3 floors · 6 apartments · 4,125 sq ft · built 1930 · class C2 · owner of record: Sonaal Industries Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 49 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 49 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-01 (Accepted). Agency page | Dec 31, 2026 in 49 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 65 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 293 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 780 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 18, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDERS TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT OF BUILDINGS FOR VIO # 39187922M, FILE A CERTIFICATE OF CORRECTION #39200873Z | Nov 27, 2026 PENDING | $1,250 |
| Aug 18, 2026 | Construction CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO OBTAIN A PERMIT FOR VIO# 39187924X. NO PERMIT ON FILE FOR ERECTION OF FULL HEIGHT PARTITIONS TO CREATE 2 SEPARATE SPACES IN 3RD FL APARTMENT, CO #39200874K | Oct 28, 2026 DEFAULT | $2,530 |
| May 8, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1 (2008 CODE); 27- 366; BC 1021.1 (2014 CODE); BC 1006.3 (2022 CODE). AT TIME OF INS #39187922M | Jul 15, 2026 DEFAULT | $12,500 |
| May 8, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE. AT TIME OF INSPECTION OBSERVED IMPROPER LOCKING DEVICES AT APT.3R OBSERVED DEADBOLTS USED TO LOCK ROOMS AND SLIDE B #39187923Y | Jul 15, 2026 DEFAULT | $6,250 |
| May 8, 2026 | Construction CLASS - 1 WORK WITHOUT A PERMIT. AT TIME OF INSPECTION OBSERVED CONSTRUCTION WORK WITHOUT PERMIT FULL HEIGHT PORTIONS SUBDIVIDING THE 3RD FLOOR APT 3R RAILROAD APARTMENT HAS SEALED OFF THE MIDDLE CREATING 2 SEPARATE SPAC #39187924X | Jul 15, 2026 DEFAULT | $12,500 |
| Apr 14, 2021 | Boilers CLASS - 2 RATING TAG MISSING FROM BOILER, FLUE PIPE NOT SEALED TO CHIMNEY HARDFORD LOOP ROTTED CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION #39039290Z | Aug 18, 2021 DEFAULT | $3,125 |
| Issued | Violation | Status |
|---|---|---|
| Aug 18, 2026 | IMMEDIATE EMERGENCY INSTALL APPROX 35 LINEAR FT OF SIDEWALK SHED ALONG THE ENTIRE FRONT OF 1 & EXTEND PAST THE BUILDING BY 5 FT ON BOTH SIDES. THE SIDEWALK SHED SHALL BE INSTALLED TIGHT BACK TO THE BUILDING AND EXTEND OVER THE SIDE WALK. EXPOSURE 1: APPROXIMATELY 35 LINEAR FT OF SIDEWALK SHED #20524 | DOB VIOLATION - ACTIVE |
| Aug 18, 2026 | UNSAFE BUILDINGS #3914/2026 | DOB VIOLATION - ACTIVE |
| May 8, 2026 | CONSTRUCTION FTM-DUE TO 4 ALARM FIRE OCCURRED ON 5/3/26 @ADJ PROPERTY.EXP2(WEST WALL)&PARTY WALL BY EXP4(EAST WALL)SUFFERED DAMAGE AS FOLLOWS:INDEP WALL EXP2 WAS EXPOSED&IN DISRPAIR.CHIMNEY @EXP2 PART COLLAPSE.OWNER TO ENGAGE A NYSPE & ENDORSED CONT'R TO EVAL WHOLE BLDG,OBTAIN PERMIT FOR REPAIR OF BLDG NO LATER #FEU30101FF | DOB VIOLATION - ACTIVE |
| May 4, 1998 | LOCAL LAW 62/91 - BOILERS #24829 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
| May 4, 1998 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 13, 2026 | I | § 27-2089 ADM CODE THE PREMISES HAVE BEEN VACATED BY AN ORDER OF THIS DEPARTMENT AND CANNOT BE REOCCUPIED EXCEPT FOR CARETAKER, UNTIL (1) AN APPLICATION AND PLAN FOR THE WORK REQUIRED BY THIS ARTICLE HAVE BEEN FILED WITH AND APPROVED BY THE DEPARTMENT OF BUILDINGS, WHERE REQUIRED, (2) SUCH WORK HAS | — |
| May 13, 2026 | C | Apt 3L · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | May 19, 2026 |
| May 13, 2026 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICKS AND MORTAR JOINTS AT THE WEST AND NORTH EXTERIOR WALLS | May 19, 2026 |
| May 13, 2026 | C | Apt 2L · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | May 19, 2026 |
| May 13, 2026 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DECKING AND ASPHALT MATERIAL AT ROOF | May 19, 2026 |
| May 13, 2026 | C | Apt 3R · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | May 19, 2026 |
| May 13, 2026 | C | Apt 1L · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 19, 2026 |
| May 13, 2026 | C | Apt 1R · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | May 19, 2026 |
| May 13, 2026 | C | Apt 2R · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 19, 2026 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE ESCAPE WINDOW BLOCKED BY AIR CONDITIONING IN THE KITCHEN LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS AND CEILINGS IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAKE OPERABLE UPPER AND LOWER SASHES ALL WINDOWS 3 STY SOUTH APT 3R , SECTION '' '' | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES FLOOR BATHROOM 3 STY SOUTH APT 3R , SECTION '' '' | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES THROUGHOUT 3 STY SOUTH APT 3R , SECTION '' '' | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 3 STY SOUTH APT 3R , SECTION '' '' | Nov 5, 2025 |
| Oct 1, 2025 | A | Apt 3R · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING WEST ROOM 3 STY SOUTH APT 3R , SECTION '' '' | Jan 4, 2026 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOORS FRONT AND REAR ENTRANCE 3 STY SOUTH APT 3R , SECTION '' '' | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW SASHES UPPER AND LOWER AT NORTH WALL IN THE KITCHEN LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW SILL AT NORTH WALL IN THE KITCHEN LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 5, 2025 |
| Oct 1, 2025 | A | Apt 3R · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE HEAT RISER IN THE BATHROOM LOCATED AT APT 3R, 3rd STORY, APARTMENT AT EAST | Jan 4, 2026 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL OUTLETS AT NORTH WALL IN THE KITCHEN LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE KITCHEN LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3R, 3rd STORY, APARTMENT AT EAST | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST AND SOUTH WALLS IN THE 1st ROOM FROM NORTH LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS IN THE 1st ROOM FROM NORTH LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 1st ROOM FROM NORTH LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 5, 2025 |
| Oct 1, 2025 | B | Apt 3R · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES ELECTRICAL FIXTURES AT CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 5, 2025 |
| Feb 25, 2022 | B | Apt 3R · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH WALL APPROXIMATELY 5 SQUARE FEET IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 14643073 ISSUED 27-OCT-21 HAS BEEN UPGRADED TO CLASS B PER ADMINIST | Apr 1, 2022 |
| Oct 28, 2021 | C | Apt 3R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 23, 2021 |
| Oct 28, 2021 | C | Apt 3R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 23, 2021 |
| Feb 6, 2020 | B | Apt 3R · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 1 SQFT AT WIDOW RECESS AT NORTH WALL, 1 SQFT AT WEST WALL AND 1 SQFT AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 3R, 3rd STORY, APARTMENT AT EAST ORIGINAL VIOLATION 13329188 ISSUED 07-OCT-19 HAS BEEN UPGRADED TO CL | Mar 12, 2020 |
| Oct 9, 2019 | C | Apt 3R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, APARTMENT AT EAST | Oct 30, 2019 |
| Oct 9, 2019 | C | Apt 3R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, APARTMENT AT EAST | Oct 30, 2019 |
| Sep 10, 2019 | C | Apt 3R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 1, 2019 |
| Sep 3, 2019 | C | Apt 3R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Sep 24, 2019 |
| Aug 17, 2018 | B | Apt 3L · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 21, 2018 |
| Date | Source | What | Now |
|---|---|---|---|
| Aug 18, 2026 | DOB | IMMEDIATE EMERGENCY: INSTALL APPROX 35 LINEAR FT OF SIDEWALK SHED ALONG THE ENTIRE FRONT OF 1 & EXTEND PAST THE BUILDING BY 5 FT ON BOTH SIDES. THE SIDEWALK SHED SHALL BE INSTALLED TIGHT BACK TO THE BUILDING AND EXTEND OVER THE SIDE WALK. EXPOSURE 1: APPROXIMATELY 35 LINEAR FT OF SIDEWALK SHED | Open |
| Aug 18, 2026 | DOB | UNSAFE BUILDINGS: | Open |
| Aug 18, 2026 | ECB | Construction: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDERS TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT OF BUILDINGS FOR VIO # 39187922M, FILE A CERTIFICATE OF CORRECTION | Open |
| Aug 18, 2026 | ECB | Construction: UNLAWFUL ACTS. FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO OBTAIN A PERMIT FOR VIO# 39187924X. NO PERMIT ON FILE FOR ERECTION OF FULL HEIGHT PARTITIONS TO CREATE 2 SEPARATE SPACES IN 3RD FL APARTMENT, CO | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 11, 2026, 3:22 AM ET. BBL 3029240055.