8 floors · 66,392 sq ft · built 1931 · class H3 · owner of record: New Chrystie Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 50 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 66,392 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 171 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 171 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 415 days | Next cycle year 2027 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $66,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2029 in 833 days | Filing window not open yet |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 10101). Agency page | Dec 31, 2031 in 1876 days | Next due 2031 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-16 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 10, 2026 | Construction CLASS - 1 ATOI OBSERVED IN THE ROOM MECHANICAL ROOM A WATER HEATER WAS INSTALLED BEHIND ANOTHER AND BOXED IN WITH NO ROOM OR ACCESS FOR REPAIR/REPLACEMENT/SERVICE. ALSO PVC ON BOILER EXHAUST. CONTRARY TO MC 306 - ACCESS #39199902N | Dec 15, 2026 PENDING | $2,500 |
| Aug 10, 2026 | Construction CLASS - 1 ATOI OBSERVED THROUGH OUT THE BUILDING OBSTRUCTED SPRINKLER HEADS AND MISSING SPRINKLER CAPS ALL SPRINKLER HEADS MUST BE FREE OF OBSTRUCTIONS CONTRARY TO BC 903.3 - INSTALLATION REQUIREMENTS FOR AUTOMATIC SPRIN #39199904R | Dec 15, 2026 IN VIOLATION | $2,500 |
| Aug 10, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE -COMPLIANT MANNER. ATOI I OBSERVED AT EXPOSURE#4 THE WALL FACADE IS IN DISREPAIR FROM THE GROUND LEVEL UP TO THIS 4TH FLOOR LEVEL, LOOSE BRICK WITH MISSING MORTAR AN THE CHI #39199878M | Dec 15, 2026 IN VIOLATION | $2,500 |
| Aug 10, 2026 | Elevators CLASS - 1 CLASS 1 C/U: 1. ROPE GRIPPER DISABLED BY A SET SCREW, PREVENTING PROPER EMERGENCY FUNCTION. AS PER ASME A17.1 2.19. REMEDY FOR CLASS 1: CORRECT ALL CONDITIONS. LOAD TEST REQUIRED TO LIFT THE C/U ORDER. REINSPEC #39199849N | Dec 15, 2026 IN VIOLATION | $1,250 |
| Aug 10, 2026 | Unknown CLASS - 1 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN STAIRWAY B THE SMOKE PURGE IS HANGING FROM CEILING THE LOUVERS ARE BROKEN NEEDS TO BE I #39199901L | Dec 15, 2026 IN VIOLATION | $1,600 |
| Aug 5, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: IMPROPER EXIT/EXIT ACCESS DOORWAY ARRANGEMENT PER BC 1014.2 (2008 CODE); 27-361; BC 1015.2 (2014 CODE); BC 1016.1 (2022 CODE).OBSERVE HOLES PENETRATIONS. L #39155994P | Nov 25, 2025 IN VIOLATION | $625 |
| Apr 30, 2024 | Elevators CLASS - 1 ELECTRICAL BRAKE SWITCHES NOT WORKING IT'S NOT WIRED TO THE CONTROLLER OR BRAKE SWITCHS(CU). EMERGENCY ALARM BELL NO BUZZER. EMERGENCY STOP SWITCH NO BUZZER. #39112995R | Aug 13, 2024 IN VIOLATION | $1,250 |
| Apr 30, 2024 | Elevators CLASS - 1 ELECTRICAL BRAKE SWITCHES NOT WORKING TAMPERED WITH DISABLED(CU). MISSING HIGH HAT LIGHT IN THE CAR DOME OPEN HOLE IN THE CEILING. EMERGENCY ALARM BELL NO BUZZER. EMERGENCY STOP SWITCH NO BUZZER. REMOVE GARBAGE #39112996Z | Aug 13, 2024 IN VIOLATION | $1,250 |
| Oct 9, 2019 | Site Safety CLASS - 1 FAILUER TO HAVE CONSTRUCTION SUPERINTENDENT PRESENT OR DUTIES OF SITE DURING CONSTRUCTION.NOTE:AT TIME OF MY INSPECTOIN OF A 8 STORY BUILDING,ROOF LEVEL UNDER CONSTRUCTION WORK IN PROGRESS UPON REQUEST FOR CONS #35424184K | Jun 2, 2020 IN VIOLATION | $10,000 |
| Apr 24, 2019 | Site Safety CLASS - 1 FAILURE TO DESIGNATE COMPETENT PERSON ON SITE: @TIME OF INSPECTION, I OBSERVED WORKERS ON 4TH FLOOR & REAR YARD @EXP#3:THE SECURITY INFORMEDME, THE SUPER NOR COMPETENT PERSON WAS PRESENT ON SITE.SITE IS ACTIVE #35405410X | Dec 3, 2019 IN VIOLATION | $10,000 |
| Issued | Violation | Status |
|---|---|---|
| Feb 22, 2024 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 #01132 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #04079 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Feb 22, 2024 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 10, 2026 | ECB | Construction: ATOI OBSERVED IN THE ROOM MECHANICAL ROOM A WATER HEATER WAS INSTALLED BEHIND ANOTHER AND BOXED IN WITH NO ROOM OR ACCESS FOR REPAIR/REPLACEMENT/SERVICE. ALSO PVC ON BOILER EXHAUST. CONTRARY TO MC 306 - ACCESS | Open |
| Aug 10, 2026 | ECB | Construction: ATOI OBSERVED THROUGH OUT THE BUILDING OBSTRUCTED SPRINKLER HEADS AND MISSING SPRINKLER CAPS ALL SPRINKLER HEADS MUST BE FREE OF OBSTRUCTIONS CONTRARY TO BC 903.3 - INSTALLATION REQUIREMENTS FOR AUTOMATIC SPRIN | Closed |
| Aug 10, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE -COMPLIANT MANNER. ATOI I OBSERVED AT EXPOSURE#4 THE WALL FACADE IS IN DISREPAIR FROM THE GROUND LEVEL UP TO THIS 4TH FLOOR LEVEL, LOOSE BRICK WITH MISSING MORTAR AN THE CHI | Open |
| Aug 10, 2026 | ECB | Construction: ATOI OBSERVED THROUGH OUT STAIRCASE B ON THE FIRE SPRINKLER HOSE CONNECTION HAS THE USE OF PLASTIC CAPS ALL CAPS MUST BE METAL NO PLASTIC, REPAIR AND/OR REPLACE | Closed |
| Aug 10, 2026 | ECB | Unknown: FAILURE TO PROVIDE/MAINTAIN SUFFICIENT ACCESS/WORK SPACE ABOUT ELECTRICAL EQUIPMENT. OBSERVED IN THE BASEMENT IN THE ATS RM EXCESSIVE STORAGE OF BUILDING MATERIALS AND CONSTRUCTION MATERIALS LADDERS, BUCKETS, T | Closed |
| Aug 10, 2026 | ECB | Elevators: CLASS 1 C/U: 1. ROPE GRIPPER DISABLED BY A SET SCREW, PREVENTING PROPER EMERGENCY FUNCTION. AS PER ASME A17.1 2.19. REMEDY FOR CLASS 1: CORRECT ALL CONDITIONS. LOAD TEST REQUIRED TO LIFT THE C/U ORDER. REINSPEC | Closed |
| Aug 10, 2026 | ECB | Unknown: UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN STAIRWAY B THE SMOKE PURGE IS HANGING FROM CEILING THE LOUVERS ARE BROKEN NEEDS TO BE I | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 11, 2026, 5:37 PM ET. BBL 4101010027.