6 floors · 29 apartments · 21,380 sq ft · built 1916 · class D1 · owner of record: Southside Manhattanview
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 67 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 83 days | Annual |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 798 days | Next cycle year 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-02 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 28, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER FOR VIOLATION #39186938M. OBSERVED A/C UNITS ON FIRE ESCAPES OF EXPOSURE 1 AT THE 6TH,4TH AND 2ND FLOORS AND ON THE 5TH AND 3RD FLOOR OF EXPOSURE 2 HINDERIN #39202232H | Nov 4, 2026 PENDING | $6,250 |
| May 1, 2026 | Construction CLASS - 1 OBSERVED AC UNITS AND FLOWER POTS PARLEY BLOCKING FIRE ESCAPE AT TIME OF INSPECTION., REPAIR AND/REPLACE; REMOVE ALL ITEMS FROM FIRE ESCAPE #39186938M | Jul 8, 2026 DEFAULT | $12,500 |
| Dec 5, 2025 | Construction CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT OR INSTALLATION ON SITE - EXPIRED PERMIT. AT TIME OF INSPECTION OBSERVED SIDEWALK SHED HAS BEEN ERECTED UNDER PERMIT# B01021428, PERMIT HAS EXPIRED ON 07/22/2024. NO RENEWAL ON #39169491K | Feb 11, 2026 DEFAULT | $6,250 |
| Jul 22, 2025 | Construction CLASS - 2 AT THE TIME OF INSPECTION, I OBSERVE THERE IS NO CONSTRUCTION INFORMATION SIGN PROVIDED ON SHED UPPER PARAPET PANEL AS REQUIRED. PROVIDE CONSTRUCTION INFORMATION SIGN ON SHED UPPER PANEL AS REQUIRED. #39542654Z | Oct 1, 2025 DEFAULT | $6,250 |
| Jul 8, 2025 | Unknown CLASS - 2 AT THE TIME OF INSPECTION OCCUPIED 6 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURES#1 AND 2 FOR PEDESTRIAN PROTECTION WORK PERMIT UNDER APPLICATION NUMBER# B01021428-I1 EXPIRED ON 07/22/2024 UPO #39542126P | Sep 24, 2025 DEFAULT | $6,250 |
| Sep 6, 2024 | Cranes and Derricks CLASS - 2 AT THE TIME OF INSPECTION 6-STORY OCCUPIED MULTI-FAMILY BUILDING OBSERVED SUSPENDED SCAFFOLD IN USE AT EXPOSURE 2. UPON REVIEWING RECORDS, IT REVEALED THAT THE DEPARTMENT WAS NOT NOTIFIED PRIOR TO INSTALLATION #39532161L | Jun 29, 2026 DEFAULT | $10,000 |
| Sep 6, 2024 | Construction CLASS - 1 AT TIME OF INSPECTION 6-STORY OCCUPIED MULTI-FAMILY BUILDING OBSERVED FACADE WORK IN PROGRESS, 4 CONSTRUCTION WORKERS SUSPENDED SCAFFOLD IN USE, 150 SQFT OF PARAPET IS REMOVED, MATERIALS HOISTING. UPON REVIEWIN #39532156R | Jun 29, 2026 DEFAULT | $12,500 |
| Sep 6, 2024 | Unknown CLASS - 2 AT THE TIME OF INSPECTION 6-STORY OCCUPIED MULTI-FAMILY BUILDING OBSERVED SIDEWALK SHED INSTALLED AT EXPOSURE 1 AND 2. WORK PERMIT B01021428-I1-SH EXPIRED 07/22/2024, THAT CREATES MAJOR HAZARD FOR PUBLIC AND PR #39532162N | Jun 29, 2026 DEFAULT | $6,250 |
| Sep 5, 2024 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE PERMITTED SIDEWALK SHED.INSTALLED AT 94 HAVEMEYER STREET I OBSERVED SIDEWALK SHED WITH INADEQUATE LIGHTING AND MISSING LIGHTING AND INADEQUATE PARAPET AT EXPOSURE D FRON #35668106X | Jun 29, 2026 DEFAULT | $10,000 |
| Issued | Violation | Status |
|---|---|---|
| Sep 5, 2024 | CONSTRUCTION STRUCTURE RENDERED NON COMPLIANT NOTED : PERMITTED SIDEWALK SHED INST ALLED AT 94 HAVEMEYER STREET WITH PERMIT # ( B01021428) HAS BEEN IMPAC TED BY A MOTORCYCLE DAMGING THE CROSS BRACINGS AT EXPOSURE #1 #CER01CW | DOB VIOLATION - ACTIVE |
| Apr 6, 2018 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT #07525 | DOB VIOLATION - ACTIVE |
| Jan 26, 2018 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST #12786 | DOB VIOLATION - ACTIVE |
| Jan 3, 2017 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST #12650 | DOB VIOLATION - ACTIVE |
| Nov 14, 2016 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST #13742 | DOB VIOLATION - ACTIVE |
| Feb 27, 2001 | LOCAL LAW 62/91 - BOILERS #17723 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #19316 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Apr 6, 2018 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT | Active |
| Jan 26, 2018 | Elevators ACC1 | Active |
| Jan 3, 2017 | Elevators ACC1 | Active |
| Nov 14, 2016 | Elevators ACC1 | Active |
| Feb 27, 2001 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 4, 2024 | B | Apt 1D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE REGROUT AT BATHTUB IN THE BATHROOM LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 9, 2024 |
| Sep 4, 2024 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS YARD | Sep 30, 2024 |
| Mar 2, 2020 | C | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING ASSEMBELY AT BUILDING ENTERANCE DOOR AT PUBLIC HALL, 1st STORY | Mar 10, 2020 |
| Jul 26, 2010 | B | Apt 3D · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 30, 2010 |
| Jul 26, 2010 | B | Apt 3D · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 30, 2010 |
| Jun 24, 2008 | A | Apt 6 · D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR KITCHEN 2 STY NORTHWEST APT 6. , SECTION '' '' | Sep 27, 2008 |
| Jun 24, 2008 | A | Apt 6 · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CLG CENTER SOUTH ROOM 2 STY NORTHWEST APT 6. , SECTION '' '' | Sep 27, 2008 |
| Jun 24, 2008 | C | Apt 1 · D26-17.07 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES BATHROOM & KITCHEN 1 STY NORTHWEST APT 1. , SECTION '' '' | Jun 30, 2008 |
| Jun 24, 2008 | C | D26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUBLIC HALL & ON BOILER ROOM DOOR. | Jun 30, 2008 |
| Jun 24, 2008 | C | Apt 1 · D26-32.01 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES KITCHEN GAS RANGE 1ST STY SOUTH APT 1. , SECTION '' '' | Jun 30, 2008 |
| Jun 24, 2008 | A | D26-34.01 ADM CODE THOROUGHLY WHITEWASH OR PAINT WITH A LIGHT COLOR THE SURFACES WALLS & CEILINGS BOILER ROOM CELLAR. | Sep 27, 2008 |
| Jun 24, 2008 | A | Apt 3 · D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE DOOR SADDLE ENTRANCE TO 1 STY SOUTHWEST APT 3. LOCATED AT APT 3 | Sep 27, 2008 |
| Jun 24, 2008 | B | Apt 6 · D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BOTTOM RAIL BOTTOM SASH SOUTHWEST ROOM 2 STY NORTHWEST APT 6. , SECTION '' '' | Jul 29, 2008 |
| Jun 24, 2008 | B | Apt 6 · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED WIRING CLG LIGHT NORTHWEST ROOM 2 STY NORTHWEST APT 6. , SECTION '' '' | Jul 29, 2008 |
| Jul 28, 2006 | A | Apt 5E · SECTION 27-2005 ADM CODE REFIT UNHINGED CLOSET DOOR SOUTH ROOM 5 STY NORTH WEST APT 5E. , SECTION '' '' | Nov 24, 2006 |
| Jul 28, 2006 | A | SECTION 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY | Nov 24, 2006 |
| Jul 28, 2006 | A | Apt 5E · SECTION 27-2005 ADM CODE REFIT WINDOW THROUGHOUT 5 STY NORTH WEST APT 5E. , SECTION '' '' | Nov 24, 2006 |
| Jul 28, 2006 | A | Apt 5E · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING AND WOOD WORK THROUGHOUT 5 STY NORTH WEST APT 5E. , SECTION '' '' | Nov 24, 2006 |
| May 9, 2005 | B | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRIC SWITCH COVER AT SOUTH WALL AT PUBLIC HALL, 1st STORY | Jun 18, 2005 |
| Feb 10, 2004 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 200 Watts required | Mar 21, 2004 |
| Jul 30, 2001 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK ENTRANCE DOOR AT LOBBY | Sep 8, 2001 |
| Apr 14, 1998 | B | Apt 5E · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE AT 5 STY NORTH WEST APT 5E SMITH. , SECTION '' '' | Jun 1, 1998 |
| Apr 14, 1998 | B | Apt 5E · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOOSE AND HANGING OVEN DOOR GAS RANGE KITCHEN 5 STY NORTH WEST APT 5E. , SECTION '' '' | Jun 1, 1998 |
| Aug 7, 1990 | B | SECTION 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER PROTRUDING OUT SOUTH WINDOW FRONT. | Sep 24, 1990 |
| Aug 7, 1990 | B | SECTION 27-2050 ADM CODE PROVIDE 3 EXTRA SPRINKLER HEADS AND SUITABLE WRENCH FOR EMERGENCY PURPOSES AT O.S.Y. VALVE OF SPRINKLER IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT CELLAR SOUTH | Sep 24, 1990 |
| Aug 7, 1990 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE CEILING CELLAR & BOILER ROOM THRU OUT | Sep 24, 1990 |
| Aug 7, 1990 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES 4 STY PUBLIC HALL REAR | Sep 24, 1990 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Aug 28, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER FOR VIOLATION #39186938M. OBSERVED A/C UNITS ON FIRE ESCAPES OF EXPOSURE 1 AT THE 6TH,4TH AND 2ND FLOORS AND ON THE 5TH AND 3RD FLOOR OF EXPOSURE 2 HINDERIN | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 4:33 AM ET. BBL 3023680029.