Bronx · Block 2677 · Lot 70 · 10459

919 Prospect Avenue

6 floors · 37 apartments · 57,600 sq ft · built 1907 · class D7 · owner of record: 919 Prospect Avenue Llc

153open violations
$128,709ECB/OATH penalties owed
34HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 57,600 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Energy audit and retro-commissioning (2027) Likely applies
Local Law 87 · Calendar year 2027
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2677). Agency page

Dec 31, 2027
in 431 days
Next due 2027
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 797 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-20 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (30) · $128,709 owed
IssuedViolationHearingBalance
Jul 21, 2026Elevators CLASS - 1
CLASS 1 (CU):FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER PASSENGER ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, DOOR ZONE RESTRICTOR ON ELEVATOR INOPERATIVE.REPAIR THE DEVICE AND CONT
#39197002Z
Apr 23, 2027
PENDING
$1,250
Mar 17, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. NOTE: AT TIME OF INSPECTION. I OBSERVED HEAVY CORRODED STEEL LINTEL, STEEL ANCHOR OF FIRE ESCAPE, DAMAGED STONE MASONRY DECOR, DISLODGED STONE DECOR, SPALLIN
#35726419J
Mar 18, 2027
PENDING
$5,000
Mar 17, 2026Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE: AT TIME OF INSPECTION, I OBSERVED AIR CONDITIONER, FLOWER, POTS, HOUSEHOLD STUFFS BLOCKING SHORTSIDE OF FIRE ESCAPE OF LANDING DECKS. MULTI-LOCATIONS AT EX
#35726418H
Mar 18, 2027
$2,500
Apr 11, 2024Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #919155. REMEDY: SUBMIT ACCEPTABLE REQU
#37027935X
May 4, 2027
PENDING
$1,280
Feb 1, 2024Construction CLASS - 2
AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED ERECTED WITH LIGHTS NOT ON UPON SEARCH IN DOB NOW AND BIS SYSTEMS BOTH REVEALED NO PERMITS ON RECORD AS REQUIRED TO HAVE.PROPERLY OBTAIN AND MAINTAIN VALID PERMITS
#39525265K
Mar 21, 2025
IN VIOLATION
$3,125
Feb 1, 2024Construction CLASS - 2
AT TIME OF INSPECTION 5:55 AM I OBSERVED SIDEWALK SHED ERECTED WITH LIGHT FIXTURES PRESENT BUT NOT ON CREATING A HAZARDOUS CONDITION FOR PEDESTRIANS WALKING ON SIDEWALK FROM MUGGINGS, ASSAULTS AND OTHER HEINOUS
#39525264Z
Mar 21, 2025
IN VIOLATION
$6,000
Feb 1, 2024Construction CLASS - 2
AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED ERECTED WITH MISSING CONTACT INFORMATION PANEL WITH NAME AND NUMBER TO CALL IN CASE OF EMERGENCY.PROPERLY MAINTAIN CONTACT INFORMATION PANEL AS REQUIRED
#39525266M
Mar 21, 2025
IN VIOLATION
$1,250
Nov 21, 2023Construction CLASS - 2
AT 5:30AM OBSERVED 6 STORY BUILDING WITH SWS AT EXP 1 AND 2 THAT WAS NOT ILLUMINATED AS STIPULATED IN BC3307.6.4.8 CREATES HAZARDOUS CONDITIONS FOR PEDESTRIANS OF SLIPS AND TRIPS DUE TO INADEQUATE LIGHTING IN D
#39523554H
Jun 3, 2024
IN VIOLATION
$2,400
Nov 21, 2023Construction CLASS - 2
OBSERVED 6 STORY RESIDENTIAL BUILDING WITH SWS EXP 1 AND 2 WITH LIGHTING NOT MAINTAINED PER BC3307.6.4.8, REVIEWED OF BIS AND DOBNOW REVEALED NO ACTIVE SWS PERMITS FOR TEMPORARY CONSTRUCTION EQUIPMENT ON SITE.R
#39523555J
Jun 3, 2024
IN VIOLATION
$1,250
Oct 3, 2023Construction CLASS - 1
SUMMONS ISSUED FOR FAILURE TO MAINTAIN DUE TO MULTIPLE CRACKS AND MISSING MORTAR JOINTS ON EXPOSURE #4 EXTERIOR BRICK FACADE ALONG WITH INTERIOR WALL AT 5TH FLOOR LEVEL HAVING MINOR WATER DAMAGE., REPAIR AND/RE
#39096354J
Jan 12, 2024
IN VIOLATION
$1,250
Aug 17, 2023Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS FACADES AND APPURTENANCES. OBSERVED CRACKED STONE WORK IN MULTIPLE LOCATIONS ON EXPOSURES 1 AND 2 AND DEFECTIVE RAILING AT PARAPET LEVEL. REMEDY: MAINTAIN BUILDING EX
#35674505Y
Dec 31, 2026
DEFAULT
$6,250
May 30, 2023Construction CLASS - 1
UNLAWFUL ACTS.FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.NOTE:RESPONDENT FAILURE TO COMPLY WITH PREVIOUS ECB VIOLATION#35670236R DATED 04/06/2023,35670237Z DATED 04/06/2022 AND 35669349P DATED 11/22/2022 AND 3
#35674261R
Mar 1, 2027
$6,280
May 13, 2023Elevators CLASS - 2
CLASS 2: PHONE INOPERATIVE REPPAIR & PROGRAM TO 24 HR EMERGENCY OPERATOR. EMERGENCY LIGHT INOPERATIVE CHECK WIRES & REPAIR.
#39086223K
Nov 7, 2024
DEFAULT
$1,562
Apr 21, 2023Elevators CLASS - 2
CLASS 2: PHONE INOPERATIVE REPAIR & PROGRAM TO 24 HR EMERGENCY OPERATOR. EVACUATION SIGNS MISSING. PROVIDE AT EVERY FLOOR STOP. CERTIFICATE FRAME/INSPECTION CARD MISSING. PROVIDE FRAME & CARD. CAR FLOOR NOT LEV
#39084356P
Aug 14, 2026
IN VIOLATION
$625
Apr 6, 2023Construction CLASS - 1
FAILURE TO PROVIDE SIDEWALK SHED WHERE REQUIRED.OBSERVED UNPROTECTED/UNSECURED (NO SIDEWALK SHED)AT NORTH WEST CORNER OF EXPOSURE#1 NORTH ELEVATION (PARTIAL SHED IN PLACE).ALSO SOUTH EAST CORNER OF EXPOSURE#2 E
#35670237Z
Apr 13, 2026
IN VIOLATION
$10,000
Apr 6, 2023Construction CLASS - 1
UNLAWFUL ACTS.FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.NOTE:PREVIOUS ECB VIOLATIONS#35669349P DATED 11/22/2022 AND #35670373N DATED 02/08/2023 REQUIRED OWNER TO MAINTAIN BUILDING EXTERIOR WALLS AND PROVIDE S
#35670236R
Jan 19, 2027
$12,500
Feb 8, 2023Construction CLASS - 1
UNLAWFUL ACTS,FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.NOTE:ECB VIOLATION #35669349P DATED 11/22/22 REQUIRED OWNER TO MAINTAIN EXTERIOR BUILDING WALLS & PROVIDE SAFETY MEASURES.NOTED:ECB VIOLATION #35669550R
#35670373N
Apr 22, 2027
DEFAULT
$6,250
Feb 8, 2023Construction CLASS - 1
FAILURE TO PROVIDE SIDEWALK SHED WHERE REQUIRED.NOTE:AS PER TODAY'S INSPECTION UNPROTECTED/UNSECURED(NO SWS) AT NORTH/WEST CORNER OF EXP #1 NORTH ELEVATION(PARTIAL SHED IN PLACE)& SOUTH/EAST CORNER OF EXP #2 EA
#35670372L
Nov 20, 2026
DEFAULT
$12,500
Nov 22, 2022Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTE AT THE TIME OF INSPECTION,OBSERVED FIRE ESCAPE ARE BLOCKING AT EXP4 WEST ELEVATION ON FIFTH FLOOR LEVEL.REMEDY:REMOVE EGRESS OBSTRUCTION.
#35669550R
Dec 31, 2026
DEFAULT
$3,125
Nov 22, 2022Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES.NOTE AT THE TIME OF INSPECTION,OBSERVED ALL EXPOSURES 1,2,3,AND 4 DEFECTIVE CONDITION ATMULTIPLE LOCATIONS.ALSO EXP1 AND 2 BOTH CORNER AT ROOF RAILING MISSING
#35669349P
Dec 31, 2026
DEFAULT
$12,500
Nov 14, 2022Construction CLASS - 1
A SECTION OF DECORATIVE STONE FROM AROUND THE 4TH FLOOR FIRE-ESCAPE FELL TO THE SIDEWALK. OTHER SECTION OF THE FACADE IS CRACKED VARIOUS LOCATION. EXPOSURE 1 AND 4., MAINTAIN EXTERIOR BUILDING WALL
#39073852K
Dec 31, 2026
DEFAULT
$25,000
Mar 15, 2022Boilers CLASS - 2
FOUND BEST BOILER MODEL #5B-100, NOT OPERABLE, HOLES ON CEILING AND WALLS, BOILER DOORS NEED TO BE RESEALED, SIGHT GLASS MISSING ON REAR CHAMBER DOOR.
#39058074H
Dec 31, 2026
DEFAULT
$1,562
Oct 7, 2020Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER - AT REAR OF PREMISES - STAIRS LEADING TO BASEMENT LOOSE NOT STRUCTURALLY INSTALLED/SUPPORTED&STATE OF DISREPAIR-UNSAFE TO USE. REMEDY:REPAIR AND/OR REPLACE
#35496763H
Jul 23, 2021
IN VIOLATION
$1,250
Jan 2, 2020Unknown CLASS - 2
UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE. LOBBY NEWLY INSTALLED FLUORESCENTLIGHTS:LIGHTING FIXTURES ARE NOT INSTALLED PROPERLY,NO BOXES PROVIDED
#35360052Z
Dec 31, 2026
DEFAULT
$4,000
Aug 31, 2018Boilers CLASS - 2
50A,50B,50C,50D,50E,50F-AS PER CLASS (B254) 28-301.1 FAILURE TO MAINTAIN. 50A)HOLES IN BOILER ROOM CEILING AND WALLS. 50B)HOT & COLD WATER PIPING LEFT UNCAPPED. 50C)DOGLEGS MISSING AT FRONT & REAR BOILER ACCESS
#32097752P
Oct 19, 2018
STIPULATION/IN-VIO
$0
May 4, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. AT THE TIME OF INSPECTION,I OBSERVED AT BOILER ROOM METERS AREA CEILING IN DISREPAIR & IN DANGER OF COLLAPSING APPROX 15SQ FT AREA. CEILING IS BEING SHORING UP
#35322816M
Jun 29, 2018
IN VIOLATION
$0
Sep 29, 2015Unknown CLASS - 2
UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE.THE ENTIRE 2D:DEFECTIVE WIRING ARE IN USE,DEFECTIVE LIGHTS ARE IN USE,DEFECTIVE RECEPTACLES ARE IN USE,
#35159260Z
Nov 20, 2015
STIPULATION/IN-VIO
$0
Jan 14, 2010Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR OF BUILDING. DEFECT: THROUGHOUT EXTERIOR FACADE,KEYSTONES & DECORATIVE STONES ABOVE WINDOWS ARE DISLODGED,SPALLING & HAVE MORTAR MISSING. THE CONCRETE WINDOWS SILLS ARE ALSO CRACKED
#34812020M
Mar 5, 2010
IN VIOLATION
$0
Aug 1, 2007Boilers Non-Hazardous
B4A-50.BEST FTSM BOILER LP STON,SN 2190 HP 500 SQ FT,OIL 2003.50-NO MANUAL TEST LEVER INSTALLED ON TEH SAFETY VALVE.INSTALL TEST LEVER FOR CODE COMPLIANCE.
#32052101M
Sep 21, 2007
IN VIOLATION
$0
Jan 24, 2007Boilers Non-Hazardous
B4B,51,50A,B,C,D,3B,48B.50A-BOILER UPPER CASING CORRODED & COMBUSTION LEAKING.50B-EXHAUST GAS BACKING THROUGH THE DRAFT STAT.50C-CLEAN OUT DOOR MISSING ON FLUE PIPE.50D-NEED SUPPORT ON FLUE PIPE
#32053128R
Jul 20, 2007
IN VIOLATION
$0
DOB (35)
IssuedViolationStatus
Jun 30, 2026CONSTRUCTION
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER: DOB VIOLATION #031726CLL2 0301YC REQUIRED THE IMMEDIATE 100% HANDS ON INSPECTION OF ALL FACADES BY A PE/RA & SUBMIT A REPORT TO FACADE VIA EMAIL BY 3/25/26. AS OF 06/30/2026, NO HAND ON INSPECTION REPORT SUBMITTED TO FACADE UNIT REMEDY: COMPLY WITH DOB VI
#LL20315CM
DOB VIOLATION - ACTIVE
Mar 17, 2026CONSTRUCTION
FTM FACADE & APPURTANCES. LARGE SECTION OF FIRE ESCAPE STONE ENCASEMEN DISLODGING & FALLING ON TO SIDEWALK SHED BELOW. EXP2 E ELEV & SPALLING LOOSE BRICKS W/DEEP OPEN MORTAR JOINTS/PARAPET. REMEDY:OWNER TO IMMEDI RETAIN SVCS OF NYS RDP W/QEWI CERT TO INSPECT & EVALUATE 100% MASONRY FACADE, PARAP &FI
#LL20301YC
DOB VIOLATION - ACTIVE
Oct 2, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00051
DOB VIOLATION - ACTIVE
Aug 2, 2024FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00226
DOB VIOLATION - ACTIVE
Jun 23, 2024FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023)
#00758
DOB VIOLATION - ACTIVE
Jun 19, 2024CONSTRUCTION
STRUCTURE RENDERED NON COMPLIANT, AT TIME OF INSPECTION DAMAGE OBSERVED TO HAVE BEEN SUSTAINED TO SIDEWALK SHED DUE TO MOTOR VEHICLE JUMPING THE CURB AND IMPACTING UPRIGHTS OF SIDEWALK SHED.
#24-01617
DOB VIOLATION - ACTIVE
May 2, 2024FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00448
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01061
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01065
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#28308
DOB VIOLATION - ACTIVE
May 30, 2023CONSTRUCTION
EMERGENCY WORK ORDER TO PROVIDE SAFETY MEASURES.NOTE:TAKE&PROVIDE ADEQUATE SAFETYMEASURES (SIDEWALK SHED)TO SECURE PUBLIC SAFETY @EXP#1 N.ELEV&EXPO#2E.ELEV.INADEQ.SAFETY MEASURES IN PL.EXP#4.W.ELEV STEP CRACK SEPERATING MASONRY ON TOP LEVEL OF CHIMNEY,SPALLING DAMAGED MORTAR JOINT@SEVERALLOC.REMEDY:
#FA20301MK
DOB VIOLATION - ACTIVE
Apr 22, 2023FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2022)
#00373
DOB VIOLATION - ACTIVE
Feb 22, 2023NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
#00477
DOB VIOLATION - ACTIVE
Aug 21, 2022FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2021)
#00605
DOB VIOLATION - ACTIVE
Nov 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00267
DOB VIOLATION - ACTIVE
Aug 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00391
DOB VIOLATION - ACTIVE
Jun 22, 2021ELEVATOR

#9028/704224
DOB VIOLATION - ACTIVE
Jun 20, 2021FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2020)
#00478
DOB VIOLATION - ACTIVE
Jun 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00619
DOB VIOLATION - ACTIVE
Apr 29, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2001880
DOB VIOLATION - ACTIVE
Feb 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00209
DOB VIOLATION - ACTIVE
Nov 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00278
DOB VIOLATION - ACTIVE
Aug 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00536
DOB VIOLATION - ACTIVE
Jun 29, 2020FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2019)
#00366
DOB VIOLATION - ACTIVE
May 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00536
DOB VIOLATION - ACTIVE
Mar 18, 2019FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2018
#10016
DOB VIOLATION - ACTIVE
Feb 24, 2017LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
#03837
DOB VIOLATION - ACTIVE
Oct 1, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
#03622
DOB VIOLATION - ACTIVE
Mar 3, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
#04882
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#07438
DOB VIOLATION - ACTIVE
Dec 31, 2009LOW PRESSURE BOILER

#06710
DOB VIOLATION - ACTIVE
Feb 13, 2004LOCAL LAW 62/91 - BOILERS

#08191
DOB VIOLATION - ACTIVE
Mar 19, 2003LOCAL LAW 62/91 - BOILERS

#09258
DOB VIOLATION - ACTIVE
Mar 26, 2002LOCAL LAW 62/91 - BOILERS

#10148
DOB VIOLATION - ACTIVE
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#02031
DOB VIOLATION - ACTIVE
DOB NOW Safety (42)
IssuedViolationStatus
Sep 25, 2026Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Aug 31, 2026AEUHAZ FTC-AEU-HAZ
Active
Jun 22, 2026Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
May 15, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 6, 2026Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Dec 3, 2025Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Sep 26, 2025Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Feb 28, 2025Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Dec 2, 2024Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Oct 2, 2024AEUHAZ FTC-AEU-HAZ
Active
Aug 2, 2024Benchmarking - LL84 FTF-EN-BENCH
Active
Jun 23, 2024Retro-Commissioning - LL87 FTF-EN-EARCX
Active
May 2, 2024Benchmarking - LL84 FTF-EN-BENCH
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Apr 22, 2023Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Feb 22, 2023Facades FISPNRF
CYCLE 9B NO REPORT FILED
Active
Aug 21, 2022Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Nov 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Jun 20, 2021Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Jun 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Apr 29, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Feb 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Nov 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Jun 29, 2020Retro-Commissioning - LL87 FTF-EN-EARCX
Active
May 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Mar 18, 2019Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Feb 24, 2017Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
Active
Oct 1, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
Active
Mar 3, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
Dec 31, 2009Boiler LBLVIO
Active
Feb 13, 2004Boiler LL6291
Active
Mar 19, 2003Boiler LL6291
Active
Mar 26, 2002Boiler LL6291
Active
HPD (62) · C 34 · B 22 · A 5
IssuedClassViolationCorrect by
Jan 31, 2024I§27-2153 ADM CODE THE PREMISES HAS BEEN SELECTED TO PARTICIPATE IN THE ALTERNATIVE ENFORCEMENT PROGRAM WHICH MAY RESULT IN BUILDING-WIDE INSPECTIONS, FEES, AND EXTENSIVE REPAIR WORK TO CORRECT VIOLATIONS AND UNDERLYING CONDITIONS. CHARGES FOR REPAIR WORK DONE PURSUANT TO THIS ORDER, IF NOT PAID, WIL—
Sep 29, 2026B§ 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL.Nov 3, 2026
Sep 29, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTISE LOCK AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORYNov 3, 2026
Sep 29, 2026B§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE BLACK GARBAGE BAGS AT BASEMENTNov 3, 2026
Aug 31, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE THE MORTISE LOCK AND STRIKE PLATE AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORYOct 5, 2026
Aug 31, 2026C§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12.Sep 26, 2026
Aug 31, 2026C§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12.Sep 26, 2026
Aug 31, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER AT BUILDING ENTRANCE TO APARTMENTS AT FRONT AREAWAY, 1st STORYOct 5, 2026
Aug 31, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER SYSTEM AT BUILDING ENTRANCE TO ALL APARTMENTS AT FRONT AREAWAY, 1st STORYOct 5, 2026
Aug 31, 2026A§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES BETWEEN ELEVATOR AND STAIR CASE AT PUBLIC HALL, 6th STORYDec 4, 2026
Aug 31, 2026C§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12.Sep 26, 2026
Aug 31, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND EAST WALL BETWENN ELEVATOR AND STAIR WAY AT PUBLIC HALL, 6th STORYOct 5, 2026
Aug 6, 2026CApt 5D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTSep 1, 2026
Jul 16, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL/BUZZER INTERCOM SYSTEM , 1st STORYAug 20, 2026
Apr 20, 2026CApt 1A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WESTMay 16, 2026
Apr 20, 2026CApt 1A · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM NORTH AT EAST WALL IN THE 4th ROOM FROM EAST AT NORTH LOCATED AT AMay 14, 2026
Apr 20, 2026CApt 1A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WESTMay 16, 2026
Apr 20, 2026BApt 1A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT THE EAST WALL IN THE 4th ROOM FROM EAST AT NORTH LOCATED AT APT 1A, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WESTMay 25, 2026
Apr 20, 2026CApt 1A · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE AND EITHER TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 OR TESTED POSITIVE FOR LEAD CONTENT ON A METAL OR CERAMIC SUBSTRATE AS SET FORTH IN (28 RCNY §11-07(b)) USING WORK PRACTICES SMay 14, 2026
Mar 23, 2026C§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING CAST LIME STONE MOLDING APROX. 6FT. X 1FT AT 2nd FIRE ESCAPE FROM NORTH AT EAST, 6th STORYMar 29, 2026
Mar 23, 2026C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE APROX. 6FT. X 1 FT LIME CAST STONE BENEATH BOTTOM FRONT RAIL AT BALCONY AT 2nd FIRE ESCAPE FROM NORTH AT EAST, 5th STORYMar 29, 2026
Mar 23, 2026C§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING CONCRETE PLATFORM AT BALCONY AT 2nd FIRE ESCAPE FROM NORTH AT EAST, 6th STORYMar 29, 2026
Mar 23, 2026C§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING CONCTRETE PLATFORM AT BALCONY AT 1st FIRE ESCAPE FROM NORTH AT EAST, 6th STORYMar 29, 2026
Mar 5, 2026C§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ALL BELL AND RETURN BUZZERS AT FRONT ENTRANCE TO THE BUILDING , 1st STORYMar 11, 2026
Dec 19, 2025BApt 1A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INOPERATIVE BELL AND RETURN BUZZER FROM BUILDING ENTRANCE TO APT # 1C IN THE ENTRANCE LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EASTJan 23, 2026
Dec 19, 2025CApt 1A · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK ON DOOR LEADING TO ROOM WITH FIRE ESCAPE IN THE 4th ROOM FROM EAST LOCATED AT APT 1A, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WESTDec 25, 2025
Oct 22, 2025B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER SYSTEM TO BUILDING AT FRONT AREAWAY, 1st STORYNov 26, 2025
Oct 20, 2025B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INOPERATIVE BELL AND RETURN BUZZER FROM BUILDING ENTRANCE AT PUBLIC HALL, 1st STORYNov 24, 2025
May 2, 2025BApt 4B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJun 6, 2025
May 2, 2025BApt 4B · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE FAUCET IN THE KITCHEN LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJun 6, 2025
Mar 26, 2025BApt 4E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... SOUTH WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHApr 30, 2025
Mar 24, 2025AApt 4B · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SADDLE AT ENTRANCE IN THE BATHROOM LOCATED AT APT 4B, 5th STORY, 1st APARTMENT FROM WEST AT NORTHJun 27, 2025
Mar 24, 2025AApt 4B · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SADDLE AT ENTRANCE IN THE 3rd ROOM FROM EAST LOCATED AT APT 4B, 5th STORY, 1st APARTMENT FROM WEST AT NORTHJun 27, 2025
Mar 24, 2025BApt 4B · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE UPPER HINGE AT DOOR AT SOUTH IN THE 6th ROOM FROM EAST LOCATED AT APT 4B, 5th STORY, 1st APARTMENT FROM WEST AT NORTHApr 28, 2025
Mar 24, 2025AApt 4B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTERTOP AT SINK IN THE KITCHEN LOCATED AT APT 4B, 5th STORY, 1st APARTMENT FROM WEST AT NORTHJun 27, 2025
Mar 24, 2025AApt 4B · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SADDLE AT ENTRANCE IN THE KITCHEN LOCATED AT APT 4B, 5th STORY, 1st APARTMENT FROM WEST AT NORTHJun 27, 2025
Jan 8, 2025BApt 1E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQFT AT EAST WALL, SOUTH WALL, WEST WALL, AND AT CEILING IN THE BATHROOM LOCATED AT APT 1E, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHFeb 12, 2025
Dec 4, 2024CApt 1A · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) WEST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 1A, 2nd STORY, 3rd APARTMENT FROM SDec 28, 2024
Nov 15, 2024CApt 5D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTDec 11, 2024
Nov 15, 2024CApt 5D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTDec 11, 2024
Sep 24, 2024BApt 4E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM FROM THE BUILDING ENTRANCE TO THE NORTH WALL IN THE KITCHEN LOCATED AT APT 4E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTHOct 29, 2024
Jun 11, 2024CApt 4B · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SADDLE AT ENTRANCE IN THE KITCHEN LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJun 17, 2024
Jun 11, 2024CApt 4B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER SASH 2ND WINDOW AT NORTH IN THE 6th ROOM FROM EAST LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJun 17, 2024
Jun 11, 2024CApt 4B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MARBLE SADDLE AT ENTRANCE IN THE BATHROOM LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJun 17, 2024
Feb 27, 2024C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK AND MORTAR JOINTS AT EXTERIOR WALL AT WEST YARD, 6th STORYMar 4, 2024
Feb 27, 2024C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK AND MORTAR JOINTS AT EXTERIOR WALL AT EAST YARD, 6th STORYMar 4, 2024
Mar 31, 2023CApt 4B · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH AApr 24, 2023
Mar 30, 2023CApt 4B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM EAST AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 4B, 5th STORY, 1sApr 23, 2023
Mar 30, 2023CApt 4B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 4B, 5tApr 23, 2023
Mar 30, 2023CApt 4B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) 1stApr 23, 2023
Mar 30, 2023CApt 4B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 5th STORY, 1st APARTMENT FROM WEST AT NORTHApr 25, 2023
Mar 30, 2023CApt 4B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 5th STORY, 1st APARTMENT FROM WEST AT NORTHApr 25, 2023
Mar 30, 2023CApt 4B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM EAST AT SOUTH WALL, 1st WINDOW FRAME FROM WEST AT NORTH WALL IN THApr 23, 2023
Mar 30, 2023CApt 4B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) 1stApr 23, 2023
Mar 30, 2023CApt 4B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM EAST AT SOUTH WALL, 1st WINDOW FRAME FROM WEST AT NORTH WALL IN THApr 23, 2023
Mar 30, 2023CApt 4B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) 1stApr 23, 2023
Jun 1, 2021BApt 4B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM EAST LOCATED AT APT 4B, 5th STORY, 1st APARTMENT FROM WEST AT NORTHJul 6, 2021
Jul 20, 2020CApt 3B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st WINDOW FRAME FROM WEST AT NORTH WALL IN THE KITCHEN LOCATED AT APT 3B, 4th STORY, Aug 13, 2020
Sep 17, 2018BApt 4B · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM WEST AT NORTHOct 22, 2018
Sep 17, 2018BApt 4B · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM WEST AT NORTHOct 22, 2018

Showing 60 of 62. Full list on the agency site.

Issued in the last 120 days

DateSourceWhatNow
Sep 29, 2026HPD B§ 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL.Open
Sep 29, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTISE LOCK AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORYOpen
Sep 29, 2026HPD B§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE BLACK GARBAGE BAGS AT BASEMENTOpen
Sep 25, 2026DOB SafetyBenchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4Open
Aug 31, 2026DOB SafetyAEUHAZ: Open
Aug 31, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE THE MORTISE LOCK AND STRIKE PLATE AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORYOpen
Aug 31, 2026HPD C§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12.Open
Aug 31, 2026HPD C§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12.Closed
Aug 31, 2026HPD C§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12.Open
Aug 31, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER AT BUILDING ENTRANCE TO APARTMENTS AT FRONT AREAWAY, 1st STORYOpen
Aug 31, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER SYSTEM AT BUILDING ENTRANCE TO ALL APARTMENTS AT FRONT AREAWAY, 1st STORYOpen
Aug 31, 2026HPD A§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES BETWEEN ELEVATOR AND STAIR CASE AT PUBLIC HALL, 6th STORYOpen
Aug 31, 2026HPD C§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12.Open
Aug 31, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND EAST WALL BETWENN ELEVATOR AND STAIR WAY AT PUBLIC HALL, 6th STORYOpen
Aug 6, 2026HPD C§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF ILLEGAL ELECTRICAL PANEL INSTALLED WITH EXPOSED WIRES AT EAST EXTERIOR BULKHEAD AT ROOFClosed
Aug 6, 2026HPD C§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTOpen
Jul 21, 2026ECBElevators: CLASS 1 (CU):FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER PASSENGER ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, DOOR ZONE RESTRICTOR ON ELEVATOR INOPERATIVE.REPAIR THE DEVICE AND CONTOpen
Jul 16, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL/BUZZER INTERCOM SYSTEM , 1st STORYOpen
Jun 30, 2026DOBCONSTRUCTION: FAILURE TO COMPLY WITH COMMISSIONER'S ORDER: DOB VIOLATION #031726CLL2 0301YC REQUIRED THE IMMEDIATE 100% HANDS ON INSPECTION OF ALL FACADES BY A PE/RA & SUBMIT A REPORT TO FACADE VIA EMAIL BY 3/25/26. AS OF 06/30/2026, NO HAND ON INSPECTION REPORT SUBMITTED TO FACADE UNIT REMEDY: COMPLY WITH DOB VIOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 6:31 AM ET. BBL 2026770070.

Look up another building