Queens · Block 10101 · Lot 27 · 11433

92-32 Union Hall Street

8 floors · 66,392 sq ft · built 1931 · class H3 · owner of record: New Chrystie Llc

6open violations
$33,475ECB/OATH penalties owed
0HPD class C (immediately hazardous)
171dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 50 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 66,392 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 171 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 171 days
Annual filing
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 415 days
Next cycle year 2027
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $66,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2029
in 833 days
Filing window not open yet
Energy audit and retro-commissioning (2031) Likely applies
Local Law 87 · Calendar year 2031
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 10101). Agency page

Dec 31, 2031
in 1876 days
Next due 2031
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-16 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (10) · $33,475 owed
IssuedViolationHearingBalance
Aug 10, 2026Construction CLASS - 1
ATOI OBSERVED IN THE ROOM MECHANICAL ROOM A WATER HEATER WAS INSTALLED BEHIND ANOTHER AND BOXED IN WITH NO ROOM OR ACCESS FOR REPAIR/REPLACEMENT/SERVICE. ALSO PVC ON BOILER EXHAUST. CONTRARY TO MC 306 - ACCESS
#39199902N
Dec 15, 2026
PENDING
$2,500
Aug 10, 2026Construction CLASS - 1
ATOI OBSERVED THROUGH OUT THE BUILDING OBSTRUCTED SPRINKLER HEADS AND MISSING SPRINKLER CAPS ALL SPRINKLER HEADS MUST BE FREE OF OBSTRUCTIONS CONTRARY TO BC 903.3 - INSTALLATION REQUIREMENTS FOR AUTOMATIC SPRIN
#39199904R
Dec 15, 2026
IN VIOLATION
$2,500
Aug 10, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE -COMPLIANT MANNER. ATOI I OBSERVED AT EXPOSURE#4 THE WALL FACADE IS IN DISREPAIR FROM THE GROUND LEVEL UP TO THIS 4TH FLOOR LEVEL, LOOSE BRICK WITH MISSING MORTAR AN THE CHI
#39199878M
Dec 15, 2026
IN VIOLATION
$2,500
Aug 10, 2026Elevators CLASS - 1
CLASS 1 C/U: 1. ROPE GRIPPER DISABLED BY A SET SCREW, PREVENTING PROPER EMERGENCY FUNCTION. AS PER ASME A17.1 2.19. REMEDY FOR CLASS 1: CORRECT ALL CONDITIONS. LOAD TEST REQUIRED TO LIFT THE C/U ORDER. REINSPEC
#39199849N
Dec 15, 2026
IN VIOLATION
$1,250
Aug 10, 2026Unknown CLASS - 1
UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN STAIRWAY B THE SMOKE PURGE IS HANGING FROM CEILING THE LOUVERS ARE BROKEN NEEDS TO BE I
#39199901L
Dec 15, 2026
IN VIOLATION
$1,600
Aug 5, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: IMPROPER EXIT/EXIT ACCESS DOORWAY ARRANGEMENT PER BC 1014.2 (2008 CODE); 27-361; BC 1015.2 (2014 CODE); BC 1016.1 (2022 CODE).OBSERVE HOLES PENETRATIONS. L
#39155994P
Nov 25, 2025
IN VIOLATION
$625
Apr 30, 2024Elevators CLASS - 1
ELECTRICAL BRAKE SWITCHES NOT WORKING IT'S NOT WIRED TO THE CONTROLLER OR BRAKE SWITCHS(CU). EMERGENCY ALARM BELL NO BUZZER. EMERGENCY STOP SWITCH NO BUZZER.
#39112995R
Aug 13, 2024
IN VIOLATION
$1,250
Apr 30, 2024Elevators CLASS - 1
ELECTRICAL BRAKE SWITCHES NOT WORKING TAMPERED WITH DISABLED(CU). MISSING HIGH HAT LIGHT IN THE CAR DOME OPEN HOLE IN THE CEILING. EMERGENCY ALARM BELL NO BUZZER. EMERGENCY STOP SWITCH NO BUZZER. REMOVE GARBAGE
#39112996Z
Aug 13, 2024
IN VIOLATION
$1,250
Oct 9, 2019Site Safety CLASS - 1
FAILUER TO HAVE CONSTRUCTION SUPERINTENDENT PRESENT OR DUTIES OF SITE DURING CONSTRUCTION.NOTE:AT TIME OF MY INSPECTOIN OF A 8 STORY BUILDING,ROOF LEVEL UNDER CONSTRUCTION WORK IN PROGRESS UPON REQUEST FOR CONS
#35424184K
Jun 2, 2020
IN VIOLATION
$10,000
Apr 24, 2019Site Safety CLASS - 1
FAILURE TO DESIGNATE COMPETENT PERSON ON SITE: @TIME OF INSPECTION, I OBSERVED WORKERS ON 4TH FLOOR & REAR YARD @EXP#3:THE SECURITY INFORMEDME, THE SUPER NOR COMPETENT PERSON WAS PRESENT ON SITE.SITE IS ACTIVE
#35405410X
Dec 3, 2019
IN VIOLATION
$10,000
DOB (2)
IssuedViolationStatus
Feb 22, 2024NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
#01132
DOB VIOLATION - ACTIVE
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#04079
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Feb 22, 2024Facades FISPNRF
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Aug 10, 2026ECBConstruction: ATOI OBSERVED IN THE ROOM MECHANICAL ROOM A WATER HEATER WAS INSTALLED BEHIND ANOTHER AND BOXED IN WITH NO ROOM OR ACCESS FOR REPAIR/REPLACEMENT/SERVICE. ALSO PVC ON BOILER EXHAUST. CONTRARY TO MC 306 - ACCESSOpen
Aug 10, 2026ECBConstruction: ATOI OBSERVED THROUGH OUT THE BUILDING OBSTRUCTED SPRINKLER HEADS AND MISSING SPRINKLER CAPS ALL SPRINKLER HEADS MUST BE FREE OF OBSTRUCTIONS CONTRARY TO BC 903.3 - INSTALLATION REQUIREMENTS FOR AUTOMATIC SPRINClosed
Aug 10, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING IN CODE -COMPLIANT MANNER. ATOI I OBSERVED AT EXPOSURE#4 THE WALL FACADE IS IN DISREPAIR FROM THE GROUND LEVEL UP TO THIS 4TH FLOOR LEVEL, LOOSE BRICK WITH MISSING MORTAR AN THE CHIOpen
Aug 10, 2026ECBConstruction: ATOI OBSERVED THROUGH OUT STAIRCASE B ON THE FIRE SPRINKLER HOSE CONNECTION HAS THE USE OF PLASTIC CAPS ALL CAPS MUST BE METAL NO PLASTIC, REPAIR AND/OR REPLACEClosed
Aug 10, 2026ECBUnknown: FAILURE TO PROVIDE/MAINTAIN SUFFICIENT ACCESS/WORK SPACE ABOUT ELECTRICAL EQUIPMENT. OBSERVED IN THE BASEMENT IN THE ATS RM EXCESSIVE STORAGE OF BUILDING MATERIALS AND CONSTRUCTION MATERIALS LADDERS, BUCKETS, TClosed
Aug 10, 2026ECBElevators: CLASS 1 C/U: 1. ROPE GRIPPER DISABLED BY A SET SCREW, PREVENTING PROPER EMERGENCY FUNCTION. AS PER ASME A17.1 2.19. REMEDY FOR CLASS 1: CORRECT ALL CONDITIONS. LOAD TEST REQUIRED TO LIFT THE C/U ORDER. REINSPECClosed
Aug 10, 2026ECBUnknown: UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN STAIRWAY B THE SMOKE PURGE IS HANGING FROM CEILING THE LOUVERS ARE BROKEN NEEDS TO BE IOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 11, 2026, 5:37 PM ET. BBL 4101010027.