5 floors · 15 apartments · 9,145 sq ft · built 1894 · class C4 · owner of record: Ebrahim Realty Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 68 days | Annual |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-11-17 (Accepted). Agency page | Dec 31, 2026 in 68 days | 2 of 2 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 84 days | Annual |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1164 days | Next cycle year 2029 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Dec 31, 2009 | LOW PRESSURE BOILER #01163 | DOB VIOLATION - ACTIVE |
| Oct 26, 2004 | LANDMARK #05-0184 | DOB VIOLATION - ACTIVE |
| Sep 21, 1999 | LANDMARK #00-0166 | DOB VIOLATION - ACTIVE |
| Mar 18, 1993 | LOCAL LAW 62/91 - BOILERS #02144 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 31, 2009 | Boiler LBLVIO | Active |
| Mar 18, 1993 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 19, 2026 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS 4TH STORY BALCONY BUILDING FRONT AT FIRE ESCAPE, 4th STORY | Sep 23, 2026 |
| Jul 20, 2026 | A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION OF THE DUMBWAITERS BEING SEALED SHUT AT THE EAST WALLS ALL STORY AT PUBLIC HALL | Oct 23, 2026 |
| May 3, 2023 | A | Apt 15 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 15, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 6, 2023 |
| Jun 18, 2018 | A | Apt 13 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 13, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 21, 2018 |
| Sep 29, 2017 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING AT PUBLIC HALL, 1st STORY | Jan 2, 2018 |
| Jun 30, 2011 | A | Apt 7 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM SYSTEM IN THE FOYER LOCATED AT APT 7, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 3, 2011 |
| Dec 13, 2005 | B | Apt 9 · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 9, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 22, 2006 |
| Dec 12, 2005 | B | Apt 9 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CAULKING AT SINK IN KITCHEN LOCATED AT APT 9, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 21, 2006 |
| Dec 12, 2005 | B | Apt 9 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER SASH WEST WINDOW AT 1ST ROOM AT NORTH SOUTH. LOCATED AT APT 9, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 21, 2006 |
| Dec 12, 2005 | B | Apt 9 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE GASKET AT REFRIGERATOR IN KITCHEN LOCATED AT APT 9, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 21, 2006 |
| Dec 12, 2005 | B | Apt 9 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER SASH NORTH WINDOW AT 1ST ROOM AT NORTH EAST. LOCATED AT APT 9, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 21, 2006 |
| Date | Source | What | Now |
|---|---|---|---|
| Aug 19, 2026 | HPD B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS 4TH STORY BALCONY BUILDING FRONT AT FIRE ESCAPE, 4th STORY | Open |
| Jul 20, 2026 | HPD A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION OF THE DUMBWAITERS BEING SEALED SHUT AT THE EAST WALLS ALL STORY AT PUBLIC HALL | Open |
| Jul 20, 2026 | HPD A | § 27-2022 ADM CODE POST A SIGN INDICATING HOURS OF COLLECTION AND METHOD OF COLLECTION OF WASTE MATERIAL WHERE DUMBWAITER SERVICE IS NOT PROVIDED. AT PUBLIC HALL, 1st STORY | Closed |
| Jul 20, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE CLOSER ARM IN THE ENTRANCE LOCATED AT APT 15, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Closed |
| Jul 20, 2026 | HPD A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 12:15 PM ET. BBL 1006220026.