4 floors · 89,838 sq ft · built 1904 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-07-15 (Accepted). Agency page | Dec 31, 2026 in 66 days | 2 of 2 without an accepted 2026 report yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 89,838 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 797 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 6088). Agency page | Dec 31, 2028 in 797 days | Next due 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 18, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT EXIT 5,THE MIDDLE DOOR DOES NOT OPEN AND CLOSE PROPERLY.THE DOOR SADDLE IS BENT UP AND PREVENTS SMOOTH OPERATION.THE DOOR SADDLE NEEDS TO BE CORREC #35727571Z | Jul 15, 2026 POP/IN-VIO | $0 |
| Jul 13, 2022 | Boilers CLASS - 3 OIL SHUTOFF VALVE + ANTI SIPHON VALVE ARE MISSING AT THE TOP OF OIL TANK/OIL LEAK AT BOTH OIL PUMPS/OIL HEATERS NOT REMOVED/VALVE LEAKING AT THE BOTTOM OF THE BOILER WATER FEED TANK;CORRECT VIOLATION AND SUBMIT #39065740X | Jul 27, 2022 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 4, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE IN CODE COMPLIANT MANNER OBSERVED AT EXPOSURE 1(W.ELEV) MISSING BRICKS & CRACKED BRICK FACADE AT EXPOSURE 2 (N ELEV) CRACKED STUCCO WAS OBSERVED. EXP4 (SOUTH ELEV) CRACKED MASONRY WAS OBSERVED. AND AT EXPOSURE 1 (WEST ELEVATION) DAMAGE LINTELS OBSERVED. R #SR31006MA | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 1:23 PM ET. BBL 3060880001.