Brooklyn · Block 3150 · Lot 3 · 11206

917 Broadway

6 floors · 8 apartments · 9,733 sq ft · built 1931 · class D7 · owner of record: B 917 Broadway Realty Llc

1open violations
$44,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 70 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 70 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 70 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2022-07-12 (Accepted). Agency page

Dec 31, 2026
in 70 days
2 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 86 days
Annual

Open violations

ECB / OATH (15) · $44,000 owed
IssuedViolationHearingBalance
Nov 2, 2022Construction CLASS - 2
AT TIME OF INSPECTION OF CLASS 1 VIOLATION #39505169M ISSUED ON 08-17-22 OBSERVED JOB SITE CLOSED. UPON RESEARCHING BIS AND DOB NOW NO CERTIFICATE OF CORRECTION WAS FILED. GC FAILED TO COMPLY WITH COMMISSIONER
#39508697J
Oct 10, 2023
IN VIOLATION
$625
Nov 2, 2022Construction CLASS - 2
AT THE TIME OF INSPECTION OF PROPOSED 6 STORY ALTERATION, OBSERVED CLOSED JOB SITE. UPON RESEARCHING ON DOB SYSTEM, CERTIFICATE OF CORRECTION FOR VIOLATION #39504838X WAS NOT FILED. G.C FAILED TO COMPLY WITH C
#39508626M
Sep 26, 2023
IN VIOLATION
$625
Aug 9, 2022Construction CLASS - 2
ON 6 STORY ALT1 SITE COLLAPSED FACADE AT REAR OBSERVE NO PROJECT INFORMATION SIGN POSTED AT FRONT PER CODE BC 3301.9, 3301.9.1.1 TO 3301.9.1.4POST PROJECT INFORMATION SIGN TO CODES IN VIOLATION DETAILS
#39504839H
May 12, 2023
IN VIOLATION
$625
Aug 9, 2022Construction CLASS - 1
FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO GUARD RAILS. AT TIME OF INSPECTION OBSERVED AT INTERIOR OPENINGS AT STAIRS NO GUARD RAILS ALONG WITH EXPOSURE #3 AT ALL LEVEL
#39067664M
Mar 29, 2024
IN VIOLATION
$2,500
Aug 9, 2022Construction CLASS - 1
FAILURE TO PROVIDE JOB FENCE BC 3307.7 TO 3307.7.1. ON 6 STORY ALT1 SITE FACADE COLLAPSED AT REAR OBSERVED COLLAPSED FACADE DEBRIS/STRUCTURE ON EXPOSURE#4 ADJACENT PROPERTY REAR YARD (921 BROADWAY) AND NO JOB F
#39504840P
May 12, 2023
IN VIOLATION
$500
Aug 9, 2022Construction CLASS - 1
ON 6 STORY ALT1 SITE DEMOLISHED INTERIOR+ROOF AND FACADE COLLAPSED AT REAR OBSERVE EXISTING STAIRS FROM CELLAR TO 3RD FLOOR LEVEL MISSING STAIR HANDRAILS TO CODE BC3301.2+1009.12 AND BC3301.1+OSHA 1910.29(F)-19
#39504835K
May 12, 2023
IN VIOLATION
$1,000
Aug 9, 2022Construction CLASS - 1
FAILURE TO COMPLY WITH FDNY CODE FOR FIRE EXTINGUISHER. ON 6 STORY ALT1 SITE FACADE COLLAPSED AT REAR OBSERVE EXISTING 3 STORY LUMBER STRUCTURE AND NO 2A20BC FIRE EXTINGUISHER TO CODE BC 3303.7.2+FC 906.3 AT EV
#39504836M
May 12, 2023
IN VIOLATION
$625
Aug 9, 2022Construction CLASS - 1
FAILURE TO SECURE OPENINGS/PENETRATIONS. AT TIME OF INSPECTION OBSERVED MULTIPLE OPENINGS APPROXIMATELY 3'X3' AT ALL LEVELS LEFT UNSECURED & UNPROTECTED FROM TRIPS 7 FALLS. (BC 3301.2); 3301.2, COMPLY WITH CODE
#39067662Z
Mar 29, 2024
IN VIOLATION
$2,500
Aug 9, 2022Construction CLASS - 1
FAILURE TO SAFE GUARD ALL PERSONS & PROPERTY. AT TIME OF INSPECTION NO OVERHEAD PROTECTION FOR ADJOINING PROPERTY'S DURING DEMOLITION WHERE WALL HAS COLLAPSED ALSO NO PROTECTION AT EXPO#1 CONSTRUCTION DEBRIS HA
#39067663K
Mar 29, 2024
IN VIOLATION
$10,000
Aug 9, 2022Construction CLASS - 1
FAILURE TO WEATHERPROOF ADJOINING PROPERTY BC 3309.9.ON 6 STORY ALT1 SITE FACADE COLLAPSED AT REAR I OBSERVE SITE INTERIOR AND ROOF DEMOLISHED EXPOSING EXPOSURE#2 PROPERTY 915 BROADWAY WALL AND ROOF OPEN TO ELE
#39504834Z
May 12, 2023
IN VIOLATION
$2,500
Aug 9, 2022Construction CLASS - 1
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. AT TIME OF INSPECTION PREMISES UNDER ALT1 # 321596607 VERTICAL ENLARGEMENT, OBSERVED ENTIRE EXPOSURE #3 EXTERIOR WALL HAS BEE
#39067660P
Mar 29, 2024
IN VIOLATION
$2,500
Aug 9, 2022Construction CLASS - 1
FAILURE TO MAINTAIN ELEMENTS IN EXISTING BUILDINGS, FIRE ESCAPE BC 3303.9. ON 6 STORY ALT1 SITE FACADE COLLAPSED AT REAR OBSERVE FIRE ESCAPE NOT IN PLACE FOR THE EXISTING 3 STORY SECTION OF THE BUILDING NOT TO
#39504838X
May 12, 2023
IN VIOLATION
$2,500
Aug 9, 2022Unknown CLASS - 1
FAILURE TO MAINTAIN RECORD OF PRE-SHIFT SAFETY MEETING FOR EACH WORKER. AT TIME OF INSPECTION OBSERVED ONGOING WORK HAS BEEN PERFORMED WITH APPROXIMATELY 10 WORKERS REMOVING CONSTRUCTION DEBRIS, REQUESTED PRE-S
#39067658X
Mar 29, 2024
IN VIOLATION
$2,500
Aug 9, 2022Construction CLASS - 1
ON 6 STORY (60FT) ALT1 SITE FACADE COLLAPSED AT REAR OBSERVED 3 STORY EXISTING STRUCTURE ROOF DEMOLISHED (30FT ABOVE GROUND LEVEL) AND NO SIDEWALK SHED IN PLACE TO CODE BC 3307.6.2(2) AND 3307.6.2(4)+EXCEPTIONS
#39504841R
May 12, 2023
IN VIOLATION
$10,000
Aug 9, 2022Construction CLASS - 1
FAILURE TO NOTIFY THE DEPARTMENT OF AN ACCIDENT. AT TIME OF INSP (REQUESTED BY FDNY) OBSERVED EXPO #3 EXTERIOR WALL COLLAPSED. INCIDENT TOOK PLACE ON 08/08/2022 AS PER NEIGHBORING TENANT & WHERE CONSTRUCTION SI
#39067659H
Mar 29, 2024
IN VIOLATION
$5,000
DOB (1)
IssuedViolationStatus
Feb 7, 2001CONSTRUCTION
HAZARDOUS
#04JL01
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 21, 2026, 10:14 AM ET. BBL 3031500003.