1 floors · 31,574 sq ft · built 1946 · class E9 · owner of record: 1130 Tiffany Street Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 31,574 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1143 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 11, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED ACTIVE DEMOLITION ACTIVITIES. UPON REQUESTING THE LOAD IMPOSED LETTER FOR HAVING A SUPPORTED SCAFFOLD ON TOP OF A SIDEWALK SHED AT EXPOSURE 1 IT WAS NOT PROVIDED. CONDITION CONTRA #39559085Z | Nov 20, 2026 | $1,250 |
| Jun 17, 2026 | Unknown CLASS - 1 AT THE TIME OF INSPECTION OF A 4-STORY BUILDING UNDER FULL DEMOLITION, ACTIVE SITE UPON REQUESTING COMPETENT PERSON ONSITE FOR PRE SHIFT MEETING, I REVIEW THE SCOPE OF WORK TO BE DONE THERE WAS NO HEADING MENTI #39555665R | Feb 26, 2027 | $5,000 |
| Jun 17, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OF A 4-STORY BUILDING UNDER FULL DEMOLITION, ACTIVE SITE I OBSERVED AT ROOF LEVEL EXTERIOR A-FRAME LADDER BEGIN USE TO ACCESS PIPE SCAFFOLDING A-FRAME LADDER WAS CLOSED TIGHT AND LEANING A #39555663N | Feb 26, 2027 | $1,250 |
| Jun 17, 2026 | Construction CLASS - 1 RESPONDING TO AN INCIDENT WHERE A WORKER INSTALLING A DEBRIS CHUTE AT ROOF LEVEL WAS TIED OFF TO A MOTOR SECURED TO AN I-BEAM AT AN ELEVATOR SHAFT OPENING. WHILE ANOTHER WORKER CUT THE SAME I-BEAM, IT DROPPED A #39555666Z | Feb 26, 2027 | $10,000 |
| Jun 17, 2026 | Unknown CLASS - 2 WORKER INJURED AT ROOF-LEVEL DURING CHUTE INSTALLATION AT A 4-STORY BUILDING UNDER FULL DEMOLITION. INCIDENT AREA WAS NOT MAINTAINED IN ITS ORIGINAL CONDITION. UPON INSPECTION, TOOLS AND EQUIPMENT INVOLVED IN T #39555674Z | Mar 12, 2027 | $2,500 |
| Jun 17, 2026 | Unknown CLASS - 2 AT THE TIME OF INSPECTION OF A 4-STORY BUILDING UNDER FULL DEMOLITION, AT ROOF LEVEL WORKERS WERE USING GAS POWER SAW FOR CUTTING I-BEAMS AT ELEVATOR SHAFT PIT. UPON REQUESTING THE FIRE WATCH DURING CUTTING OPE #39555675K | Mar 12, 2027 | $2,500 |
| Jun 17, 2026 | Construction CLASS - 1 RESPONDING TO AN INCIDENT WHERE A WORKER WAS AT ROOF LEVEL WORKING ON DEBRIS CHUTE, WORKER WHO WAS AT ROOF LEVEL TIGHT OF TO MOTOR INSIDE ELEVATOR SHAFT ON I-BEAM AT ROOF LEVEL, I-BEAM DROPPED PULLING WORKER TI #39555664P | Feb 26, 2027 | $5,000 |
| Issued | Violation | Status |
|---|---|---|
| Feb 2, 2023 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00094 | DOB VIOLATION - ACTIVE |
| Dec 1, 2022 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2200653 | DOB VIOLATION - ACTIVE |
| Nov 2, 2022 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00123 | DOB VIOLATION - ACTIVE |
| Aug 2, 2022 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00191 | DOB VIOLATION - ACTIVE |
| Jun 1, 2022 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00345 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 6, 2026 | GHG Emissions - LL97 FTF-EN-LL97320 FAILURE TO FILE AN ANNUAL BUILDINGS EMISSIONS REPORT AS REQUIRED BY AD CODE SEC. 28-320.3.7 IN ACCORDANCE WITH 1 RCNY § 103-14. | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Sep 25, 2026 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Jun 22, 2026 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Mar 6, 2026 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Dec 3, 2025 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Sep 26, 2025 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 2) | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 2) | Active |
| Feb 28, 2025 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Feb 2, 2023 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Dec 1, 2022 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Nov 2, 2022 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Aug 2, 2022 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Jun 1, 2022 | Benchmarking - LL84 FTF-EN-BENCH | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Nov 6, 2026 | DOB Safety | GHG Emissions - LL97: FAILURE TO FILE AN ANNUAL BUILDINGS EMISSIONS REPORT AS REQUIRED BY AD CODE SEC. 28-320.3.7 IN ACCORDANCE WITH 1 RCNY § 103-14. | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Open |
| Sep 11, 2026 | ECB | Construction: AT TIME OF INSPECTION OBSERVED ACTIVE DEMOLITION ACTIVITIES. UPON REQUESTING THE LOAD IMPOSED LETTER FOR HAVING A SUPPORTED SCAFFOLD ON TOP OF A SIDEWALK SHED AT EXPOSURE 1 IT WAS NOT PROVIDED. CONDITION CONTRA | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 1:11 PM ET. BBL 2027060082.