2 floors · 11,454 sq ft · built 1946 · class M1 · owner of record: Northeastern Conf.Corp Of Seventh-Day Ad Ventists
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 17 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 425 days | Next cycle year 2027 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-06 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 5, 2008 | Elevators CLASS - 2 20Q03.08V01.16B10.77M07.40P16.20Q INSTALL GRILLS ON ALL VISION GLASS 16B LOBBY & 3FL HINGES 77M TOE GUARD #38193032P | Dec 29, 2008 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Oct 1, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT #07441 | DOB VIOLATION - ACTIVE |
| Oct 29, 2008 | ELEVATOR #9011/283746 | DOB VIOLATION - ACTIVE |
| Nov 1, 2007 | ELEVATOR #9011/224349 | DOB VIOLATION - ACTIVE |
| Dec 12, 2006 | ELEVATOR #9011/182971 | DOB VIOLATION - ACTIVE |
| Jan 31, 2005 | LOCAL LAW 62/91 - BOILERS #15503 | DOB VIOLATION - ACTIVE |
| Mar 8, 2004 | ELEVATOR #9011/393751 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #21125 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #28049 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 17) | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Report | Active |
| Apr 5, 2019 | Elevators EVCAT1 | Active |
| Jan 26, 2018 | Elevators ACC1 | Active |
| Dec 1, 2016 | Elevators EVCAT1 | Active |
| Jun 1, 2016 | Elevators EVCAT5 | Active |
| Oct 1, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT | Active |
| Jun 10, 2015 | Elevators EVCAT1 | Active |
| Oct 31, 2014 | Elevators EVCAT1 | Active |
| Mar 31, 2014 | Elevators EVCAT1 | Active |
| Oct 1, 2012 | Elevators EVCAT1 | Active |
| Apr 2, 2007 | Elevators LL1081 | Active |
| Oct 1, 2005 | Elevators LL1081 | Active |
| Jan 31, 2005 | Boiler LL6291 | Active |
| Nov 19, 2004 | Elevators LL1081 | Active |
| Apr 21, 2004 | Elevators LL1081 | Active |
| Mar 21, 2003 | Elevators LL1081 | Active |
| Mar 19, 2003 | Boiler LL6291 | Active |
| Mar 8, 2001 | Elevators LL1081 | Active |
| Mar 10, 2000 | Elevators LL1081 | Active |
| Jan 6, 1998 | Elevators LL1081 | Active |
| Jan 13, 1997 | Elevators LL1081 | Active |
| Mar 8, 1996 | Elevators LL1081 | Active |
| May 31, 1994 | Elevators LL1081 | Active |
| Jun 28, 1993 | Elevators LL1081 | Active |
| Apr 7, 1992 | Elevators LL1081 | Active |
| Apr 25, 1991 | Elevators LL1081 | Active |
| Jun 29, 1990 | Elevators LL1081 | Active |
| Oct 12, 1989 | Elevators LL1081 | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 11:44 PM ET. BBL 3051280054.