Brooklyn · Block 3210 · Lot 1 · 11237

95 Irving Avenue

4 floors · 37,620 sq ft · built 1931 · class W1 · owner of record: Nyc Department Of Education

11open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
66dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 66 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 37,620 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-03 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (8)
IssuedViolationHearingBalance
May 1, 2026Construction CLASS - 2
REISSUE: 35721200M-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. GLASS PANELS OVER CLASS ROOMS ARE CRACKED ON MISSING. ALL FLOORS. REMEDY: COMPLY WITH CODE.
#35732367H
Jun 26, 2026
POP/IN-VIO
$0
May 1, 2026Construction CLASS - 2
REISSUE #35721201Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. FRONT ENTRANCE HAS A SECTION MISSING OF LIME STONE. REMEDY: COMPLY WITH CODE.
#35732366X
Jun 26, 2026
POP/IN-VIO
$0
May 1, 2026Construction CLASS - 2
REISSUE: 3572199Y-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. WALLS HAVE SPALLIN, CRACKLS FROM WATER PENETRATION. STAIRWELL B-D, C-E, G-I, 1, 2, 3, 4 FLOORS. REMEDY: COMPLY WITH CODE.
#35732368J
Jun 26, 2026
POP/IN-VIO
$0
Jul 17, 2025Construction CLASS - 2
REISSUE #35677510M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT AUDITORIUM(RIGHT SIDE) AND HALLOWING, STAIRWELLS(CEILINGS), B-D, C-E, G-I, 1, 2, 3 AND 4 FLOORS, SPALLING, CRACKS AND WATER PE
#35721199Y
Aug 15, 2025
POP/IN-VIO
$0
Jul 17, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT BASEMENT KITCHEN ENTRANCE(1), 1FL. 107(1), 2FL. 202(1), 205(1), 208(1), 3FL.CORRIDOR BY 307(1), 4FL. 401(1), 402(1), 407(1), 409(1), 410(1), 11 BR
#35721200M
Aug 15, 2025
POP/IN-VIO
$0
Jul 17, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNNER. NOTED AT EXPOSURE 4(RIGHT) RUNNING AND STEP CRACKS FLOORS 1, 2, 3. MAIN ENTRANCE DOOR(ABOVE) MISSING SECTION OF LIME STONE. REMEDY: REPAIR AND/OR REPLACE.
#35721201Y
Aug 15, 2025
POP/IN-VIO
$0
Apr 29, 2024Construction CLASS - 2
REISSUE#35671645M FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES.AT TIME OF MY INSPECTION I OBSERVED AT THE EXTERIOR WALL AT THE AUDITORIUM HAS BECOME POROUS ALLOWING THE RAIN WATER INTO THE AUDITORIUM NEE
#35677510M
Jul 24, 2024
POP/IN-VIO
$0
Mar 7, 2023Construction CLASS - 2
FAILURE TO MAINTAIN WALL(S)OR APPURTENANCES.NOTED:EXTERIOR WALL AT AUDITORIUM HAS BECOME POROUS ALLOWING THE YAIN WATER INTO THE AUDITORIUM WALLS.REM:REPAIR/MAINTAIN EXTERIOR WALL.
#35671645M
Jun 7, 2023
POP/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (3)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 9:06 PM ET. BBL 3032100001.