Brooklyn · Block 2085 · Lot 15 · 11201

91 Dekalb Avenue

30 floors · 324 apartments · 343,710 sq ft · built 2023 · class D6 · owner of record: Long Island University

0open violations
$33,125ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 118 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 343,710 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1162 days
Next cycle year 2029
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2085). Agency page

Dec 31, 2035
in 3353 days
Next due 2035

Open violations

ECB / OATH (4) · $33,125 owed
IssuedViolationHearingBalance
Feb 10, 2025Unknown CLASS - 2
UPON CHECKING DEPARTMENT RECORDS. I OBSERVED THE SWS PERMIT EXPIRED. COMPLY WITH CODE. MAINTAIN AT ALL TIMES AN ACTIVE PERMIT.
#39536783Y
Apr 16, 2025
DEFAULT
$3,125
Jul 16, 2024Unknown CLASS - 2
RESPONDENT FAILED TO CORRECT THE VIOLATING CONDITION AND FILE FOR A CERTIFICATE OF CORRECTION PURSUANT TO AC 28-204.2 FOR VIOLATION NO. 39528808L ISSUED DATED 05/21/2024. AT TIME OF INSPECTION, JOBSITE FOUND AC
#39530557Z
Sep 25, 2024
DEFAULT
$5,000
May 21, 2024Unknown CLASS - 1
DURING FOLLOW-UP INSPECTION RELATED TO INCIDENT 43275 WHERE WORKER FELL OFF FROM ROOF TO THE TERRACE INSPECTION REVEALED: CONTRACTOR FAILURE TO INSTATE SAFETY MEASURES INADEQUATE, MISSING INFORMATION ON PRE-SHI
#39528808L
Aug 7, 2024
DEFAULT
$12,500
May 20, 2024Construction CLASS - 1
SUMMONS ISSUED FOR FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. AS PER SSM WORKER WAS INSTALLING ROOF PROTECTION ON 75 DEKALB AVE IN WHICH WORKER WAS NOT TIED OFF AND FELL
#39114842P
Apr 7, 2025
DEFAULT
$12,500
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 8:30 PM ET. BBL 3020850015.