Manhattan · Block 1126 · Lot 26 · 10023

9 West 73 Street

6 floors · 12 apartments · 8,303 sq ft · built 1903 · class D1 · owner of record: 9 West 73rd Street, Llc

26open violations
$8,780ECB/OATH penalties owed
2HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1143 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-08 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (7) · $8,780 owed
IssuedViolationHearingBalance
Jan 21, 2025Elevators CLASS - 1
: CLASS 1 ITEM: NO DOOR LOCK MONITORING INSTALLED ON THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYC BUILDING CODE. THIS IS A FEATURE WHICH ENSURES PASSENGER SAFETY. FILE APPLICATION, INST
#39135962M
Sep 26, 2025
IN VIOLATION
$1,250
Jun 21, 2024Elevators CLASS - 1
RETURN TO SERVICE CLASS 1 CONTINUED
#39117401N
Dec 3, 2026
$3,125
Jun 11, 2024Elevators CLASS - 1
ONLY ELEVATOR IN A MULTIPLE DWELLING OUT OF SERVICE. THIS CONDITION AFFECTS NUMEROUS TENANTS INCLUDING THOSE WITH SPECIAL NEEDS THEREBY CREATING A CONDITION DANGEROUS TO HUMAN LIFE.
#39116538J
Dec 3, 2026
$1,280
Sep 20, 2023Construction CLASS - 2
OBSERVED IN BASEMENT COMMERCIAL GAS DRYER INSTALLED NEXT TO GAS METERS ALSO GAS DRYER VENT IS TERMINATING INTO A BUCKET WHICH CONTRARY FGH SECTION 416.3.5 AND APPENDIX E.3, REPAIR AND/OR REPLACE
#39095265N
Feb 15, 2024
IN VIOLATION
$0
Mar 11, 2022Elevators CLASS - 1
FOUND NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014NYBC. THIS IS A CONTROLLER FEATURES WHICH ENSURE PASSENGER SAFETY. REMEDY : INSTALL DLM AND PERFORM AN
#39057895K
Nov 17, 2022
IN VIOLATION
$3,125
Jan 11, 2022Elevators CLASS - 1
1 . NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY; FILE APPLICATION, INSTALL D
#39054095Z
Jul 7, 2022
IN VIOLATION
$0
Nov 9, 2009Elevators CLASS - 2
98BB5.39BB12.61L10.41T7.98BB PERFORM 7 FILE CURRENT 5YR TEST 39BB RES HACKLE CAR & CWT SHACKLES 61R PROVIDE CONDUIT FOR MAIN LINE WIRES 61M PROVIDE EMERGENCY PHONE # 57R PROVIDE CONDUIT FOR MACHINE BROKE COIL W
#38207154H
May 27, 2010
WRITTEN OFF
$0
DOB (4)
IssuedViolationStatus
Apr 13, 2022FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00027
DOB VIOLATION - ACTIVE
Oct 8, 2010ELEVATOR ANNUAL INSPECTION / TEST

#01376
DOB VIOLATION - ACTIVE
Jan 1, 2009LOCAL LAW 62/91 - BOILERS

#00883
DOB VIOLATION - ACTIVE
Apr 7, 1992LOCAL LAW 10/81 - ELEVATOR
1
#01138
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Report
Active
Apr 13, 2022AEUHAZ FTC-AEU-HAZ
Active
Oct 8, 2010Elevators VCAT1
Active
Jan 1, 2009Boiler LL6291
Active
Apr 7, 1992Elevators LL1081
Active
HPD (10) · C 2 · B 8 · A 0
IssuedClassViolationCorrect by
Oct 15, 2025BApt 1B · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EASTNov 19, 2025
Oct 15, 2025C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BUILDING ENTRANCEOct 21, 2025
Oct 15, 2025BApt 1B · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTLINE AT SINK IN THE KITCHEN LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EASTNov 19, 2025
Oct 15, 2025BApt 1B · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EASTNov 19, 2025
Oct 15, 2025CApt 1B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR LOCK AND ASSEMBLY IN THE ENTRANCE LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOct 21, 2025
Oct 15, 2025BApt 1B · § 27-2005 HMC: REFIT THE DOOR IN THE ENTRANCE LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EASTNov 19, 2025
Oct 15, 2025BApt 1B · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EASTNov 19, 2025
Oct 15, 2025BApt 1B · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EASTNov 19, 2025
Oct 15, 2025BApt 1B · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTLINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EASTNov 19, 2025
Oct 15, 2025BApt 1B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GLASS AT LOWER WINDOW SASH AT EAST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EASTNov 19, 2025

Issued in the last 120 days

DateSourceWhatNow
Jul 31, 2026ECBElevators: CLASS 2 ITEMS: EXCESSIVE MOVEMENT OBSERVED AT CAR GUIDE SHOES, INDICATING IMPROPER GUIDANCE ALONG RAILS. EQUIPMENT NOT MAINTAINED IN PROPER CONDITION, IN VIOLATION OF ASME A17.1-2013 2.23.1, 8.6.4.7, AND 8.6.1.Closed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 9:28 AM ET. BBL 1011260026.

Look up another building