4 floors · 61,780 sq ft · built 2015 · class K4 · owner of record: Andon Investment Limited Partnership
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 68 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 61,780 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 189 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 189 days | Annual filing |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2075). Agency page | Dec 31, 2035 in 3355 days | Next due 2035 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 16, 2026 | Construction CLASS - 1 ATOI OBSERVED ON THE ROOF GAS PIPING NEEDING TO BE MAINTAINED SOME PARTS NOT PAINTED ALSO SOME PARTS RUSTED. GAS PIPE MUST BE PROPERLY MAINTAINED AT ALL TIMES., REPAIR AND/REPLACE #39204423J | Nov 24, 2026 PENDING | $2,500 |
| Sep 16, 2026 | Construction CLASS - 1 ATOI OBSERVED IN THE GARAGE AREA A MAKE SHIFT CAR DETAILING SHOP IN WHICH THEY HAD A HOSE PULLING WATER FROM A HOSE BIB CONNECTED TO THE FIRE SUPPRESSION SYSTEM BOOSTER PUMP PIPING., REPAIR AND/REPLACE #39204427R | Nov 24, 2026 PENDING | $2,500 |
| Sep 16, 2026 | Construction CLASS - 1 ATOI OBSERVED THE WATER HEATERS ON THE 3RD AND 4TH FLOOR BEING HOUSED IN A TIGHT CLOSET NOT ALLOWING ACCESS TO THE WATER HEATERS FOR SERVICE OR REPAIR. CONTRARY TO - FGC 306.1 - APPLIANCES AND ASSOCIATED COMPON #39204425N | Nov 24, 2026 PENDING | $2,500 |
| Sep 16, 2026 | Elevators CLASS - 2 CLASS 2: FIREFIGHTER'S SERVICE PHASE II - PHASE II DOES NOT BYPASS RESTRICTED ACCESS TO FLOOR 2, FAILING REQUIRED FIRE EMERGENCY ACCESS FUNCTION. AS PER ASME A17.1 2.27. REMEDY: RESTORE PROPER PHASE II OPERATIO #39204312R | Nov 24, 2026 PENDING | $625 |
| Sep 16, 2026 | Construction CLASS - 1 ATOI OBSERVED HOT WATER HEATERS ON THE 3RD & 4TH FLOORS INSTALLED USING PVC ON THE FRESH AIR INTAKES AND ON THE THIRD FLOOR THE FRESH AIR IS BEING VENTED INTO THE HALLWAY RATHER THEN FROM OUT SIDE THE BUILDING #39204424L | Nov 24, 2026 PENDING | $2,500 |
| Sep 16, 2026 | Elevators CLASS - 2 CLASS 2: 1. TOP-OF-CAR OUTRIGGING - OUTRIGGING NOT SECURED, CREATING AN UNSAFE TOP-OF-CAR CONDITION. AS PER ASME A17.1 8.6. REMEDY: SECURE OUTRIGGING AND VERIFY SAFE TOP-OF-CAR ACCESS. 2. OIL ON TOP OF CAR AND #39204313Z | Nov 24, 2026 PENDING | $625 |
| Sep 16, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION OBSERVED PVC BEING USED FOR DRAINAGE IN THE THE FIRE PUMP ROOM. CONTRARY TO PC 701.9 PLASTIC PIPING AND FITTINGS SHALL NOT BE USED., REPAIR AND/OR REPLACE #39204426P | Nov 24, 2026 PENDING | $1,250 |
| Sep 16, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLE PENETRATIONS, PLASTIC ACCESS PANELS. LOCATED THROUGHOUT BUILDING., REPAIR AND/REPLACE #39204605K | Nov 24, 2026 PENDING | $2,500 |
| Sep 16, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED UNPROHIBITED HARDWARE ON PUBLIC CORRIDOR DOOR. POTENTIAL HAZARD IN AN EMERGENCY., REPAIR AND/OR REPLACE #39204604Z | Nov 24, 2026 PENDING | $1,250 |
| Sep 16, 2026 | Construction CLASS - 1 ATOI OBSERVED THE THIRD FLOOR WATER HEATER INSTALLED WITHOUT ANY PERMITS FILED ON BIS OR DOBNOW CONTRARY TO PC 106.1 PLUMBING WORK INCLUDING WATER HEATER INSTALLATIONS AND PLUMBING SYSTEM ALTERATIONS, REQUIRES #39204422H | Nov 24, 2026 PENDING | $2,500 |
| Sep 23, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATIONS THROUGHOUT FLOORS 4,3 AND 1. COVERED WITH PROBHITED PL #39161276L | Oct 29, 2026 DEFAULT | $1,280 |
| Sep 23, 2025 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING. LOCATED ON 3RD FLOOR, EMERGENCY EXIT DOOR NOT FUNCTIONING PROPERLY. DOOR DOES NOT OPEN ALL THE BECAUSE OF THE ARM ON TOP OF THE DOOR DEFECTIVE. POTENTIAL FIRE HAZARD., REPAIR/REPLACE #39161275J | Oct 29, 2026 DEFAULT | $655 |
| Sep 23, 2025 | Elevators CLASS - 2 CLASS 2 ITEMS: IN-CAR ALARM INOPERATIVE, REPAIR. 4 FLOOR DOOR LOCK COVER HANGING ON A SINGLE SCREW, SECURE. HOIST ROPE TAILS EXTRA LONG, SHORTEN AND SECURE. #39161271M | Dec 2, 2025 STIPULATION/IN-VIO | $310 |
| Sep 23, 2025 | Elevators CLASS - 2 CLASS 2 ITEMS: MAIN LINE SWITCH FRONT PANEL IS NOT LOCKABLE IN THE CLOSED POSITION WHEN THE POWER IS ON, REPAIR. HOIST ROPE TAILS TOO LONG, SHORTEN AND SECURE. #39161270K | Dec 2, 2025 STIPULATION/IN-VIO | $310 |
| Aug 25, 2014 | Construction CLASS - 1 3309.9 WHEATHER PROOFING INTEGRITY OF ADJOINING BLDG.@ TIME OF INSP.OF DEMO,SITE NOTED THAT @ EXP.#2 THE ADJOINING PROPERTY HAD NOT BEEN WEATHER PROOFED PROPERLY.THERE ARE OPENINGS BETWEEN THE CINDER BLOCKS THA #35098645N | Apr 28, 2015 WRITTEN OFF | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 6) | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 16, 2026 | ECB | Construction: ATOI OBSERVED ON THE ROOF GAS PIPING NEEDING TO BE MAINTAINED SOME PARTS NOT PAINTED ALSO SOME PARTS RUSTED. GAS PIPE MUST BE PROPERLY MAINTAINED AT ALL TIMES., REPAIR AND/REPLACE | Open |
| Sep 16, 2026 | ECB | Construction: ATOI OBSERVED IN THE GARAGE AREA A MAKE SHIFT CAR DETAILING SHOP IN WHICH THEY HAD A HOSE PULLING WATER FROM A HOSE BIB CONNECTED TO THE FIRE SUPPRESSION SYSTEM BOOSTER PUMP PIPING., REPAIR AND/REPLACE | Open |
| Sep 16, 2026 | ECB | Construction: ATOI OBSERVED THE WATER HEATERS ON THE 3RD AND 4TH FLOOR BEING HOUSED IN A TIGHT CLOSET NOT ALLOWING ACCESS TO THE WATER HEATERS FOR SERVICE OR REPAIR. CONTRARY TO - FGC 306.1 - APPLIANCES AND ASSOCIATED COMPON | Open |
| Sep 16, 2026 | ECB | Elevators: CLASS 2: FIREFIGHTER'S SERVICE PHASE II - PHASE II DOES NOT BYPASS RESTRICTED ACCESS TO FLOOR 2, FAILING REQUIRED FIRE EMERGENCY ACCESS FUNCTION. AS PER ASME A17.1 2.27. REMEDY: RESTORE PROPER PHASE II OPERATIO | Open |
| Sep 16, 2026 | ECB | Construction: ATOI OBSERVED HOT WATER HEATERS ON THE 3RD & 4TH FLOORS INSTALLED USING PVC ON THE FRESH AIR INTAKES AND ON THE THIRD FLOOR THE FRESH AIR IS BEING VENTED INTO THE HALLWAY RATHER THEN FROM OUT SIDE THE BUILDING | Open |
| Sep 16, 2026 | ECB | Elevators: CLASS 2: 1. TOP-OF-CAR OUTRIGGING - OUTRIGGING NOT SECURED, CREATING AN UNSAFE TOP-OF-CAR CONDITION. AS PER ASME A17.1 8.6. REMEDY: SECURE OUTRIGGING AND VERIFY SAFE TOP-OF-CAR ACCESS. 2. OIL ON TOP OF CAR AND | Open |
| Sep 16, 2026 | ECB | Construction: AT THE TIME OF INSPECTION OBSERVED PVC BEING USED FOR DRAINAGE IN THE THE FIRE PUMP ROOM. CONTRARY TO PC 701.9 PLASTIC PIPING AND FITTINGS SHALL NOT BE USED., REPAIR AND/OR REPLACE | Open |
| Sep 16, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLE PENETRATIONS, PLASTIC ACCESS PANELS. LOCATED THROUGHOUT BUILDING., REPAIR AND/REPLACE | Open |
| Sep 16, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED UNPROHIBITED HARDWARE ON PUBLIC CORRIDOR DOOR. POTENTIAL HAZARD IN AN EMERGENCY., REPAIR AND/OR REPLACE | Open |
| Sep 16, 2026 | ECB | Construction: ATOI OBSERVED THE THIRD FLOOR WATER HEATER INSTALLED WITHOUT ANY PERMITS FILED ON BIS OR DOBNOW CONTRARY TO PC 106.1 PLUMBING WORK INCLUDING WATER HEATER INSTALLATIONS AND PLUMBING SYSTEM ALTERATIONS, REQUIRES | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 12:41 AM ET. BBL 4020750039.