29 floors · 225 apartments · 344,914 sq ft · built 1931 · class RR · owner of record: 90 John Street Condo Board Of Manag
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 68 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 84 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 344,914 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 189 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 189 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 799 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 69). Agency page | Dec 31, 2029 in 1164 days | Next due 2029 |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $7,188,000 in late-filing or failure-to-file penalties. Agency page | On file | Cycle 10 filing on record: UNSAFE (2026-10-15) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 1, 2026 | Construction CLASS - 2 NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 AGGRAVATED VIOLATION #39185222M ISSUED 4/20/2026, CITING FAILURE TO SAFEGUARD THE PUBLIC/PROPERTY DUE TO A MISSING SIDEWALK SHED PARAPET WALL AND FALLING-OBJECT #39202706K | Nov 5, 2026 PENDING | $1,250 |
| Sep 1, 2026 | Construction CLASS - 2 NO ACCESS TO CELLAR-LEVEL GARAGE. NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE-TO-MAINTAIN VIOLATION #39153945J ISSUED 7/16/2025, CITING HOLES AND STRUCTURAL FAILURE. VIOLATION REMAINS OPEN PENDING #39202707M | Nov 5, 2026 PENDING | $1,250 |
| Sep 1, 2026 | Construction CLASS - 2 NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 VIOLATION #39153940K ISSUED 7/16/2025, CITING UNPERMITTED GAS LINES IN FIRE PUMP ROOM AND ELEVATOR EQUIPMENT ROOM LEADING TO ELEVATOR SHAFTS THROUGHOUT BUILDING. #39202704R | Nov 5, 2026 PENDING | $1,250 |
| Sep 1, 2026 | Construction CLASS - 2 NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 AGGRAVATED(2) VIOLATION #39119689K ISSUED 7/23/2024, CITING FAILURE TO SAFEGUARD THE PUBLIC/PROPERTY DUE TO FALLING DEBRIS AT SIDE WALK SHED REMOVAL AREA. AT INS #39202708Y | Nov 5, 2026 PENDING | $1,250 |
| Sep 1, 2026 | Construction CLASS - 2 NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 AGGRAVATED VIOLATION #35721503J ISSUED 8/1/2025, CITING FAILURE TO SAFEGUARD THE PUBLIC/PROPERTY DUE TO A MISSING SIDEWALK SHED PARAPET WALL AND FALLING-OBJECT H #39202705Z | Nov 5, 2026 PENDING | $1,250 |
| Aug 14, 2026 | Elevators CLASS - 1 VF... R T S.... ELEVATOR IN BUILDING OUT OF SERVICE . UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATING A HAZARDOUS CONDITION ASPER IRCNY 11-02 . REPAIR THE DEVICE AND RESTORE TO SERVICE IMMEDIA #39200699M | Oct 22, 2026 PENDING | $1,250 |
| Jul 31, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION, OBSERVED A SIDEWALK SHED ERECTED AT 90 JOHN STREET DISPLAYING DOB SIDEWALK SHED PERMIT NO. M00957153-I1-SH WITH A EXPIRATION DATE OF 12/04/2025 #39557359H | Oct 8, 2026 DEFAULT | $1,280 |
| Apr 20, 2026 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7A, 8A, AND 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #900196. REMEDY: FILE ACCEPTABLE RE #37036671X | Jul 30, 2026 DEFAULT | $6,250 |
| Apr 20, 2026 | Construction CLASS - 2 NO ACCESS. NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 VIOLATION #39153986X ISSUED 7/16/2025 FOR PVC WASTE LINE AND UNPERMITTED WATER LINE IN THE ELECTRICAL METER ROOM. PERMIT OBTAINED UNDER JOB #M01228006 #39185223Y | Jun 25, 2026 DEFAULT | $6,250 |
| Apr 20, 2026 | Construction CLASS - 2 CERTIFICATE OF CORRECTION NOT OBTAINED FOR CLASS 1 FAILURE TO MAINTAIN VIOLATION #39153940K ISSUED 7/16/2025 FOR UNPERMITTED GAS LINES AT CELLAR AND ELEVATOR. PERMIT OBTAINED UNDER JOB #M01228006-L1-MS BUT VIOL #39185221K | Jun 25, 2026 DEFAULT | $6,250 |
| Apr 20, 2026 | Construction CLASS - 2 NO ACCESS. NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 VIOLATION #39153945J ISSUED 7/16/2025 FOR A LARGE HOLE/STRUCTURAL FAILURE AT THE CELLAR-LEVEL GARAGE. VIOLATION REMAINS OPEN DUE TO LACK OF SUBMITTED #39185224X | Jun 25, 2026 DEFAULT | $6,250 |
| Apr 20, 2026 | Construction CLASS - 1 FAILURE TO SAFEGUARD PERSONS AND PROPERTY DURING CONSTRUCTION OPERATIONS FOR VIOLATION #35721503J ISSUED 8/1/2025. AGGRAVATED CONDITIONS OBSERVED AT EXPOSURE 1: SIDEWALK SHED MISSING PARAPET WALL AT 2ND STORY, #39185222M | Jan 7, 2027 PENDING | $25,000 |
| Mar 30, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OF A 29 STORIES BUILDING I OBSERVED SIDEWALK INSTALLED ON EXPOSURE # 1 AND 3 WITHOUT PARAPET PANEL ON IT TO PREVENT DEBRIS FALLEN INTO THE STREET 3307.6.4.6, FAILURE TO INSTALLED PARAPET #39552394K | Dec 4, 2026 PENDING | $2,400 |
| Mar 25, 2026 | Construction CLASS - 2 SIDEWALK SHED AT EXPOSURE ONE WAS MISSING VERTICAL PARAPET PANELS CONTRARY TO BC-3307.6.4.6 ALSO AREA TO BE PROTECTED WASN'T PROVIDED CONTRARY TO BC-3307.6.3. FAILURE TO COMPLY WITH CODE POSES DANGER TO PUBLIC #39552158Z | Jun 4, 2026 DEFAULT | $10,000 |
| Dec 23, 2025 | Construction CLASS - 2 OBSERVED SUPPORTED PIPE SCAFFOLD ERECTED ON TOP OF A SIDEWALK SHED DECK WITHOUT A PARAPET WALL OR EQUIVALENT EDGE PROTECTION. NO OVERHEAD PROTECTION OR CONTROLLED ACCESS ZONE WAS PROVIDED AT THE SIDEWALK LEVEL. #39548436H | Oct 29, 2026 PENDING | $0 |
| Dec 22, 2025 | Unknown CLASS - 2 AT TIME OF INSPECTION OF A BUILDING UNDER FACADE REPAIR I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE # 1,3 AND 4 UPON REVIEW THE DEPARTMENT RECORD IT SHOWS THAT THE SIDEWALK SHED PERMIT HAD EXPIRED SINCE 12-04 #39548286L | Oct 29, 2026 PENDING | $0 |
| Oct 17, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION ACTIVE SITE WORK IN PROCESS I OBSERVED SUPPORTED SCAFFOLD INSTALLED ON TOP OF THE SIDEWALK SHED. SIDEWALK SHED HAS NO PARAPET PANEL INSTALLED EXPOSURE#1 AND #3 ALSO SIDEWALK SHED NOT EXTE #39546074K | Dec 14, 2026 DEFAULT | $0 |
| Aug 1, 2025 | Construction CLASS - 1 FAILURE TO SAFEGUARD THE PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. AT TIME OF INSPECTION, NO DEBRIS OR PLANKS FALLING AT GRADE HOWEVER, SIDEWALK SHED IS MISSING PARAPET WALL, LEAVING EXPOSED ITEM #35721503J | Apr 16, 2026 IN VIOLATION | $0 |
| Jul 16, 2025 | Construction CLASS - 1 OBSERVED PVC WASTE LINES IN COMMERCIAL SPACE, SURROUNDED BY SEWAGE WASTE. AND NO WATER LINES PERMITTED IN ELECTRICAL METER MECHANICAL ROOMS, LOCATED AT CELLAR LEVEL., REPAIR AND/REPLACE #39153986X | Dec 18, 2026 DEFAULT | $6,250 |
| Jul 16, 2025 | Construction CLASS - 1 OBSERVED WORKERS INSTALLING AC UNITS IN HALLWAYS AGAINST DOB OBJECTIONS/WITHOUT PERMITS, (JOB APPLICATION NO.M01228006) LOCATED THROUGHOUT BUILDING., OBTAIN PERMIT; STOP ALL MECHANICAL WORK. MAKE SITE SAFE. #39153950Y | Dec 18, 2026 DEFAULT | $6,250 |
| Jul 16, 2025 | Construction CLASS - 1 OBSERVED UNPERMITTED GAS LINES FOUND IN FIRE PUMP ROOM WITH INOPERABLE GAUGES LOCATED AT CELLAR LEVEL, AND UNPERMITTED GAS LINES FOUND INSIDE ELEVATOR EQUIPMENT ROOM LEADING TO ELEVATOR SHAFTS LOCATED THROUGHOU #39153940K | Jun 4, 2026 IN VIOLATION | $2,500 |
| Jul 16, 2025 | Construction CLASS - 1 OBSERVED LARGE HOLE/STRUCTURAL FAILURE IN GARAGE LOCATED AT CELLAR LEVEL., REPAIR AND/REPLACE #39153945J | Dec 18, 2026 DEFAULT | $12,500 |
| May 16, 2025 | Elevators CLASS - 2 ADJUST HALL DOORS AND ROLLERS ON 1ST FLOOR TO PREVENT OVERTRAVEL REPAIR PHONE LINES FOR ALL ELEVATOS. #39148213H | Jun 8, 2026 IN VIOLATION | $625 |
| Feb 18, 2025 | Elevators CLASS - 2 CLASS 2: FAILURE TO MAINTAIN RETURN TO SERVICE. #39138662Y | Apr 24, 2025 DEFAULT | $1,562 |
| Nov 15, 2024 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING RECORDS. OBSERVED UNIT 2406 ON 24TH FLOOR IS USED AS A SHARED WORK SPACE FOR TENANTS. C OF O # 120748735 INDICATES APARTMENT HOUSE #39130392R | Feb 20, 2025 IN VIOLATION | $1,250 |
| Oct 30, 2024 | Elevators CLASS - 2 CLASS 2, 97/X/17 RESTORE TO SERVICE FOR PRO INSPECTION BY DOB. #39128970R | Feb 6, 2025 IN VIOLATION | $625 |
| Aug 6, 2024 | Elevators CLASS - 2 97/X/17 CLASS 2 RESTORE TO SERVICE FOR PROPER INSPECTION BY DOB, #39120997K | Oct 10, 2024 DEFAULT | $1,562 |
| Jul 23, 2024 | Construction CLASS - 1 IN PROCESS OF REMOVING SITE SCAFFOLD, DEBRIS ON PLANKS HAVE DISLODGED AND FALLEN TO GRADE., SAFEGUARD PUBLIC AND PROPERTY; STOP ALL EXTERIOR WORK #39119689K | Jul 22, 2025 IN VIOLATION | $0 |
| Aug 17, 2023 | Construction CLASS - 1 AT THE TIME OF INSPECTION 34 STORIES BUILDINGS FULLY OCCUPIED ACTIVE CONSTRUCTION IN PROGRESS, I OBSERVED SIDEWALK SHED WITH SCAFFOLD ERECTED ON SIDEWALK SHED UPON REQUEST FOR LOADS IMPOSED LETTER FOR SHED WHIC #39520673R | Nov 30, 2023 IN VIOLATION | $2,500 |
| Apr 24, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS AND FACADE OBSERVED DAMAGED MORTAR JOINTS IN MULTIPLE LOCATIONS ON EXPOSURE 2 AND 3.REM:MAINTAINBUILDING EXTERIOR WALLS AND FACADE,AND TAKE APPROVED SAFETY MEASURES. #35670243P | Feb 8, 2024 DEFAULT | $6,250 |
| Feb 2, 2023 | Construction CLASS - 1 FAILURE TO PROVIDE ADEQUATE SAFETY MEASURES SUCH AS SHED NETTING ETC WHERE REQUIRED TO PROTECT PUBLIC & PROPERTY FROM DOCUMENTED UNSAFE FACADE AS PER 1RCNY 103-04 FACADE TECHNICAL REPORT FILED AS UNSAFE BY QEWI #35670602H | Sep 14, 2023 DEFAULT | $25,000 |
| Jan 25, 2023 | Construction CLASS - 1 UNLAWFUL ACTS.FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.NOTE:PREVIOUSLY WRITTEN DOB #010923FA010AP DATED 01/09/23 REQUIRED OWNER TO PROVIDE SAFETY MEASURES AT EXP #2.AS OF TODAY 01/25/23 NO SAFETY MEASURES HA #35669473M | Aug 17, 2023 DEFAULT | $12,500 |
| Dec 2, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE8A,9A REPORT OF CRITICAL EXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL900196.SUBMIT ACCEPTABLE REQUIRED TECHNICAL REPORT #37024048X | Feb 23, 2023 IN VIOLATION | $0 |
| Oct 24, 2022 | Elevators CLASS - 1 CLASS 1: 97.X.10 RESTORE TO SERVICE. #39072615M | Aug 31, 2023 DEFAULT | $3,125 |
| Oct 24, 2022 | Elevators CLASS - 2 CLASS 2: 74.E.10 COUNTERWEIGHT FRAME RUBBING AT BOTTOM OF HOISTWAY. LUBRICATE GUIDE RAILS & CHECK SHOES FOR ALIGNMENT . #39072614K | Aug 31, 2023 DEFAULT | $1,562 |
| Jun 6, 2022 | Construction CLASS - 2 SWS IN PLACE,MISSING CAPS FROM THE BOLTS AT SWS CAN CREATE HAZARDOUS CONDITON FOR PEDESTRIONCOMPLY WITH CODE #39501925K | Jul 21, 2022 IN VIOLATION | $2,400 |
| Jun 6, 2022 | Construction CLASS - 2 OBSERVED SIDEWALK SHED PARAPET PANELS IN DANGER OF FALLING AT EXPO#3COMPLY WITH CODE #39501924Z | Jul 21, 2022 IN VIOLATION | $2,400 |
| Oct 8, 2021 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#700196.AGG2 HISTORY OF NONCOMPLIANCE ON#3701914 #37022174H | Nov 28, 2022 IN VIOLATION | $6,250 |
| Sep 15, 2021 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION-MISSING PLASTICCOVER ON SCREW OF SIDEWALK SHED. NOTE: AT THE TIME OF INSPECTION OF ANALTERATION TYPE 2 FACADE BLDG JOB SITE W/NO WORK IN PROGRESS. SIDEWALK #35506553X | Jul 18, 2022 IN VIOLATION | $2,400 |
| Aug 11, 2021 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION.AT TIME OF INSPECTION ON 28 STORY OBSERVED SWS ERECTED AT EXP #1 MISSING CAPS FROM BELTS AND SWS CAN CREATE HAZARDOUS CONDITION FOR PEDESTRIAN.INJURY FROM #35585336H | Mar 24, 2022 DEFAULT | $10,000 |
| May 20, 2021 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS AT THE TIME OF MY INSPECTION OBSERVED SIDEWLAK SHED INSTALLED AT EXP #1,3,& 4 UNDE RPEMRIT #M00118170-SH-EXPIRES 09-30-21 SIDEWALK SHED PARAPET PARTIALLY #35556981H | Mar 24, 2022 IN VIOLATION | $2,400 |
| May 6, 2021 | Construction CLASS - 2 FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATION NOTE AT THE TIME OF MY INSPECTION VIEW IN THE COYRSE OF CONSTRUCTION OPERATION EXPOSURE AREA AT EXPOSURE 3 OPERATION EXPOSURE ARE #35559911X | Jan 13, 2022 DEFAULT | $0 |
| May 6, 2021 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS.FACADE AND APPURTENANCES NOTE AT THE TIME OF MY INSPECTION VIEW AT CORNER OF EXPOSURE 3 AND EXPOSURE 2 MISSING BRICKS AND AT EXPOSURE 2 ADJACENT TO CONSTRUCTION PROJE #35559907N | Jan 13, 2022 DEFAULT | $0 |
| Apr 1, 2021 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 8Z REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #800196.AGG1:PRIOR NOV 37010200Y UNDER 28- #37021242X | May 12, 2022 DEFAULT | $10,000 |
| Jun 3, 2020 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQURIED BY 28-302.5 FOR CONTROL #700196 FILE ACCEPTABLE REPORT #37019143H | May 20, 2021 IN VIOLATION | $0 |
| Mar 24, 2020 | Construction CLASS - 2 FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33.(NO DESIGN DRAWING FOR MATERIAL HOIST SYSTEM)AT TIME OF INSPECTION,OBSERVED ON THE CEILING OF THE MATERIAL HOIST SYSTEM INSTALLED ON THE C #35469624Y | Oct 8, 2020 IN VIOLATION | $625 |
| Mar 24, 2020 | Construction CLASS - 2 FAILURE TO PROVIDE APPROVED PLANS AT JOBSITE.AT TME OF INSPECTION ON AN ACTIVE JOBSITE OF AN EXISTING 28 STORY BUILDING,OBSERVED FACADE WORKUNDER ALT2#14085121.UPON REQUEST FOR APPROVED ARCHITETURAL PLANS,NONE #35469623M | Oct 8, 2020 IN VIOLATION | $9 |
| Aug 28, 2019 | Construction CLASS - 1 3307.6.5.7=INSTALLATION REPORT NOTE AT THE TIME OF MY INSPECTION I OBSERVED A SIDEWALK SHED FULLY INSTTALLED AT ABOVE JOBSITE WHNE ASKED TO PROVIDE INSTALLATION REPORT FOR THE SIDEWLAK SHED NO ONE COULD PROVIDE #35446608M | Feb 6, 2020 IN VIOLATION | $2,100 |
| May 18, 2018 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#800196. REMEDY: SUBMIT REQUIRED TECHNICAL REPORT #37010200Y | Jan 31, 2019 IN VIOLATION | $0 |
| Mar 20, 2017 | Construction CLASS - 2 AT TIME OF INSPECTION SIDEWALK SHED HAS LOOSE/HANGING BRACES & ROTTEN MUD SILLS. SHED NOT BEING MAINTAINED AS PER 3307.6.5.3. REMEDY: COMPLY W/CODE. #35237651R | Aug 10, 2017 IN VIOLATION | $0 |
| Mar 1, 2017 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION. NOTE: AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED ON EXPOSURE #1,3,4 IN NEED OF MAINTENANCE. INCLUDING BUT NOT LIMITED TO DAMAGED, UNSOUND MUDSILLS, #35157207K | Jun 8, 2017 IN VIOLATION | $0 |
| Mar 1, 2017 | Construction CLASS - 2 3307.1. FAILURE TO PROVIDE DAILY INSPECTION LOG OF SIDEWALK SHED. NOTE: AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED WITHOUT ADEQUATE DAILY INSPECTION LOG OR SIX MONTH INSPECTION LOG FROM SIDEWALK SHED COMPAN #35157208M | Jul 20, 2017 IN VIOLATION | $0 |
| Nov 7, 2016 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDMENT REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT. AGG1:PRIOR NOV 36026441P UNDER 28-302.5. REMEDY: FILE ACCEPTABLE AMENDMENT REP #37001327R | Jun 8, 2017 IN VIOLATION | $0 |
| Nov 28, 2014 | Local Law CLASS - 2 FAILURE TO FILE AN ACCEPTABLE AMENDED CYCLE 7 REPORT TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW FISP REPORT. REMEDY: FILE AN AMENDED REPORT FOLLOWING REMEDIAL REPAIR #36026441P | May 21, 2015 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jan 12, 2026 | CONSTRUCTION FTM BLDG IN A CODE COMPLIANTS MANNER. OBSERVED MISSING BRICKSS, DAMAGE DAMAGED MORTAR JOINTS MULIT-LOCATIONS AT EXPOSURE 1 AND 3, NORTH AND SOUTH ELEVATIONS. REMEDY: REPAIR AND OR REPLACE #SR10100YC | DOB VIOLATION - ACTIVE |
| Aug 2, 2024 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00006 | DOB VIOLATION - ACTIVE |
| Jun 23, 2024 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023) #00589 | DOB VIOLATION - ACTIVE |
| May 2, 2024 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00014 | DOB VIOLATION - ACTIVE |
| Jun 22, 2023 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2022) #00044 | DOB VIOLATION - ACTIVE |
| Jan 25, 2023 | HAZARDOUS CONDITION (FACADE) CYCLE 9A UNSAFE REPORT FILED #910666 | DOB VIOLATION - ACTIVE |
| Jan 9, 2023 | CONSTRUCTION EMERGENCY WORK ORDE DUE TO STEP CRACKED BRICKWORK AND VERTICAL CRACKED BRICKWORK. OBSEVED AT EXP2. REMEDY: IMMED TAKE AND PROVIDE SAFETY MEASURES TO SECURE AND PROTECT THE PUBLIC AND INSTALL PUBLIC PROTECTION AT EXP2. ALSO REMOVE/SECURE ANY LOOSE MATERIAL #FA0101AP | DOB VIOLATION - ACTIVE |
| Nov 21, 2022 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2021 #10008 | DOB VIOLATION - ACTIVE |
| Feb 22, 2022 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 #00014 | DOB VIOLATION - ACTIVE |
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #00203 | DOB VIOLATION - ACTIVE |
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #00202 | DOB VIOLATION - ACTIVE |
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #00204 | DOB VIOLATION - ACTIVE |
| May 31, 2018 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 #01729 | DOB VIOLATION - ACTIVE |
| Jan 26, 2018 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST #00260 | DOB VIOLATION - ACTIVE |
| Jan 26, 2018 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST #00259 | DOB VIOLATION - ACTIVE |
| Jan 3, 2017 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST #00252 | DOB VIOLATION - ACTIVE |
| Jan 3, 2017 | ELEVATOR VIO ISSUED TO ELEVATOR-FAIL TO CORRECT DEFFECTS ON 2015 CAT 1 INSP/TST #ACC100254 | DOB VIOLATION - ACTIVE |
| Jan 3, 2017 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST #00253 | DOB VIOLATION - ACTIVE |
| Nov 14, 2016 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST #00320 | DOB VIOLATION - ACTIVE |
| Nov 14, 2016 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST #00321 | DOB VIOLATION - ACTIVE |
| Feb 21, 2012 | LL11/98-LOCAL LAW 11/98 - FACADE UNSAFE LOCAL LAW REPORT FILED #HAZ73422 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Sep 16, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jul 16, 2026 | Facades FTC-FC-UNSAFE Unsafe 10A report filed | Active |
| Jun 1, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Aug 29, 2025 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Nov 25, 2024 | Parking Structures FTF-PS-INITL Failure to file sub cycle 1A compliance report by 12/31/2023 | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Aug 2, 2024 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Jun 23, 2024 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| May 2, 2024 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
Showing 60 of 77. Full list on the agency site.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 15, 2026 | A | Apt 2002 · § 27-2026 ADM CODE REPAIR LEAKY WATER CLOSET FLUSH PIPE CONNECTION AT WATER CLOSET. IN THE BATHROOM LOCATED AT APT 2002, 20th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Jan 18, 2027 |
| Oct 13, 2026 | B | Apt 2002 · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASH BASIN DRAIN PIPE IN THE KITCHEN LOCATED AT APT 2002, 20th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Nov 17, 2026 |
| Oct 13, 2026 | B | Apt 2002 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 2002, 20th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Nov 17, 2026 |
| Oct 13, 2026 | B | Apt 2002 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER BASE CABINET IN THE KITCHEN LOCATED AT APT 2002, 20th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Nov 17, 2026 |
| Oct 13, 2026 | A | Apt 2002 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT EAST WALL. IN THE KITCHEN LOCATED AT APT 2002, 20th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Jan 16, 2027 |
| Oct 13, 2026 | C | Apt 2002 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2002, 20th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Nov 8, 2026 |
| Sep 4, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT PUBLIC HALL, 26th STORY | Dec 8, 2026 |
| Sep 4, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT MATERIA AT CEILING AT PUBLIC HALL, 26th STORY | Oct 9, 2026 |
| Aug 13, 2026 | B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 26th STORY | Sep 17, 2026 |
| Aug 7, 2026 | B | Apt 2001 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THEN 10 SQ FT AT EAST WALL IN THE BATHROOM LOCATED AT APT 2001, 20th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18773299 ISSUED 08-APR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27- | Sep 11, 2026 |
| Jul 20, 2026 | C | Apt 2603 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER DOOR IN THE COMPACTOR CLOSET LOCATED AT PUBLIC PARTS 2603, 26th STORY, 3rd PUBLIC PARTS FROM WEST AT NORTH | Aug 3, 2026 |
| Jun 17, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 26th STORY | Sep 20, 2026 |
| Jun 17, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 26th STORY | Jul 22, 2026 |
| Jun 17, 2026 | B | Apt 2603 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE THE MECHANICAL VENTILATION SYSTEM AT NORTH WALL IN THE BATHROOM LOCATED AT APT 2603, 26th STORY, 3rd APARTMENT FROM WEST AT NORTH | Jul 22, 2026 |
| Jun 8, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 23rd STORY | Jul 13, 2026 |
| Jun 8, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT PUBLIC HALL, 23rd STORY | Sep 11, 2026 |
| Apr 13, 2026 | C | Apt 2002 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2002, 20th STORY, 1st APARTMENT FROM WEST AT NORTH | May 9, 2026 |
| Feb 2, 2026 | C | Apt 3104 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 3104, 31st STORY, 1st APARTMENT FROM EAST AT SOUTH | Feb 16, 2026 |
| Jun 5, 2025 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AT STAIRWAY 'A'' AT PUBLIC HALL STAIRS, 25th STORY | Jun 19, 2025 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 15, 2026 | HPD A | § 27-2026 ADM CODE REPAIR LEAKY WATER CLOSET FLUSH PIPE CONNECTION AT WATER CLOSET. IN THE BATHROOM LOCATED AT APT 2002, 20th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Open |
| Oct 13, 2026 | HPD B | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASH BASIN DRAIN PIPE IN THE KITCHEN LOCATED AT APT 2002, 20th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Open |
| Oct 13, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 2002, 20th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Open |
| Oct 13, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER BASE CABINET IN THE KITCHEN LOCATED AT APT 2002, 20th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Open |
| Oct 13, 2026 | HPD A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT EAST WALL. IN THE KITCHEN LOCATED AT APT 2002, 20th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Open |
| Oct 13, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2002, 20th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Sep 16, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 4, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT PUBLIC HALL, 26th STORY | Open |
| Sep 4, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT MATERIA AT CEILING AT PUBLIC HALL, 26th STORY | Open |
| Sep 1, 2026 | ECB | Construction: NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 AGGRAVATED VIOLATION #39185222M ISSUED 4/20/2026, CITING FAILURE TO SAFEGUARD THE PUBLIC/PROPERTY DUE TO A MISSING SIDEWALK SHED PARAPET WALL AND FALLING-OBJECT | Open |
| Sep 1, 2026 | ECB | Construction: NO ACCESS TO CELLAR-LEVEL GARAGE. NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE-TO-MAINTAIN VIOLATION #39153945J ISSUED 7/16/2025, CITING HOLES AND STRUCTURAL FAILURE. VIOLATION REMAINS OPEN PENDING | Open |
| Sep 1, 2026 | ECB | Construction: NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 VIOLATION #39153940K ISSUED 7/16/2025, CITING UNPERMITTED GAS LINES IN FIRE PUMP ROOM AND ELEVATOR EQUIPMENT ROOM LEADING TO ELEVATOR SHAFTS THROUGHOUT BUILDING. | Open |
| Sep 1, 2026 | ECB | Construction: NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 AGGRAVATED(2) VIOLATION #39119689K ISSUED 7/23/2024, CITING FAILURE TO SAFEGUARD THE PUBLIC/PROPERTY DUE TO FALLING DEBRIS AT SIDE WALK SHED REMOVAL AREA. AT INS | Open |
| Sep 1, 2026 | ECB | Construction: NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 AGGRAVATED VIOLATION #35721503J ISSUED 8/1/2025, CITING FAILURE TO SAFEGUARD THE PUBLIC/PROPERTY DUE TO A MISSING SIDEWALK SHED PARAPET WALL AND FALLING-OBJECT H | Open |
| Aug 14, 2026 | ECB | Elevators: VF... R T S.... ELEVATOR IN BUILDING OUT OF SERVICE . UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATING A HAZARDOUS CONDITION ASPER IRCNY 11-02 . REPAIR THE DEVICE AND RESTORE TO SERVICE IMMEDIA | Open |
| Aug 13, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 26th STORY | Open |
| Aug 7, 2026 | HPD B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THEN 10 SQ FT AT EAST WALL IN THE BATHROOM LOCATED AT APT 2001, 20th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18773299 ISSUED 08-APR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27- | Open |
| Jul 31, 2026 | ECB | Unknown: AT TIME OF INSPECTION, OBSERVED A SIDEWALK SHED ERECTED AT 90 JOHN STREET DISPLAYING DOB SIDEWALK SHED PERMIT NO. M00957153-I1-SH WITH A EXPIRATION DATE OF 12/04/2025 | Open |
| Jul 20, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER DOOR IN THE COMPACTOR CLOSET LOCATED AT PUBLIC PARTS 2603, 26th STORY, 3rd PUBLIC PARTS FROM WEST AT NORTH | Open |
| Jul 20, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WATER DAMAGED, WARPED, LIFTED WOOD FLOORING IN THE PRIVATE HALLWAY LOCATED AT APT 2603, 26th STORY, 3rd APARTMENT FROM WEST AT NORTH | Closed |