3 floors · 3 apartments · 2,700 sq ft · built 1910 · class C0 · owner of record: Az 936 Pacific St Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2022-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 64 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 64 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 80 days | Annual |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 20, 2025 | Unknown CLASS - 2 BC 3314.4.8 MAINTENANCE. AT TIME OF INSPECTION OBSERVED: ACTIVE JOB SITE WOOD FRAMEWORK IN PROGRESS USING UNSAFE SUPPORTED SCAFFOLD CONTRARY TO CODE. NO SCREW JACKS, NO GUARDRAILS, NO FULLY PLANKED, CRATING UNS #39537173L | Nov 9, 2026 | $2,500 |
| Feb 20, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED: ACTIVE JOB SITE, BIG PILE OF WOOD DEBRIS AT REAR YARD, CREATING FIRE HAZARDOUS CONDITIONS FOR ADJOINING OCCUPIED PROPERTIES.PROVIDE ADEQUATE HOUSEKEEPING. #39537174N | Nov 9, 2026 | $1,250 |
| Feb 20, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED: ACTIVE JOB SITE WOOD FRAMEWORK IN PROGRESS AT REAR 2DN FLOOR LEVEL, AT TO OPEN LEADING EDGE NO MEANS ON SAFETY MEASURES, CREATING FALLINGHAZZARDOUS CONDITION. AT OPEN PERIMETER A #39537172J | Nov 9, 2026 | $5,000 |
| Feb 20, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED: ACTIVE JOB SITE 3 WORKERS DOING WOOD FRAMEWORK AT REAR, UPON ASKING FOR ACCESS NONE WAS PROVIDED, CREATING UNSAFE CONDITIONS FOR SUPERVISION AND SAFETY MONITORING.. STOP ALL WORK #39537170X | Nov 9, 2026 | $2,500 |
| Feb 20, 2025 | Unknown CLASS - 1 BC 3309.1 AT TIME OF INSPECTION OBSERVED: ACTIVE JOB SITE, CONSTRUCTION REACHED 43 FEET HEIGHT, NO OVERHEAD PROTECTION FOR ADJOINING PROPERTIES AT EXPOSURE# 2/4 FRONT AND REAR CREATING POTENTIAL SAFETY HAZARDOU #39537171H | Nov 9, 2026 | $5,000 |
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 16, 2026 | B | § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS MINIMUM REQUIRED, LIGHT FIXTURE PRESENT | Oct 21, 2026 |
| Sep 16, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE FLOOR AT PUBLIC HALL, 1st STORY | Oct 21, 2026 |
| Sep 16, 2026 | B | Apt 2 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL COVERING AT ALL TREADS AT PUBLIC HALL STAIRS, 1st STORY | Oct 21, 2026 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 16, 2026 | HPD B | § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS MINIMUM REQUIRED, LIGHT FIXTURE PRESENT | Open |
| Sep 16, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE FLOOR AT PUBLIC HALL, 1st STORY | Open |
| Sep 16, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL COVERING AT ALL TREADS AT PUBLIC HALL STAIRS, 1st STORY | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 28, 2026, 4:10 AM ET. BBL 3011320028.