4 floors · 3 apartments · 6,607 sq ft · built 1901 · class C0 · owner of record: 939 Bedford Av Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 51 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 51 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 67 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 782 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 5, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOSURE 1 NOT CONSTRUCTED OR MAINTAINED ACCORDING TO CODE. FENCE NOT MAINTAINED IN SOUND CONDITION. PROTRUDING OBJECTS (NAILS, SCREWS, DAMAGED WOOD). FENCE NOT F #39561569H | Jan 13, 2027 PENDING | $1,000 |
| Nov 5, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOSURE 1 WITH AN INADEQUATE SIDEWALK SHED PROJECT INFO PANEL INSTALLED. PROJECT INFO PANEL WAS NOT LEGIBLE AND SECURELY ATTACHED TO THE PARAPET CONTRARY #39561573K | Jan 13, 2027 PENDING | $1,250 |
| Nov 5, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOSURE 1 CONTRARY TO CODE. MULTIPLE VERTICAL MEMBERS PLACED WITHIN 18 INCHES FROM THE FACE OF THE CURB LINE CONTRARY TO CODE 3307.6.4.4 VERTICAL MEMBER #39561576X | Jan 13, 2027 PENDING | $2,400 |
| Aug 17, 2026 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION I OBSERVED COLD FORM STEEL INSTALLED ON EVERY FLOOR-UPON ASKING FOR COLD FORM STEEL MANUFACTURERS SPECIFICATIONS FOR INSTALLATION-NONE WERE PROVIDED-STOP ALL COLD FORM STEEL WORK/PR #39558054L | Dec 9, 2026 PENDING | $1,250 |
| Aug 17, 2026 | Unknown CLASS - 2 BC 3314.3.4-LOAD IMPOSED LETTER-AT THE TIME OF MY INSPECTION I OBSERVED PUMP JACK SCAFFOLD(SUPPORTED SCAFFOLD RESTING ON ROOF) INSTALLED AT ADJ PROPERTY ROOF EXP#4-UPON ASKING FOR LOAD IMPOSED LETTER-NONE WAS P #39558057R | Dec 9, 2026 | $2,500 |
| Aug 17, 2026 | Construction CLASS - 1 I OBSERVED PUMP JACKS SCAFFOLD INSTALLED CONTRARY TO MANUFACTURERS SPECIFICATIONS-POLES INSTALLED APPROX. 30-35 FEET HIGH -AS PER MAN. SPECS IF POLES LONGER THAN 24' BRACE TO WALL SHALL BE INSTALLED EVERY 16',M #39558056P | Dec 9, 2026 | $2,500 |
| Aug 17, 2026 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION I OBSERVED COLD FORM STEEL INSTALLED CONTRARY TO PLANS-AS PER APPROVED PLANS STRAP SHALL BE INSTALLED ON BOTTOM OF ALL BRACING-NO STRAPS INSTALLED AT ANY BLOCKS LOCATION-ON ANY FLOO #39558053J | Dec 9, 2026 PENDING | $1,250 |
| Aug 22, 2025 | Construction CLASS - 2 OBSERVED SITE CLOSED NO ONGOING CONSTRUCTION ACTIVITY .UPON INSPECTION NOTED FENCE ERECTED ON EXPOSURE 1 MISSING PANELS VIEW CONTRARY TO BC3307.7.3 #39544041P | Nov 5, 2025 DEFAULT | $2,500 |
| May 8, 2025 | Construction CLASS - 1 SWO ISSUED 2/6/2025 FOR WORK BEING DONE WITHOUT A PERMIT. STOP ALL WORK ENTIRE SITE. UPON REVIEWING PREVIOUS PICTURES AND TODAYS PICTURES. I OBSERVED THE 2ND FLOOR OF THE BUILDING WAS FRAMED AND PLYWOOD WAS INS #39540027K | Feb 2, 2026 IN VIOLATION | $10,000 |
| Feb 6, 2025 | Construction CLASS - 1 ACTIVE SITE OBSERVED WORKER WORKING USING EXTENSION LADDER PERFORMING HIS DUTIES. UPON REVIEW TO THE DOB RECORDS INDICATED NO ACTIVE PERMIT ON FILE. STOP ALL WORK ON ENTIRE SITE. #39536717X | Dec 1, 2025 IN VIOLATION | $2,500 |
| Feb 6, 2025 | Construction CLASS - 2 AT TIME OF MY INSPECTION OBSERVED CONSTRUCTION SITE WITH NO CONSTRUCTION FENCE EXP# 1 3 TO PROTECT THE PUBLIC FROM HAZARDOUS CONDITION THERE UNPROTECTED HOLES , STEEL PROTRUDING OF THE SIDE. STOP ALL WORK ENT #39536728L | Dec 1, 2025 IN VIOLATION | $1,000 |
| Feb 6, 2025 | Construction CLASS - 2 ACTIVE SITE OBSERVED WORKER WORKING USING EXTENSION LADDER TO PERFORM HIS DUTIES UPON KNOCKING AND REQUESTING ACCESS WORKER DENIED ME ACCESS TO AN ACTIVE CONSTRUCTION SITE . FULL STOP WORK ORDER ISSUED FOR DENI #39536714K | Dec 1, 2025 IN VIOLATION | $2,500 |
| Aug 26, 2019 | Construction CLASS - 1 HOUSEKEEPING. AT TIME OF INSPECTION OF A BLDG UNDER RENOVATION I OBSERVED LARGE AMOUNT OF CONSTRUCTION DEBRIS CLUTTERED AT FRONT YARD EXPO#1CREATING A TRIP HAZARD NO WORK IN PROGRESS. REMEDY:PROVIDE AND MAINTAI #35438836Y | Aug 24, 2020 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 4, 2019 | CONSTRUCTION .DUE TO FIRE #CNE04LC | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 6, 2009 | B | Apt 1 · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY | Sep 10, 2009 |
| Aug 6, 2009 | B | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING CERAMIC FLOOR TILES IN THE VESTIBULE AT PUBLIC HALL, BASEMENT | Sep 10, 2009 |
| Aug 6, 2009 | B | SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE HANDRAIL AT PUBLIC HALL STAIRS, BASEMENT | Sep 10, 2009 |
| Aug 6, 2009 | A | Apt 1 · SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE ESCUTCHEON PLATEON HEAT RISERAT CEILING IN THE 1st BEDROOM FROM WEST LOCATED AT APT 1, 1st STORY | Nov 9, 2009 |
| Aug 6, 2009 | A | SECTION 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE REAR YARD | Nov 9, 2009 |
| Aug 6, 2009 | B | Apt 2 · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES THRUOUT IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY | Sep 10, 2009 |
| Date | Source | What | Now |
|---|---|---|---|
| Nov 5, 2026 | ECB | Construction: UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOSURE 1 NOT CONSTRUCTED OR MAINTAINED ACCORDING TO CODE. FENCE NOT MAINTAINED IN SOUND CONDITION. PROTRUDING OBJECTS (NAILS, SCREWS, DAMAGED WOOD). FENCE NOT F | Open |
| Nov 5, 2026 | ECB | Construction: UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOSURE 1 WITH AN INADEQUATE SIDEWALK SHED PROJECT INFO PANEL INSTALLED. PROJECT INFO PANEL WAS NOT LEGIBLE AND SECURELY ATTACHED TO THE PARAPET CONTRARY | Open |
| Nov 5, 2026 | ECB | Construction: UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOSURE 1 CONTRARY TO CODE. MULTIPLE VERTICAL MEMBERS PLACED WITHIN 18 INCHES FROM THE FACE OF THE CURB LINE CONTRARY TO CODE 3307.6.4.4 VERTICAL MEMBER | Open |
| Aug 17, 2026 | ECB | Construction: AT THE TIME OF MY INSPECTION I OBSERVED COLD FORM STEEL INSTALLED ON EVERY FLOOR-UPON ASKING FOR COLD FORM STEEL MANUFACTURERS SPECIFICATIONS FOR INSTALLATION-NONE WERE PROVIDED-STOP ALL COLD FORM STEEL WORK/PR | Open |
| Aug 17, 2026 | ECB | Construction: AT THE TIME OF MY INSPECTION I OBSERVED PUMP JACKS SCAFFOLDS(SUPPORTED SCAFFOLD) INSTALLED AT EXP#4-IN USE,OBSERVED TRAMPOLINE LOCATED DIRECTLY UNDER PUMP JACKS/WORK AREA-LOCATION/USE OF PUMP JACKS NOT ON SSP,N | Closed |
| Aug 17, 2026 | ECB | Unknown: BC 3314.3.4-LOAD IMPOSED LETTER-AT THE TIME OF MY INSPECTION I OBSERVED PUMP JACK SCAFFOLD(SUPPORTED SCAFFOLD RESTING ON ROOF) INSTALLED AT ADJ PROPERTY ROOF EXP#4-UPON ASKING FOR LOAD IMPOSED LETTER-NONE WAS P | Closed |
| Aug 17, 2026 | ECB | Construction: I OBSERVED PUMP JACKS SCAFFOLD INSTALLED CONTRARY TO MANUFACTURERS SPECIFICATIONS-POLES INSTALLED APPROX. 30-35 FEET HIGH -AS PER MAN. SPECS IF POLES LONGER THAN 24' BRACE TO WALL SHALL BE INSTALLED EVERY 16',M | Closed |
| Aug 17, 2026 | ECB | Construction: AT THE TIME OF MY INSPECTION I OBSERVED COLD FORM STEEL INSTALLED CONTRARY TO PLANS-AS PER APPROVED PLANS STRAP SHALL BE INSTALLED ON BOTTOM OF ALL BRACING-NO STRAPS INSTALLED AT ANY BLOCKS LOCATION-ON ANY FLOO | Open |