5 floors · 110,508 sq ft · built 1931 · class O5 · owner of record: Sutphin Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 110,508 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 185 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 185 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 429 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2027) Likely applies Local Law 87 · Calendar year 2027 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 9677). Agency page | Dec 31, 2027 in 429 days | Next due 2027 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-17 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 8, 2026 | Construction CLASS - 2 REISSUE ON ECB#35725489K FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NO FIRESTOPPING PER BC 712.3;27-345.NOTED:AT CELLAR LEVEL LARGE PORTIONS OF CMU BLOCK APPROXIMATELY 2 FT BY 3 FT IN ELECTRIC METER #35734252R | Jul 15, 2026 POP/IN-VIO | $0 |
| Jun 8, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:WATER PENETRATION THROUGH FOUNDATION WALL SHOWING WATER DAMAGE AND WET SURFACE AND PONDING THROUGHOUT SPRINKLER ROOM AT CELLAR LEVEL OBSERVED UPON INS #35734254K | Jul 15, 2026 POP/IN-VIO | $0 |
| Oct 1, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3; 27-345. NOTED AT CELLAR LEVEL ELECTRIC METER ROOM AND GAS/SPRINKLER VALVE ROOM, BOTH HAVE LARGE PENETRATIONS THROUGH CMU BLO #35725489K | Oct 27, 2025 POP/IN-VIO | $0 |
| Aug 5, 2025 | Boilers CLASS - 2 FOUND RAY PAK H3-1125GAS FIRED BOILER MISSING FIRE DAMPER IN FRESH AIR CORRECT VIOLATING CONDITION AND SUBMIT A CERTIFICATE OF CORRECTION #39155977N | Sep 14, 2026 IN VIOLATION | $1,250 |
| Oct 1, 2024 | Construction CLASS - 1 FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMENTING THE CONDITIONS OF PSID#Q0002345 BY THE AUGUST 1, 2024 DEADLINE. TO DATE, THE DEPARTMENT #37030268Z | Apr 1, 2025 IN VIOLATION | $1,250 |
| Aug 14, 2024 | Boilers CLASS - 2 FAILURE TO MAINTAIN RAYPAK BOILER MODEL# H3-1125. MISSING FIRE DAMPER IN FRESH AIR DUCT. ALSO MISSING REMOTE SHUT OFF SWITCH AT SECOND DOOR. CORRECT VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION. #39121890P | Oct 22, 2024 DEFAULT | $3,125 |
| Jul 25, 2023 | Boilers CLASS - 2 FOUND CAMUS MODEL# DFNH-1100-MSI SERIAL # 111725733 BOILER UNREGISTERED., MAINTAIN BOILER; OBTAIN THE PROPER PERMIT, REGISTER THE BOILER AND SUBMIT A CERTIFICATE OF CORRECTION. #39090902Y | Feb 20, 2024 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 9, 2010 | ELEVATOR #9027/324860 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Report | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 28, 2026, 4:46 PM ET. BBL 4096770007.