4 floors · 16 apartments · 8,550 sq ft · built 1920 · class C1 · owner of record: 93 Hicks Partners Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 67 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2021-05-25 (Accepted). Agency page | Dec 31, 2026 in 67 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 83 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 311 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1163 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 4, 2024 | Construction CLASS - 3 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER: AT TIME OF INSPECTION OBSERVED AT RIGHT SIDE BUILDING AT EXPOSURE #4 GUTTER AT TOP MISSING PIECE PIPE AND DISCONNECT TO STORM DRAIN SYSTEM., REPAIR AND OR #39126686K | Jan 15, 2025 DEFAULT | $500 |
| Aug 21, 2023 | Construction CLASS - 1 BC 3303.10 TENANT PROTECTION PLAN NOT BEING COMPLIED WITH NOTE: AT TIME OF INSPECTION AT ABOVE PREMISES OBSERVED WORKERS WORKING ON FACADE WITH NO WINDOW BARRIER TO PROTECT THE TENANTS FROM DUST ENTERING THEIR #35678346Y | Oct 25, 2023 DEFAULT | $6,250 |
| Oct 3, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTE:AT TIME OF INSPECTION OBSERVED IN APARTMENT 4FN HOLES IN WALLS WHERE THEY INSTALLED A SPLIT UNIT HOLE AROUND ELECTRICAL SWITCH BOX IN BEDROOM & KITCHEN #35657216N | Mar 8, 2023 IN VIOLATION | $312 |
| Sep 27, 2022 | Construction CLASS - 1 BC3303.10 FAILURE TO COMPLY WITH TENANT PROTECTION REQUIREMENTS.AT TIME OF INSPECTION OBSERVED WORK IN PROGRESS AT PREMISES UNDER PERMIT #B00628364-11GC EXPIRED 12/22/22 WORK IN PROGRESS ON 2ND, 3RD & 4TH FLOOR #35410565R | Mar 1, 2023 IN VIOLATION | $2,500 |
| Jul 8, 2022 | Construction CLASS - 2 BC3303.10 FAILURE TO COMPLY WITH TENANT PROTECTION PLAN.NOTE:AT TIME OF INSPECTION OBSERVED WORK BEING PERFORMED UNDER AFOREMENTIONED JOB NUMBER CONTRACTOR FAILED TO COMPLY WITH HEALTH REQUIREMENTS SECTION OF T #35576303R | Dec 7, 2022 IN VIOLATION | $1,250 |
| Jul 8, 2022 | Construction CLASS - 2 28-201.1 INADQUATE TENANT PROTECTION PLAN.NOTE:AT TIME OF INSPECTION OBSERVED WORK BEING PERFORMED UNDER AFOREMENTIONED JOB NUMBER SUBMITTED TPP LACKS SPECIFIC MEANS & METHODS OF PROTECTING TENANTS ON HEALTH RE #35576499H | Dec 7, 2022 IN VIOLATION | $625 |
| May 11, 2022 | Unknown CLASS - 2 UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE DEFECTIVE ELECTRICAL FIXTURE ABOVEDOOR ENTRANCE IN LOBBY COMPLY W/EC CODE #35658554K | Oct 5, 2022 IN VIOLATION | $400 |
| May 11, 2022 | Boilers CLASS - 2 NO CHIMNEY CLEAN OUT; CORRECT VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION. #39061919H | Oct 12, 2022 IN VIOLATION | $625 |
| Apr 14, 2022 | Site Safety CLASS - 1 NO ONSITE TENANT PROTECTION PLAN DETAILS.NOTE:AT TIME OF INSPECTION OF 4 STORY BUILDING TENANTS ONSITE OBSERVED NO DETAIL DOCUMENTS ONSITE INDICATING LAYOUT & PROTECTION IN PLACE FOR EACH FLOOR EACH APT & THROU #35639385P | Sep 7, 2022 IN VIOLATION | $1,250 |
| Apr 14, 2022 | Construction CLASS - 1 BC3303.7.2 NO FIRE EXSTINGUISHERS.NOTE:AT TIME OF INSPECTION OF 4 STORY BUILDING UNDER CONSTRUCTION TENANTS ONSITE OBSERVED NO FIRE EXTINGUISHERS ON ALL FLOORS.AS PER CODE FIRE EXTINGUISHERS MUST BE ONSITE DURI #35639386R | Sep 7, 2022 IN VIOLATION | $2,500 |
| Apr 14, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN.NOTE:AT TIME OF INSPECTION OF 4 STORY BUILDING UNDER CONSTRUCTION TENANTS ONSITE OBSERVED LARGE HOLE IN FACADE ABOVE DOORWAY GREEN PLASTIC HANGING DOWN WITH PLASTER ATTACHED.LACK OF MAINTENA #35639387Z | Sep 7, 2022 IN VIOLATION | $1,250 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #08184 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #07332 | DOB VIOLATION - ACTIVE |
| Apr 25, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION #10975 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Apr 25, 2023 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 2, 2026 | C | § 27-2005 ADM CODE PROVIDE APPROVED METAL SCREEN BELOW SKYLIGHT AT ROOF BULKHEAD | Sep 8, 2026 |
| Sep 2, 2026 | C | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELCTRICAL WIRES AT EAST WALL AT ROOF BULKHEAD | Sep 8, 2026 |
| Sep 2, 2026 | C | Apt 4FN · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET CLOGGED IN THE BATHROOM LOCATED AT APT 4FN, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 8, 2026 |
| Sep 2, 2026 | C | Apt 4FN · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4FN, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 8, 2026 |
| Sep 2, 2026 | C | Apt 4FN · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES ... IN THE ENTIRE APARTMENT LOCATED AT APT 4FN, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 8, 2026 |
| Sep 2, 2026 | C | Apt 4FN · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4FN, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 8, 2026 |
| Sep 2, 2026 | A | Apt 4FN · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 4FN, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 6, 2026 |
| Sep 2, 2026 | A | Apt 4FN · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR FRAME IN THE ENTRANCE LOCATED AT APT 4FN, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 6, 2026 |
| Sep 2, 2026 | C | Apt 4FN · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4FN, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 8, 2026 |
| Sep 2, 2026 | A | § 27-2049 ADM CODE POST AND MAINTAIN A STREET NUMBER ON THE FRONT OF THE DWELLING PLAINLY VISIBLE FROM THE SIDEWALK. | Dec 6, 2026 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 2, 2026 | HPD C | § 27-2005 ADM CODE PROVIDE APPROVED METAL SCREEN BELOW SKYLIGHT AT ROOF BULKHEAD | Open |
| Sep 2, 2026 | HPD C | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELCTRICAL WIRES AT EAST WALL AT ROOF BULKHEAD | Open |
| Sep 2, 2026 | HPD C | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET CLOGGED IN THE BATHROOM LOCATED AT APT 4FN, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Sep 2, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4FN, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Sep 2, 2026 | HPD C | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES ... IN THE ENTIRE APARTMENT LOCATED AT APT 4FN, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Sep 2, 2026 | HPD C | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4FN, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Sep 2, 2026 | HPD A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 4FN, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Sep 2, 2026 | HPD A | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR FRAME IN THE ENTRANCE LOCATED AT APT 4FN, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Sep 2, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4FN, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Sep 2, 2026 | HPD A | § 27-2049 ADM CODE POST AND MAINTAIN A STREET NUMBER ON THE FRONT OF THE DWELLING PLAINLY VISIBLE FROM THE SIDEWALK. | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 10:59 PM ET. BBL 3002260003.