Queens · Block 2075 · Lot 7501 · 11374

92-28 Queens Boulevard

16 floors · 112 apartments · 145,038 sq ft · built 1987 · class RM · owner of record: Unavailable Owner

73open violations
$0ECB/OATH penalties owed
4HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 68 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 68 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 84 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $12,900 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 120 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 145,038 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 189 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 189 days
Annual filing
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2075). Agency page

Dec 31, 2035
in 3355 days
Next due 2035
Annual boiler inspection (3 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-11 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (3)
IssuedViolationHearingBalance
Jun 12, 2023Boilers CLASS - 2
PIPING ON BOILER LEAKING,NO STORAGE IN BOILER ROOM, FRESH AIR LOUVER NEEDS TO BE CLEANED OUT CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION
#39088280X
Aug 22, 2023
DEFAULT
$0
Jun 12, 2023Boilers CLASS - 2
PIPING ON BOILER LEAKING, DISCHARGE ON RELIEF VALVE MISSING CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION
#39088279Z
Jan 16, 2024
IN VIOLATION
$0
Mar 29, 1996HPD Hazardous
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARMTENT RECORDS. CELLAR CHANGED FROM STORAGE AND ORDINARY USE TO AN APARTMENT. PARTITIONS ERECTED AND KITCHEN AND BATH FACILITIE
#34128030P
Aug 27, 1996
WRITTEN OFF
$0
DOB (2)
IssuedViolationStatus
Oct 11, 2017ELEVATOR

#9028/615686
DOB VIOLATION - ACTIVE
Feb 16, 2017FACADE SAFETY PROGRAM

#HAZ86561
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Feb 16, 2017Facades FISP
CYCLE 8A UNSAFE REPORT FILED
Active
HPD (62) · C 4 · B 48 · A 10
IssuedClassViolationCorrect by
Feb 5, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT DOOR AT COMPACTOR CLOSET, 16th STORYMar 12, 2026
Nov 1, 2021AApt 17C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL AND WEST WALL. IN THE BATHROOM LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHFeb 4, 2022
Oct 18, 2021CApt 17C · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT APARTMENT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHNov 13, 2021
Oct 18, 2021BApt 17C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHNov 22, 2021
Oct 16, 2018AApt 17C · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT WINDOW HEADER IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHJan 19, 2019
Oct 15, 2018A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYJan 18, 2019
Oct 15, 2018BApt 17C · § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHNov 19, 2018
Oct 15, 2018BApt 17C · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHNov 19, 2018
Oct 15, 2018A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYJan 18, 2019
Oct 15, 2018A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING AT PUBLIC HALL, 1st STORYJan 18, 2019
Sep 21, 2015BApt 17C · SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 4th ROOM FROM EAST LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHOct 26, 2015
Sep 21, 2015BApt 17C · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 17C, 15th STORY, 1st APARTMENT FROM EAST AT SOUTHOct 26, 2015
Sep 21, 2015BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE 4th ROOM FROM EAST LOCATED AT APT 17C, 15th STORY, 1st APARTMENT FROM EAST AT SOUTHOct 26, 2015
Sep 21, 2015BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 17C, 15th STORY, 1st APARTMENT FROM EAST AT SOUTHOct 26, 2015
Sep 21, 2015BApt 17C · SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHOct 26, 2015
Jun 29, 2015BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING. IN THE BATHROOM LOCATED AT APT 17C, 16th STORYAug 3, 2015
Jun 29, 2015BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING. IN THE 1st LIVING ROOM FROM NORTH LOCATED AT APT 17C, 16th STORYAug 3, 2015
Jun 29, 2015BApt 17C · SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE SOUTH BED ROOM. LOCATED AT APT 17C, 16th STORYAug 3, 2015
Jun 29, 2015BApt 17C · SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK WALLS AND CEILING. IN THE BATHROOM LOCATED AT APT 17C, 16th STORYAug 3, 2015
Jun 1, 2015BApt 17C · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT PLASTER CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHJul 6, 2015
Jun 1, 2015CApt 17C · SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING IN THE BATHROOM LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHJun 9, 2015
Jun 1, 2015BApt 17C · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT PLASTER CEILING IN THE BATHROOM LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHJul 6, 2015
Jun 1, 2015BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST AND WEST WALLS IN THE BATHROOM LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHJul 6, 2015
Jun 1, 2015BApt 17C · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHJul 6, 2015
Jun 1, 2015BApt 17C · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHJul 6, 2015
Apr 20, 2015ASECTION 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT LOBBYJul 24, 2015
Apr 20, 2015ASECTION 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT LOBBYJul 24, 2015
Apr 20, 2015ASECTION 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCY?S HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT LOBBYJul 24, 2015
Apr 20, 2015BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING. IN THE BATHROOM LOCATED AT APT 17C, 16th STORY, APARTMENT AT EASTMay 25, 2015
Apr 20, 2015BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CRACK WALLS AND CEILING IN THE 1st LIVING ROOM FROM NORTH LOCATED AT APT 17C, 16th STORY, APARTMENT AT EASTMay 25, 2015
Apr 20, 2015ASECTION 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX AT LOBBYJul 24, 2015
Apr 20, 2015BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING IN THE SOUTH BED ROOM LOCATED AT APT 17C, 16th STORY, APARTMENT AT EASTMay 25, 2015
Apr 20, 2015BApt 17C · SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK WALLS AND CEILING IN THE SOUTH BEDROOM. LOCATED AT APT 17C, 16th STORY, APARTMENT AT EASTMay 25, 2015
Apr 20, 2015ASECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING. AT LOBBYJul 24, 2015
Aug 6, 2014BApt 17C · SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHSep 10, 2014
Aug 6, 2014BApt 17C · SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING IN THE BATHROOM LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHSep 10, 2014
Aug 6, 2014BApt 17C · SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 17C, 15th STORYSep 10, 2014
Aug 6, 2014BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH AND WEST WALLS IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHSep 10, 2014
Aug 6, 2014BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST AND WEST WALLS IN THE BATHROOM LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHSep 10, 2014
May 2, 2011BApt 17C · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD CABINET, EAST WALL IN THE KITCHEN LOCATED AT APT 17C, 15th STORYJun 6, 2011
May 2, 2011BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST, WEST & SOUTH WALLS IN THE 3rd ROOM FROM EAST LOCATED AT APT 17C, 15th STORYJun 6, 2011
May 2, 2011BApt 17C · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 17C, 15th STORYJun 6, 2011
May 2, 2011BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST & WEST WALLS IN THE BATHROOM LOCATED AT APT 17C, 15th STORYJun 6, 2011
Jun 8, 2009BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING, SOUTH AND EAST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 17C, 16th STORY, 2nd APARTMENT FROM NORTH AT EASTJul 13, 2009
Jun 8, 2009BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE BATHROOM LOCATED AT APT 17C, 16th STORY, 2nd APARTMENT FROM NORTH AT EASTJul 13, 2009
Jun 8, 2009BApt 17C · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONSEALED WATER LEAK AT NORTH WALL IN THE BATHROOM LOCATED AT APT 17C, 16th STORY, 2nd APARTMENT FROM NORTH AT EASTJul 13, 2009
Jun 8, 2009BApt 17C · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK CEILING INSIDE WALL CABINETS IN THE KITCHEN LOCATED AT APT 17C, 16th STORY, 2nd APARTMENT FROM NORTH AT EASTJul 13, 2009
Jun 8, 2009BApt 17C · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 17C, 16th STORY, 2nd APARTMENT FROM NORTH AT EASTJul 13, 2009
May 11, 2009BApt 17C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WEST WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHJun 15, 2009
May 11, 2009CApt 17C · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK AT CEILING IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHMay 17, 2009
May 11, 2009BApt 17C · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHJun 15, 2009
May 11, 2009BApt 17C · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 17C, 15th STORY, 2nd APARTMENT FROM EAST AT SOUTHJun 15, 2009
May 4, 2007BSECTION 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION WALLS ERECTED AT CELLAR CREATING APT IN CELLAR.Sep 30, 2007
May 4, 2007BApt 16B · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL AND CEILINGS OF ALL ROOMS IN THE ENTIRE APARTMENT LOCATED AT APT 16B, 15th STORYSep 30, 2007
May 4, 2007BApt 16B · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 16B, 15th STORYSep 30, 2007
May 4, 2007BApt 16B · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK CEILING IN THE BATHROOM LOCATED AT APT 16B, 15th STORYSep 30, 2007
May 4, 2007BSECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DRAWERS 16 STY NORTHWEST APT MARKED 18G KITCHEN CABINETS.Sep 30, 2007
May 4, 2007BSECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE STOVE BURNERS 16 STY NORTHWEST APT MARKED 18 G KITCHEN.Sep 30, 2007
May 4, 2007BSECTION 27-2070 ADM CODE DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE, CELLAR.Sep 30, 2007
May 4, 2007BSECTION 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS CELLAR.Sep 30, 2007

Showing 60 of 62. Full list on the agency site.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 24, 2026, 6:44 PM ET. BBL 4020757501.