Bronx · Block 2755 · Lot 62 · 10474

940 Bryant Avenue

2 floors · 30,450 sq ft · built 1931 · class F4 · owner of record: Vincent Realty Corp.

12open violations
$5,970ECB/OATH penalties owed
0HPD class C (immediately hazardous)
187dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 30,450 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1162 days
Next cycle year 2029

Open violations

ECB / OATH (6) · $5,970 owed
IssuedViolationHearingBalance
Jun 23, 2026Unknown CLASS - 1
I OBSERVED UNSAFE UNSUITABLE CONDITIONS, LIVE ELECTRICAL WIRING AND DEFECTIVE RECEPTACLES EXPOSED ON THE GROUND CAUSING HAZARD CONDITIONS, LOCATED ON THE 1ST FLOOR FOR BIRD SCOOTERS CHARGING AND STORAGE FACILIT
#39193372H
Apr 9, 2027
PENDING
$1,600
Jun 23, 2026Unknown CLASS - 1
I OBSERVED MULTIPLE RECEPTACLE OUTLETS AND GENERAL WIRING, FEEDERS, INSTALLED WITHOUT A PERMIT ON FILE, PERMIT X00899339 DOES NOT COVER THIS WORK . NO ACCESS TO BASEMENT TO VERIFY IF ANY ELECTRICAL WORK WAS INS
#39193376P
Apr 9, 2027
PENDING
$2,500
Apr 21, 2026Construction CLASS - 2
OCCUPANCY CONTRARY TO C OF O#2952, LIST PARKING FOR LESS THEN 5 TRUCKS. OBSERVED 20+ VEHICLES BEING PARKED/STORED, ALSO TWO TRAILERS. SEVERAL VEHICLES HAVE TAXI LICENSE PLATES., DISCONTINUE ILLEGAL OCCUPANCY OR
#39185436H
Jul 31, 2026
STIPULATION/IN-VIO
$620
Apr 21, 2026Construction CLASS - 2
FAILURE TO FILE A CERTIFICATE OF CORRECTION FOR VIOLATION#39092094Y, ISSUED 08/24/23., FILE A CERTIFICATE OF CORRECTION; FILE A CERTIFICATE OF CORRECTION.
#39185432K
Jul 31, 2026
IN VIOLATION
$1,250
Jul 21, 2023Construction CLASS - 2
OCCUPANCY CONTRARY TO C OF O. BUILDING IS STILL BEING USED TO STORE E-BATTERIES, DISCONTINUE ILLEGAL OCCUPANCY OR AMEND C OF O; CONFORM TO C OF O
#39092094Y
Nov 3, 2023
IN VIOLATION
$0
Jul 3, 2023Unknown CLASS - 2
AT THE TIME OF INSPECTION I OBSERVED AN ENTIRE ELECTRICAL BUILD OUT THROUGHOUT THE ENTIRE WAREHOUSE NEW 20 OUTLETS 7 PANEL BOXES WITH BREAKERS E.M.T. RACEWAY WITH WIRES JUNCTION BOXES AND LIGHT FIXTURES NO APPL
#39089620H
Feb 5, 2024
DEFAULT
$0
DOB (3)
IssuedViolationStatus
Apr 29, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2001932
DOB VIOLATION - ACTIVE
Jul 30, 2014CONSTRUCTION
FAIL TO COMPLY WITH COMMISSIONER'S ORDER. THIS BUILDING HAS A WOOD BOWSTRING TRUSS ROOF. THE DOB SERVED YOU A CURABLE COMMISSIONER'S ORDER (NOTICE OF VIOLATION) TO PRODUCE AN ENGINEER'S REPORT ON YOUR BUILDING. NO ENGINEER'S REPORT HAS BEEN RECEIVED. COMPLY WITH THE COMMISSIONER'S ORDER
#FEU20106CM
DOB VIOLATION - ACTIVE
May 1, 2014CONSTRUCTION
940 BRYANT AV:2 STORY OCCUP'D IND./MANU.BLDG/WOOD BOWSTRING TRUSS ROOF WITHIN 60 DAYS OF VIO OWNER TO ENGAGE NYS LIC PE EXPERIENCED W/WOOD TRUSSES,PROBE&EVALUATE STRUCTR'L SOUNDNESS OF BOW TRUSS USING FIELD VERIFICATIONS,CALCULATIONS,PROBES,ETC. EA.TRUSS&BEARINGS EVAL'D. ANY STRUCTURAL DEFICIENCIES
#FEU20205JH
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Oct 14, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 14, 2026AEUHAZ FTC-AEU-HAZ
Active
Apr 29, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 14, 2026DOB SafetyAEUHAZ: Open
Oct 14, 2026DOB SafetyAEUHAZ: Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 25, 2026, 1:14 PM ET. BBL 2027550062.