Brooklyn · Block 2443 · Lot 9 · 11249

90 South 4 Street

3 floors · 2 apartments · 2,872 sq ft · built 1910 · class S2 · owner of record: Heleen Heyning 2025 Revocable Trust

45open violations
$3,750ECB/OATH penalties owed
3HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2012-10-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 48 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 779 days
Next cycle year 2028

Open violations

ECB / OATH (1) · $3,750 owed
IssuedViolationHearingBalance
Feb 14, 2020Construction CLASS - 1
FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER.RECORDS INDICATE NO APPLCATION FILED TO CORRECT,CERTIFY & REMOVE VIOLATIONS CONTAINED IN SUMMMONS #3546077Y.REMEDY:OBTAIN PERMIT COMPLY W/COMMISSIONER'S ORGER.
#35460835N
Aug 7, 2020
DEFAULT
$3,750
DOB (1)
IssuedViolationStatus
Sep 28, 2006CONSTRUCTION

#9191MR
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (44) · C 3 · B 19 · A 12
IssuedClassViolationCorrect by
Mar 17, 2022I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Nov 29, 2023I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Feb 24, 2015ISECTION27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE ?27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A V—
Oct 14, 2015ISECTION27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE ?27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A V—
Jan 8, 2018I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Nov 7, 2019I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Nov 25, 2025I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Dec 4, 2024I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Nov 17, 2022I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Apr 21, 2021I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Oct 26, 2015CSECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM ... AT CELLARNov 3, 2015
Oct 26, 2015BApt 4 · SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING 4 SQ. FT IN THE BATHROOM FROM EAST LOCATED AT APT 4, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHNov 30, 2015
Oct 26, 2015BApt 4 · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MOTORIZED VENTILATOR AT CEILING IN THE BATHROOM FROM EAST LOCATED AT APT 4, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHNov 30, 2015
Oct 26, 2015CApt 4 · SECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHOct 26, 2015
Feb 15, 2011BApt 2 · SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE ... IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTMar 22, 2011
Feb 15, 2011BApt 2 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTMar 22, 2011
Feb 15, 2011BApt 2 · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTMar 22, 2011
May 21, 2010BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDNAT MATERIAL ALL WALLS AND CEILING, ALL STORIES AT PUBLIC HALLJun 25, 2010
May 21, 2010BSECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING HASP AND EYE AT SCUTTLE AT PUBLIC HALLJun 25, 2010
Nov 19, 2009ASECTION 62 M/D LAW REARRANGE TELEVISION AND/OR RADIO ANTENNA TO BE AT LEAST 10 FEET ABOVE ROOF AND NOT ATTACHED TO ANY FIRE ESCAPE OR SOIL OR VENT LINE AT CHIMNEY STACK AT SOUTH SIDE ROOFFeb 22, 2010
Nov 19, 2009BSECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WOOD TREADS # 4,TO 14 SEPARATING FROM INNER STRINGER AT PUBLIC HALL STAIRS, 4th STORYDec 24, 2009
Nov 19, 2009BSECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE HOUSEHOLD ARTICLES AT ROOFDec 24, 2009
Nov 19, 2009BSECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE TWO CLAY TILES AT TOP OF CHIMNEYSTACK AT SOUTH SIDE ROOFDec 24, 2009
Nov 17, 2009BSECTION 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES PLYWOOD AT 3RD STORY BALCONY AT FIRE ESCAPE AT BUILDING FRONTDec 22, 2009
Nov 17, 2009ASECTION 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT FIRE ESCAPE AT BUILDING FRONTFeb 20, 2010
Jun 10, 2008BD26-10.01, 10.05 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS BULKHEAD STAIR TO ROOF.Jul 15, 2008
Jun 10, 2008BD26-19.05 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION ALL STYS PUB HALLS.Jul 15, 2008
Jun 10, 2008BD26-19.01 ADM CODE PROVIDE ADEQUATE LIGHTING CELLAR THRU OUT.Jul 15, 2008
Jun 10, 2008BD26-17.09, 18.01 ADM CODE DISCONTINUE USE OF ILLEGAL SPACE AND/OR HOT WATER HEATER AND PROVIDE FILED FOR & APPROVED HEATER WHICH OBTAINS COMBUSTION AIR DIRECTLY FROM OUTSIDE THE BUILDING OR APPROVED CENTRAL SYSTEM 1 STY PUB HALL FRONT GAS RADIATOR.Jul 15, 2008
Jun 10, 2008BD26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES ALL STYS FRONT.Jul 15, 2008
Jun 10, 2008AD26-41.15 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING.Sep 13, 2008
Jun 10, 2008AD26-19.07 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING NOT LESS THAN 100 WATTS OF INCANDESCENT OR EQUIVALENT.Sep 13, 2008
Jun 10, 2008AD26-10.01 ADM CODE PROVIDE APPROVED FIRE PROOF SELF CLOSING DOOR AT ALL DOOR OPENINGS OTHER THAN ENTRANCE DOOR AT 4TH STY APT.Sep 13, 2008
Jun 10, 2008AD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER BOARD CEILING CELLAR THRU OUT.Sep 13, 2008
Jun 10, 2008AD26-20.01 ADM CODE PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED SO AS TO PERMIT A PERSON INSIDE THE DWELLING TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR ALL APARTMENTS, ALL STORIES.Sep 13, 2008
Jun 10, 2008BD26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOOSE BRICK WORK OF CHIMNEY ROOF EAST.Jul 15, 2008
Jun 10, 2008AD26-10.01 ADM CODE PROVIDE ONE HOUR FIRE RETARDING MATERIAL AS A SEAL FOR TRANSOMS OVER ALL DOOR OPENINGS TO PUBLIC HALL AT 4TH STY APT.Sep 13, 2008
Jun 10, 2008AD26-10.01 ADM CODE PROVIDE APPROVED FIRE PROOF SELF CLOSING DOOR WITH KEY OPERATED DEADBOLT AND LATCH SET PEEPHOLE AND CHAIN DOOR GUARD AT ENTRANCE TO 4TH STY APT.Sep 13, 2008
Jun 10, 2008BD26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS BULKHEAD DOOR TO ROOF.Jul 15, 2008
Jun 10, 2008AD26-21.03 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS ALL STYS PUBLIC HALL.Sep 13, 2008
Jun 10, 2008BD26-11.01, 11.03, 11.05 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CELLAR THROUGHOUT.Jul 15, 2008
Jun 10, 2008AD26-20.08 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING.Sep 13, 2008
Jun 10, 2008ASECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME READILY ACCESSIBLE FOR SIGNATURE, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR AT FRAME MISSING 1ST STY PUBLIC HALL.Sep 13, 2008
Jun 10, 2008CD26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUB HALL AND BOILER ROOM DOOR.Jun 16, 2008

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 13, 2026, 10:48 PM ET. BBL 3024430009.