Brooklyn · Block 6108 · Lot 22 · 11209

9201 4 Avenue

7 floors · 79,173 sq ft · built 1965 · class O6 · owner of record: 9201 Llc

72open violations
$48,480ECB/OATH penalties owed
0HPD class C (immediately hazardous)
65dto Annual boiler inspection (1 boiler)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 65 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-11-06 (Accepted). Agency page

Dec 31, 2026
in 65 days
1 of 1 without an accepted 2026 report yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 79,173 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 186 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 186 days
Annual filing
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page

Feb 21, 2028
in 482 days
No Cycle 10 report on record yet
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 796 days
Next cycle year 2028
Energy audit and retro-commissioning (2028) Likely applies
Local Law 87 · Calendar year 2028
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 6108). Agency page

Dec 31, 2028
in 796 days
Next due 2028

Open violations

ECB / OATH (22) · $48,480 owed
IssuedViolationHearingBalance
May 5, 2026Construction CLASS - 2
AT TIME OF INSPECTION IN RESPONSE TO COMPLAINT I OBSERVED UNDERSIDE OF SIDEWALK SHED A NOT ILLUMINATED AS PER 3307.6.4.8. ON 5TH AVE OF THE SITE. THIS CREATES A HAZARDOUS CONDITION FOR PUBLIC WALKING UNDERNEATH
#39553789J
Jul 15, 2026
IN VIOLATION
$2,400
Sep 4, 2025Construction CLASS - 2
SHARP EDGE BC3307.6.5.6.@7 STORY BUILDING W/NO VALID BUILDING CONSTRUCTION PERMIT OBSERVED PEDESTRIAN PROTECTION SIDEWALK SHEDS VERTICAL MEMBERS SHARP EDGES (BOLTS) MISSING PROTECTION (CAPS) TO CODE BC3307.6.5.
#39544454N
Dec 12, 2025
IN VIOLATION
$2,400
Nov 26, 2024Construction CLASS - 1
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER#35686170J REQUESTING IMMEDIATELY INSTALLATION OF SAFETY MEASURES.AT TIME OF INSPECTION WATER INFILTRATION,CRACKED CONCRETE FLOOR SLAB,DETERIORATED SPALLING AND MISSIN
#35686972L
Mar 31, 2025
IN VIOLATION
$2,500
Oct 1, 2024Construction CLASS - 1
FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE OR A PERIODIC INSPECTION OF A PARKING STRUCTURE(PIPS) REPORT DOCUMENTING THE CONDITIONS OF PSID#B000
#37031283L
Feb 5, 2025
IN VIOLATION
$2,500
Sep 3, 2024Construction CLASS - 1
28-323.8 AND RCNY 103-13. FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING'S STRUCTURE AND APPURTENANCES CONFORM TO THE PROVISIONS OF THE ADMIN CODE AFTER UNSAFE NOTIFICATION FILED BY QPSI #UNPS-BOOO294
#35686170J
Mar 31, 2025
IN VIOLATION
$2,500
Aug 24, 2022Construction CLASS - 2
AT TIME OF INSPECTION, OBSERVED AN ERECTED SIDEWALK SHED AT EXPOSURES 1,2,4 WITH VALID PERMIT, OBSERVED AT EXPOSURE # 4 SIDEWALK SHED NOT EXTENDED 5 FEET PAST TO PROTECT ADJACENT PROPERTY, THE 24 HOUR PARKING E
#39505449R
Dec 28, 2022
IN VIOLATION
$2,400
Feb 28, 2022Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS OR APPURTENANCES.NOTE:RESPONDENT FAILED TO CORRECT PREVIOUSLY ISSUED ECB#35635595P DATED ON 11/30/2021 AND ECB#35635119Y DATED ON 01/11/2022.AS OF TODAY,02/28/2022,NO
#35647432Z
Nov 18, 2022
IN VIOLATION
$12,500
Jan 11, 2022Construction CLASS - 1
FAILURE TO MAINTAIN BLDG EXTERIOR FACADE&APPURTENANCES AS NOTED BLDG FAILED TO MAKE NECESSARY REPAIRS TO FACADE TO CORRECT CONDITIONS SITED IN SUMMONS35635595P ISSUED11/30/21 AS OF 1/11/22 NO REPAIRS HAVE BEEN
#35635119Y
Jun 29, 2022
IN VIOLATION
$3,125
Nov 30, 2021Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BLDG FACADE&APPURTENANCES.(1)@ROOF LEVEL OBSERVED CRACKED&DAMAGED MORTAR JOINTS@BULKHEAD WESTERN SOUTH CORNER.(2)@N ELEVATION,EXP1 SPALLED BRICKS&DAMAGED/OPEN MORTAR JOINTS@MULTIPLE
#35635595P
Aug 1, 2022
IN VIOLATION
$12,500
Oct 16, 2021Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS/FACADE AND APPURTENANCES.VIEW AT EXP #1 DAMANGED AND OPEN MORTAR JOINTS EXP #2 DAMAGED JOINTS CRACK DETERIORATION AND CORNER OF EXP #1 #3 #4 CRACK DETERIORATOIN AT CO
#35635413P
Aug 5, 2022
IN VIOLATION
$2,500
Sep 16, 2021Construction CLASS - 2
I OBSERVED IN BACK ROOM IN BASEMENT PARKING GARAGE WASTE AND RAIN WATER BACKING UP AND RUNNING DOWNSTAIRS WHERE CARS ARE PARKED AND PUMPS NOT WORKING WHICH NOT ALLOWING THE WATER TO BE PUMPED OUT WHICH IS PROHI
#39047603K
Jan 19, 2022
IN VIOLATION
$312
Sep 4, 2021Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BLDGS FACADE&APPURTENANCES.@N ELEVATION,EXP1 OBSERVED CRACKED BRICKS;MULTIPLE AREAS OF DAMAGED/OPEN MORTAR JOINTS.@E ELEVATION,EXP2 OBSERVED DAMAGED/OPEN MORTAR JOINTS.@W ELEVATION,
#35588869Y
May 2, 2022
IN VIOLATION
$343
Jul 26, 2021Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE:OBSERVED AT EXPOSURE#1(NORTH) CRACKED BRICKS,MULTIPLE AREAS OF DAMAGED/OPEN MORTAR JOINTS. 2)EXPOSURE#2(EAST) DAMAGED/OPEN MORTAR JOINTS. 3)E
#35578084P
Jan 10, 2022
IN VIOLATION
$2,500
Apr 28, 2021Elevators CLASS - 2
REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. SELF RESETTING ESCAPE HATCH SWITCHES PROHIBITED. MAIN LINE CAN BE OPENED WHEN POWER ON. GOV MISSING SEALS. REMOVE NON ELEVATOR ITEMS FROM MACHINE ROOM.
#39040280N
Sep 15, 2021
IN VIOLATION
$0
Jun 20, 2017Unknown CLASS - 2
FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000000932 HASBEEN INSPECTED,TESTED,AND DISINFECTED,AND THAT A MAINTENANCE PLAN HAS BEEN DEVELOPED AND IMPLEMENTED BY NOVEMBER 1,2016.REM:FILE ANNUAL CERT
#37003426L
Jun 6, 2018
IN VIOLATION
$0
Nov 1, 2013Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:AT PARKING GARAGE BOTH LEVEL- CELLAR & SUBCELLAR ARE DEFECTS; AT UNDERSIDE OF FLOORINGSLAB ARE IN STATE OF DISREPAIR,I.E. SPALLING,DETERIORATION OF STEEL
#35030520Z
Feb 3, 2014
DEFAULT
$0
Jan 23, 2012Construction CLASS - 3
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT 6TH FL LEVEL DOCTOR'S OFFICE EVIDENCE OF WATER LEAKS WITH DAMAGES TO INTERIOR FINISHES AROUND PERIMETER EXTERIOR WINDOW
#34943153X
Apr 2, 2012
IN VIOLATION
$0
Dec 21, 2011Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING: NOTED SEVERLY CORRODED Q-DECK CEILINGS THROUGHOUT CAUSING FIRE PROOFING TO DETACH AND FALL. REMEDY: MAINTAIN BUILDING
#34933747Y
Feb 6, 2012
WRITTEN OFF
$0
Jun 20, 2011Construction CLASS - 3
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER 6TH FL WATER STAIRS IN 1. CORRIDOR LIGHT FIXTURES 2. DOCTORS OFFICES CEILING TILES 3. POSSIBLE WINDOW WATER PENETRATION REM: PROVIDE REGISTERED ARCHITECT REPORT
#34918361X
Aug 8, 2011
WRITTEN OFF
$0
Jan 28, 2011Construction CLASS - 2
FAILURE TO COMPLY W/THE COMM'S ORDER TO FILE A COFC W/THE DOB RESPONDENT FAILED TO CORRECT THE VIOLATING CONDITION & FILE A COFC,PURSUANT TO28-204.2 FOR NOV#34806726X.REM:FILE COFC
#34900002Z
Jul 11, 2011
WRITTEN OFF
$0
Nov 1, 2010Construction CLASS - 1
FAILURE TO MAINTAIN BLDG WALLS & APPURTENANCES.NOTED:@ EAST ELEVATION @ 6 FLR PARAPET THERE ARE 2 DEFLECTION OF APPROX 2" @ THE EXPANSION JOINTS CAUSING WATER SEEPAGE & DAMAGE @ 6FLR OFFICES.7 FLR ROOT PARAPET
#34886726X
Jul 11, 2011
IN VIOLATION
$0
Jul 27, 2010Construction CLASS - 3
FAILURE TO MAINTAIN BLDG IN CODE NOTED:@ 6TH FLR WINDOWS @ VARIOUS LOCATION HAVE CRACKS & WATER DAMAGE WATER LEAKS FROM THE CRACKS AROUND.REM:REPAIR OR REPLACE
#34861469N
Sep 20, 2010
WRITTEN OFF
$0
DOB (26)
IssuedViolationStatus
Sep 18, 2026CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AT EXP 1,2,3 AND 4 DAMAGED AND MISSING MORTAR JOINTS AT MULTIPLE LOCATIONS. REMEDY: REPAIR AND/OR REPLACE DEFECTED AREAS. REMEDY: REPAIR AND/OR REPLACE DEFECTED AREAS
#SR1003BS
DOB VIOLATION - ACTIVE
Dec 8, 2025CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AS NOTED AT TIME OF INSPECTION,I OBSERVED ON EXP1,2,3,4 DAMAGED MORTAR JOINTS,MISSING M ORTAR JOINTS AT MULTIPLE PARAPETS.EXP4 SOUTH ELEV,I OBSERVED BULGING B RICK ON 2ND FLOOR.REMEDY:REPAIR AND/OR REPLACE ALL DAMAGED FACADE MASO NRY
#SR1002RF
DOB VIOLATION - ACTIVE
Dec 8, 2025CONSTRUCTION
EMERGENCY WORK ORDER DUE TO BULGING BRICKS ON EXP#3 SOUTH ELEVATION.AS NOTED AT INSPECTION 2 OBSERVED SECTION OF BULGING BRICKS AT ABOUT 2FL HEIGHT, SIZE OF BULGING BRICKS, APPROXIMATELY 12 FEET X 3 FEET REMEDY: PROVIDE ADEQUATE SAFETY MEASURES IN THE AREA OF THE BULGING ON EXPOSURE AND BEGIN IMMEDI
#SR0103RF
DOB VIOLATION - ACTIVE
Dec 8, 2025CONSTRUCTION
100% HANDS ON INSPECTION: EXP #3 SOUT ELEVATION & BULGING BRICKS @ 2FL SIZE OF BULGING BRICKS APPROXIMAELY 12' BY 3'. REMEDY/REQUIREMENT:- OWNER TO IMMEDIATELY RETAIN NYS LIC, PROFESSIONAL A RDP W/QEWI CERTIFICATION TO PERFORM 100% HANDS ON INSPECTION OF ENTIRE MASONRY FACE @ ALL 4 EXPOSURES AND TO
#SR1003RF
DOB VIOLATION - ACTIVE
Oct 30, 2025CONSTRUCTION
STRUCTURE RENDERED NONCOMPLIANCE. INCIDENT WHERE MTA BUS STRUCK SIDEWALK SHED LOCATE IT ON THE CORNER OF 4 AVE AND 92 STREET. SWS PERMIT B00773002-I2-SH EXPIRES 01/10/26. SECTION THAT WAS DAMAGED TO BE PAIRED OR REPLACED.
#25-02450
DOB VIOLATION - ACTIVE
Mar 5, 2025FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00211
DOB VIOLATION - ACTIVE
Nov 13, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00094
DOB VIOLATION - ACTIVE
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#12361
DOB VIOLATION - ACTIVE
Sep 3, 2024CONSTRUCTION
EMERGENCY WORK ORDER ON ACTIVE P.S. CONSISTING OF 23 LEVELS (CEL/SUB CELLAR) CRACKED CONCRETE SLAB-SUB-CEL, CORRODED METAL DECKING EXPOSE CRACKED SPALLING/CONCRETE/EXPOSED CORRODED STEEL REINFORCEMENTS MULT LOC @ SOFFIT. REMEDY: INSTALLATION OF SAFETY MEAS, ALL WORK UNDER SUPERVISION OF RDP. PROG RE
#FA31001DD
DOB VIOLATION - ACTIVE
Apr 26, 2023CONSTRUCTION
FIRE STOPPING AT STEEL BEAMS AND METAL SHEETING MISSING THROUGHOUT THE GARAGE. PLUMBING LEAK OBSERVED.
#23-01207
DOB VIOLATION - ACTIVE
Apr 25, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
#15052
DOB VIOLATION - ACTIVE
Mar 2, 2022FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00361
DOB VIOLATION - ACTIVE
Jan 5, 2022FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00350
DOB VIOLATION - ACTIVE
Oct 27, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00374
DOB VIOLATION - ACTIVE
Apr 16, 2021ELEVATOR

#9028/692973
DOB VIOLATION - ACTIVE
Apr 16, 2021ELEVATOR

#9028/692972
DOB VIOLATION - ACTIVE
May 4, 2020ELEVATOR

#9028/680325
DOB VIOLATION - ACTIVE
May 4, 2020ELEVATOR

#9028/680324
DOB VIOLATION - ACTIVE
Sep 6, 2019(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
#11168
DOB VIOLATION - ACTIVE
Jan 3, 2017(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
#12717
DOB VIOLATION - ACTIVE
Jan 3, 2017(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
#12716
DOB VIOLATION - ACTIVE
Nov 14, 2016(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
#13811
DOB VIOLATION - ACTIVE
Nov 14, 2016(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
#13812
DOB VIOLATION - ACTIVE
Oct 19, 2008CONSTRUCTION

#ER01LP
VIOLATION WORK WITHOUT PERMIT - ACTIVE
Nov 1, 2000ELEVATOR

#9011/328383
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#31818
DOB VIOLATION - ACTIVE
DOB NOW Safety (26)
IssuedViolationStatus
Sep 23, 2026Parking Structures FTF-PS-INITL
Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Sep 26, 2025Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Mar 5, 2025AEUHAZ FTC-AEU-HAZ
Active
Nov 13, 2024AEUHAZ FTC-AEU-HAZ
Active
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
Sep 11, 2024Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Report
Active
Sep 11, 2024Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Report
Active
Aug 25, 2023Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Report
Active
Aug 25, 2023Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Report
Active
Apr 25, 2023Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT
Active
Mar 2, 2022AEUHAZ FTC-AEU-HAZ
Active
Jan 5, 2022AEUHAZ FTC-AEU-HAZ
Active
Oct 27, 2021AEUHAZ FTC-AEU-HAZ
Active
Sep 6, 2019Elevators ACC1
Active
Jan 3, 2017Elevators ACC1
Active
Jan 3, 2017Elevators ACC1
Active
Nov 14, 2016Elevators ACC1
Active
Nov 14, 2016Elevators ACC1
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 23, 2026DOB SafetyParking Structures: Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13Open
Sep 18, 2026DOBCONSTRUCTION: FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AT EXP 1,2,3 AND 4 DAMAGED AND MISSING MORTAR JOINTS AT MULTIPLE LOCATIONS. REMEDY: REPAIR AND/OR REPLACE DEFECTED AREAS. REMEDY: REPAIR AND/OR REPLACE DEFECTED AREASOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 27, 2026, 12:12 AM ET. BBL 3061080022.