON THE 2ND FLOOR, WORKER FELL FROM 2ND TO 1SR FLOOR, UPON REQUESTING THE SITE SAF
#39559153L
Nov 20, 2026
PENDING
$5,000
Sep 14, 2026Construction CLASS - 2
AT THE TIME OF RESPONDING TO AN INCIDENT, I OBSERVED A WORKER HAD FALLEN FROM AN A-FRAME LADDER AT THE 2ND-FLOOR STAIRCASE LANDING TO THE 1ST-FLOOR GROUND. WORKER WAS USING THE A-FRAME LADDER CONTRARY TO THE MA
#39559154N
Nov 20, 2026
PENDING
$5,000
Sep 14, 2026Unknown CLASS - 1
AT THE TIME OF INSPECTION OF A 7-STORY NEW BUILDING, RESPONDING TO AN INCIDENT WHERE A WORKER WAS USING A-FRAME LADDER RUN CAMERA WIRE IN STAIRWAY AREA, WORKER FELL FROM 2ND FLOOR TO 1ST FLOOR, UPON REQUESTING
#39559152J
Nov 20, 2026
PENDING
$5,000
Aug 5, 2026Unknown CLASS - 2
OBSERVED PROPOSED 7 STORY NB ACTIVE JOB SITE AT DECKING STAGE AT GROUND FLOOR. AT TIME OF INSPECTION I OBSERVED MULTIPLE UNCAPPED REBAR WHICH POSES IMPALEMENT HAZARDS. BC 3301.2PROVIDE/MAINTAIN SAFETY OF EXPOSE
#39557549Z
Jan 22, 2027
$2,500
Aug 5, 2026Site Safety CLASS - 1
OBSERVED PROPOSED 7 STORY NB ACTIVE JOB SITE AT DECKING STAGE AT GROUND FLOOR. AT TIME OF INSPECTION SITE FAILED TO PROVIDE APPROVED PLANS FOR SCOPE OF WORK AT TIME OF INSPECTION.
#39557548R
Jan 22, 2027
$2,500
Jul 20, 2026Unknown CLASS - 1
AT TIME OF INSPECTION I OBSERVED DESIGNATED SITE SAFETY COORDINATOR #3483 WAS ALSO DESIGNATED CONSTRUCTION SUPER ON SEPARATE JOB SITE 666 E 170TH STREET. FAILURE TO COMPLY CREATES CONFLICTING SAFETY CONDITIONS
#39556821Y
Mar 5, 2027
$5,000
Jun 11, 2026Construction CLASS - 2
OBSERVED PLASTIC BARRIERS INSTALLED ON THE ROADWAY EXP1 NOT IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. THE BARRIERS WERE NOT INTERLOCKING AND NOT FILLED WITH WATER OR SAND, AND COULD BE EASILY DISPLACED DU
#39555393M
Feb 12, 2027
$1,250
Apr 21, 2026Unknown CLASS - 2
3301.1.2 FIRE CODE. OBSERVED ACTIVE EXCAVATION/SOE SITE WITH DIESEL COMPRESSOR ONSITE. UPON REQUEST FOR THE FDNY PERMIT FOR THE DIESEL COMPRESSOR ONSITE, NONE WAS PROVIDED AT THE TIME OF INSPECTION AS PER CODE.
#39553263P
Nov 20, 2026
$2,500
Apr 21, 2026Construction CLASS - 2
OBSERVED 7 STORY NB ON EXCAVATION PHASE PREPARING TO DRILL PILES. UPON REQUEST FOR THE VIBRATION AND OPTICAL MONITORING REPORTS FOR THE ADJACENT PROPERTIES @ EXPO 2&4, NONE WERE PROVIDED AT THE TIME OF INSPECTI
#39553262N
Nov 20, 2026
$1,250
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 24, 2026ECBUnknown: AT TIME OF INSPECTION , UPON REVIEW OF DEPT RECORDS IT REVEALED THEY THERE WERE NO ELECTRONIC FILLING OF AN INCIDENT WITH IN 3 BUSINESS DAYS. INCIDENT OCCURRED 9/14/2026 COMPLAINT# 2450208. FAILURE TO NOTIFY THOpen
Sep 14, 2026ECBUnknown: AT THE TIME OF INSPECTION OF A 7-STORY NB, RESPONDING TO AN INCIDENT WHERE A WORKER WAS USING A-FRAME LADDER RUNNING CAMERA WIRE ON THE 2ND FLOOR, WORKER FELL FROM 2ND TO 1SR FLOOR, UPON REQUESTING THE SITE SAFOpen
Sep 14, 2026ECBConstruction: AT THE TIME OF RESPONDING TO AN INCIDENT, I OBSERVED A WORKER HAD FALLEN FROM AN A-FRAME LADDER AT THE 2ND-FLOOR STAIRCASE LANDING TO THE 1ST-FLOOR GROUND. WORKER WAS USING THE A-FRAME LADDER CONTRARY TO THE MAOpen
Sep 14, 2026ECBUnknown: AT THE TIME OF INSPECTION OF A 7-STORY NEW BUILDING, RESPONDING TO AN INCIDENT WHERE A WORKER WAS USING A-FRAME LADDER RUN CAMERA WIRE IN STAIRWAY AREA, WORKER FELL FROM 2ND FLOOR TO 1ST FLOOR, UPON REQUESTINGOpen
Aug 5, 2026ECBUnknown: OBSERVED PROPOSED 7 STORY NB ACTIVE JOB SITE AT DECKING STAGE AT GROUND FLOOR. AT TIME OF INSPECTION I OBSERVED MULTIPLE UNCAPPED REBAR WHICH POSES IMPALEMENT HAZARDS. BC 3301.2PROVIDE/MAINTAIN SAFETY OF EXPOSEClosed
Aug 5, 2026ECBSite Safety: OBSERVED PROPOSED 7 STORY NB ACTIVE JOB SITE AT DECKING STAGE AT GROUND FLOOR. AT TIME OF INSPECTION SITE FAILED TO PROVIDE APPROVED PLANS FOR SCOPE OF WORK AT TIME OF INSPECTION.Closed
Jul 20, 2026ECBUnknown: AT TIME OF INSPECTION I OBSERVED DESIGNATED SITE SAFETY COORDINATOR #3483 WAS ALSO DESIGNATED CONSTRUCTION SUPER ON SEPARATE JOB SITE 666 E 170TH STREET. FAILURE TO COMPLY CREATES CONFLICTING SAFETY CONDITIONSClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 22, 2026, 10:23 PM ET. BBL 2026990054.

Look up another building