Manhattan · Block 1892 · Lot 13 · 10025

945 West End Avenue

12 floors · 47 apartments · 75,524 sq ft · built 1905 · class D3 · owner of record: 945 Wea Owner Llc

58open violations
$625ECB/OATH penalties owed
13HPD class C (immediately hazardous)
47dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 75,524 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Registered through 2027-09-01
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $1,012,200 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2029
in 830 days
Filing window not open yet
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1143 days
Next cycle year 2029
Energy audit and retro-commissioning (2032) Likely applies
Local Law 87 · Calendar year 2032
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1892). Agency page

Dec 31, 2032
in 2239 days
Next due 2032
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-08 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (6) · $625 owed
IssuedViolationHearingBalance
Jun 7, 2024Boilers CLASS - 2
FAILURE TO FILE REQUIRED ANNUAL BOILER INSPECTION REPORTS FOR LOW-PRESSURE BOILER 006687 IN ACCORDANCE WITH THE RULES OF THE DEPARTMENT.1RCNY 103-01(D)(1)REQUIRES THAT AN ANNUAL INSPECTION REPORT FOR LOW-PRESSU
#37028601K
Sep 19, 2024
IN VIOLATION
$625
May 25, 2024Construction CLASS - 2
SUMMONS ISSUED FOR FAILURE TO MAINTAIN DUE TO WATER DAMAGED SHEETROCK IN THE LIVING ROOM OF APARTMENT 11A., REPAIR AND/OR REPLACE
#39115302Z
Aug 1, 2024
ADMIT/IN-VIO
$0
May 2, 2024Unknown CLASS - 2
I OBSERVED IN APARTMENT NUMBER D12 STAPLED TO THE WALL FLEXIBLE FIXTURE WIRES ARE USED AS PERMANENT WIRING FOR THE DOORBELL. THE WIRES ARE CONNECTED TO AN OUTLET THEN IS RAN TO THE TRANSFORMER FOR THE DOORBELL
#39113333M
Jul 11, 2024
ADMIT/IN-VIO
$0
Apr 15, 2024Construction CLASS - 2
ECB VIO ISSUED FOR GC PERMITS NOT POSTED ANYWHERE ON SITE, POST/PROPERLY POST PERMIT
#39111712N
Jun 20, 2024
ADMIT/IN-VIO
$0
Aug 24, 2023Construction CLASS - 2
AT TIME OF INSPECTION, PREMISES ALTERED UNDER ALT 1 JOB #122174976 OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY - TEMPORARY CERTIFICATE OF OCCUPANCY #1057263-0000003 ISSUED 03-01-2022 EXPIRED 05-30-2022, O
#39093348J
Nov 2, 2023
ADMIT/IN-VIO
$0
Apr 21, 2023Elevators CLASS - 1
CLASS 1 55/H /12 DRUM COUNTERWEIGHTS ROPE WORN RESCHACKLE,52/H/12 HOIST ROPE WORN RSECHACKLE, 2/X/10 OUT SIDE COMM INOPERATIVE REPAIR.
#39084342Y
Jun 29, 2023
ADMIT/IN-VIO
$0
DOB (2)
IssuedViolationStatus
Jun 23, 2024FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023)
#00032
DOB VIOLATION - ACTIVE
Apr 22, 2023FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2022
#10235
DOB VIOLATION - ACTIVE
DOB NOW Safety (4)
IssuedViolationStatus
Sep 25, 2026Benchmarking - LL84 DQ-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Jun 22, 2026Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Jun 23, 2024Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Apr 22, 2023Retro-Commissioning - LL87 FTF-EN-EARCX
Active
HPD (47) · C 13 · B 27 · A 7
IssuedClassViolationCorrect by
Apr 23, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORYMay 7, 2026
Feb 23, 2026A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMAMay 29, 2026
Jun 17, 2025C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT WATER PUMP ROOM AT BASEMENTJul 1, 2025
Apr 17, 2025C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR LEADING TO NORTH YARD AT PUBLIC HALL, 1st STORYMay 1, 2025
Sep 18, 2024BApt 8A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT NORTH WALL . APPROX 6 SQ FT IN THE 3rd ROOM FROM NORTH LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16987402 ISSUED 20-MAY-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE COct 23, 2024
Aug 26, 2024BApt 9A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 9A, 9th STORY, 1st APARTMENT FROM NORTH AT EASTSep 30, 2024
Aug 26, 2024BApt 9A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM LOCATED AT APT 9A, 9th STORY, 1st APARTMENT FROM NORTH AT EASTSep 30, 2024
May 29, 2024A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 1st STORYSep 1, 2024
May 9, 2024CApt 12D · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 12D, 12th STORY, 1st APARTMENT FROM SOUTH AT WESTMay 15, 2024
Mar 8, 2021BApt 12D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT NORTH WALL APPROXIMATELY 18 SQ FEET IN THE 3rd ROOM FROM NORTH LOCATED AT APT 12D, 12th STORY, 1st APARTMENT FROM SOUTH AT WESTApr 12, 2021
Mar 1, 2021BApt 12D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT NORTH WALL APPROX 10 SQ FT IN THE 2nd ROOM FROM NORTH LOCATED AT APT 12D, 12th STORY, 1st APARTMENT FROM WEST AT NORTHApr 5, 2021
Nov 17, 2020A§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER.Feb 20, 2021
Mar 9, 2020A§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORYJun 12, 2020
Feb 3, 2020BApt 9B · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER WINDOW SASH IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 9B, 9th STORY, 1st APARTMENT FROM EAST AT SOUTHMar 9, 2020
May 20, 2019BApt 3A · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRING AT EAST AND SOUTH WALLS IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTJun 24, 2019
May 20, 2019BApt 3A · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LIGHT FIXTURE AT CEILING AT CLOSET IN THE 1st ROOM FROM NORTH LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTJun 24, 2019
Apr 18, 2019AApt 7A · § 27-2065 ADM CODE PROVIDE VENTILATION FOR WATER CLOSET COMPARTMENT AND/OR BATHROOM AND FILE APPLICATION FOR APPROVAL BEFORE DOING WORK ... IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM NORTH AT EASTJul 22, 2019
Apr 16, 2019BApt 7A · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM NORTH AT EASTMay 21, 2019
Feb 6, 2019BApt 7A · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH/BASIN IN THE BATHROOM LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM SOUTH AT WESTMar 13, 2019
Feb 4, 2019BApt 7A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM NORTH AT EASTMar 11, 2019
Feb 4, 2019BApt 7A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM NORTH AT EASTMar 11, 2019
Feb 4, 2019CApt 7A · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 0; WG TO REPAIR = 4; MISSING ONE WAY SCREWS IN AIR CONDITION UNIT AND ALL EXISTINGMar 4, 2019
Jan 7, 2019BApt 12C · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING AND WEST WALL APPROXIMATE 5 SQ. FT. IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 12C, 12th STORY, 2nd APARTMENT FROM EAST AT SOUTHFeb 11, 2019
Jun 11, 2018BApt 9B · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 9B, 9th STORY, 1st APARTMENT FROM EAST AT SOUTHJul 16, 2018
Jun 11, 2018BApt 6A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EASTJul 16, 2018
Jun 11, 2018BApt 9B · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRES AT CEILING AT CLOSET IN THE FOYER LOCATED AT APT 9B, 9th STORY, 1st APARTMENT FROM EAST AT SOUTHJul 16, 2018
Jun 11, 2018BApt 6A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EASTJul 16, 2018
Jun 11, 2018BApt 6A · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EASTJul 16, 2018
Apr 30, 2018BApt 12A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WALLS IN THE KITCHEN LOCATED AT APT 12A, 12th STORY, 2nd APARTMENT FROM EAST AT SOUTHJun 4, 2018
Apr 25, 2018CApt 7F · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 7F, 7th STORY, 1st APAMay 23, 2018
Apr 2, 2018BApt 7A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM NORTH AT EASTMay 7, 2018
Apr 2, 2018BApt 7A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE FOYER LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM NORTH AT EASTMay 7, 2018
Mar 14, 2018BApt 7A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE FOYER LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM NORTH AT EASTApr 18, 2018
Mar 14, 2018BApt 7A · § 27-2005 ADM CODE PROVIDE MECHANICAL VENTILATION IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM NORTH AT EASTApr 18, 2018
Mar 14, 2018BApt 7A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM NORTH AT EASTApr 18, 2018
Mar 14, 2018BApt 7A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM NORTH AT EASTApr 18, 2018
Mar 14, 2018BApt 7A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM NORTH AT EASTApr 18, 2018
Aug 29, 2016BApt 1C · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 1C, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTOct 3, 2016
Jan 25, 2016AApt 7A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ENAMEL GLAZING AT BATHTUB IN THE BATHROOM LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM WEST AT NORTHApr 29, 2016
Jan 25, 2016CApt 7A · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 4; WG TO REPLACE = 1; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 7A, 7th STORY, 1st APAFeb 22, 2016
Nov 16, 2015AApt 9C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN WINDOW RIGHT SIDE JAMB IN THE BATHROOM LOCATED AT APT 9C, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTHFeb 19, 2016
Jul 5, 2013CApt 8A · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM SOUTH AT WEST WALL, 1st DOOR FRAME FROM SOUTH AT WEST WALL, 1st WINDOW FAug 30, 2013
Jul 5, 2013CApt 8A · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM WEST AT NORTH WALL DOOR FRAME, 1st CLOSET FROM EAST AT SOUTH WALL DOORAug 30, 2013
Jul 5, 2013CApt 8A · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM EAST AT SOUTH WALL DOOR, 1st CLOSET FROM EAST AT SOUTH WALL WALL IN THAug 30, 2013
Jul 5, 2013CApt 8A · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, 1st DOOR FROM EAST AT SOUTH WALL, 1st DOOR FROM NORTH AT EAST WALL, NORTH WALAug 30, 2013
Jul 5, 2013CApt 8A · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM SOUTH AT WEST WALL DOOR, 1st CLOSET FROM SOUTH AT WEST WALL DOOR FRAMEAug 30, 2013
Dec 5, 2011CApt 8A · SECTION 27-2056.7 ADM CODE -CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER IN THE ENTIRE APARTMENT LOCATED AT APT 8A, 8th STORYDec 31, 2011

Issued in the last 120 days

DateSourceWhatNow
Sep 25, 2026DOB SafetyBenchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 11:03 AM ET. BBL 1018920013.

Look up another building