Queens · Block 1567 · Lot 6 · 11373

90-12 Whitney Avenue

6 floors · 10 apartments · 16,192 sq ft · built 2020 · class D1 · owner of record: 9012 Whitney Inc.

2open violations
$43,120ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 49 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 49 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 49 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 65 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found

Open violations

ECB / OATH (17) · $43,120 owed
IssuedViolationHearingBalance
Aug 6, 2022Construction CLASS - 1
AT THE TIME OF INSPECTION I OBSERVED, THERE WAS NO HANDRAILS WAS PROVIDED ON PERMANENT STAIRCASE FROM 1ST FLOOR UP TO ROOF LEVEL, WHICH WAS CREATING A HAZARDOUS CONDITION ON JOBSITE.
#39504688J
Jan 10, 2023
IN VIOLATION
$2,500
Apr 7, 2022Construction CLASS - 2
WORK WITHOUT A PERMIT(NEW BUILDING PERMIT EXPIRED)AS NOTED AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE,OBSERVED NEW BUILDING PERMITHAS EXPIRED ON 4/2/2022.PERMIT#421609361-01-NB.OBSERVED THE GATE DOOR
#35647415R
Jul 5, 2022
DEFAULT
$3,125
Sep 24, 2021Construction CLASS - 2
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. AS NOTED: AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION, 6 STORY CONCRETE CAST-IN-PLACE BUILDING MASONRY CMU BLOCK PLACEMEN
#35588754Y
Oct 4, 2022
IN VIOLATION
$1,250
Apr 30, 2021Construction CLASS - 2
FAILURE TO MAINTAIN EMBEDED SAFETY STRAPS INSTALLATION INSPECTION LOG BOOK ON SITE.AS NOTED:AT TIME OF INSPECTION ON ACTIVE CONSTRUCTION SITE OF A 6 STORY CONCRETE CAST-IN-PLACE BUILDING,I OBSERVED CONCRETE IMB
#35549450N
Jul 27, 2021
STIPULATION/IN-VIO
$1,250
Mar 19, 2021Construction CLASS - 1
BC 3307.4.7 WORK ON STORAGE ZONE. NOTE-AT THE TIME OF MY INSPECTION OFA 6 STORY NEW BUILDING. I OBSERVED DUMPSTER CONTAINER ON THE STREET ADJACENT TO SIDEWALK SHED AND NOT ENCLOSED W/ A FENCE,A SOLID BARRIER EX
#35552448L
Oct 5, 2021
IN VIOLATION
$625
Feb 18, 2021Construction CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT ON SITE EXPIRED PERMIT AT THE TIM EOF MY INSPECTION I OBSERVED UPON RESEARCHING BIS AND DOB NOW THAT THE CONSTRUCTION FENCE ON SITE HAD A PERMIT THAT EXPIRED ON 12-21-2020
#35546078M
May 11, 2021
STIPULATION/IN-VIO
$620
Jan 29, 2021Construction CLASS - 1
WORK DOESN'T CONFORM TO APPROVED CONST DOCS &/OR APPROVED AMENDMENTS.@TIME OF INSP ON ACTIVE 6STYNB CONST SITE.NOTICE THAT PLANS/DRAWINGS FOR SIDEWALK SHED WASN'T AS PER WHAT CONTRACTOR ERECTED ON SITE.PLANS CA
#35508602M
May 25, 2021
IN VIOLATION
$2,500
Jan 29, 2021Construction CLASS - 1
3303.11 FAILURE TO MAINTAIN ADEQUATE MEANS OF EGRESS DURING CONST @TIME OF INSP ON ACTIVE 6STYNB CONSTSITE NOTICE@5FL STAIRS IN OR OUT WERE BEING OBSTRUCTED BY REBAR >4'H,CONTRACTOR FAILED TO MAINTAIN ADEQUATE
#35508604X
May 25, 2021
IN VIOLATION
$2,500
Jan 29, 2021Construction CLASS - 1
3309.10 FAILURE TO PROTECT ADJOINING PROPERTIES DURING CONST OR DEMO OPERATION @TIME OF INSP ON ACTIVE 6STYNB CONSTSITE NOTICE@EXP4 OF CONSTSITE CONTRACTOR FAILED TO MAINTAIN/INSTITUTE PROTECTION FOR PROPERTY R
#35508603Y
May 25, 2021
IN VIOLATION
$1,250
Jan 29, 2021Construction CLASS - 1
NO SITE SPECIFIC FORMWORK DESIGN DRAWINGS PRESENT PER3301.7 @TIME OF INSP ON ACTIVE 6STYNB CONST IN FRAMING OF SUPERSTRUCTURE,WHEN REQUEST WAS MADE FOR DRAWINGS FOR FORMWORK&OPENING FOR TEMP STAIRS COMPETENT PE
#35508606J
May 25, 2021
IN VIOLATION
$2,500
Jan 29, 2021Construction CLASS - 1
FAILURE TO INSTITUTE/MAINTAIN ADEQUATE GUARDRAILS ONSITE @TIME OF INSPON ACTIVE 6STYNB CONSTSITE NOTICE@5FLEXP1&INTERIOR CORE ON 5FL@STAIRS MISSING/INADEQUATE GUARDRAILS.THIS IS DANGEROUS IN THAT WORKERS WERE F
#35508605H
May 25, 2021
IN VIOLATION
$2,500
Nov 18, 2020Construction CLASS - 1
BC3307.4 WARNIG SIGNS BARRIERS & SIGNALS AT TIMES OF INSPECTION ON A PROPOSED 6 STORY NB CURRENTLY POURING 2ND FL LEVEL,OBSERVED CONCRETE POURING OPERATION IN PROGRESS.AT EXP#1 OBSERVED A CONCRETE TRUCK CONCR
#35508422P
Mar 30, 2021
IN VIOLATION
$2,500
Nov 18, 2020Construction CLASS - 1
BC3301.13.1 INADEQUATE SITE SAFETY PLAN AT THE TIME OF INSPECTION OF A6 STORY NB CURRENTLY POURING OPERATION IN PROGRESS.AT EXP #1 OBSERVED A CONCRETE TRUCK CONCRETE PUMP & WASHOUT BOX IN ROADWAY W/THE PUMP OUT
#35508421N
Mar 30, 2021
IN VIOLATION
$2,500
Nov 18, 2020Construction CLASS - 1
FAILURE TO PROVIDE PEDESTRIAN PROTECTION FOR SIDEWALKS & WALKWAY.AT THE TIME OF INSPECTION OF A PROPOSED 6 STORY NB I OBSERVED CONCRETE POURING OPERATION IN PROGRESS,2ND FLOOR DECK WAS BEING POWERED OBSERVED
#35508420L
Jun 1, 2021
IN VIOLATION
$10,000
Nov 18, 2020Unknown CLASS - 2
CONSTRUCTION SUPERINTENDENT FAILED TO DO DUTIES AS PER CODE AT THE TIME OF A PROPOSED 6 STORY NB INSPECTION CURRENTLY POURING 2ND FL OBSERVED THE FOLLOWING VIOLATING CONDITIONS IN WHICH THE SITE WAS ISSUED A FU
#35508476K
Mar 30, 2021
IN VIOLATION
$2,500
Nov 18, 2020Construction CLASS - 1
WORK DOESNOT CONFORM TO APPROVED/ACCEPTED DOCUMENTS SSP AT TIME ON A PROPOSED 6 STORY NB CURRENTLY POURING 2ND FL LEVEL OBSERVED FROM WORK FOR 2ND FL EXTENDING OVER LAT.LINE FENCE AT EXP.#4 ABOVE ADJACENT BLD
#35508423R
Mar 30, 2021
IN VIOLATION
$2,500
Nov 18, 2020Construction CLASS - 1
BC1704.1.2 RESPONSIBILITY OF THE SPECIAL INSPECTION AGENCY- INDEPENDENCE AT TIME OF INSPECTION ON A PROPOSED 6 STORY NB CURRENTLY POURING 2ND FL LEVEL OBSERVED CONCRETE POURING OPERATIONS IN PROGRESS & VARIOUS
#35508475Z
Mar 30, 2021
IN VIOLATION
$2,500
DOB (0)

None open.

DOB NOW Safety (2)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 4)
Active
Sep 11, 2024Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Report
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 12, 2026, 3:44 AM ET. BBL 4015670006.

Look up another building