10 floors · 52 apartments · 62,738 sq ft · built 1962 · class D4 · owner of record: Harbor View Towers Tenants Cor
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 69 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 69 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 85 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 62,738 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 190 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 190 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 800 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 6058). Agency page | Dec 31, 2028 in 800 days | Next due 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-01 (Accepted). Agency page | On file | 2026 reports accepted |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $108,000 in late-filing or failure-to-file penalties. Agency page | On file | Cycle 10 filing on record: SAFE (2026-10-15) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 9, 2025 | Unknown CLASS - 2 FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF CELLAR LEVEL, OBSERVED CRACKED/SPALLING CONCRETE AT BEAMS AND SLABS ANS EXP #35693967M | Mar 1, 2027 PENDING | $1,280 |
| Oct 1, 2024 | Construction CLASS - 1 FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE OR A PERIODIC INSPECTION OF A PARKING STRUCTURE(PIPS) REPORT DOCUMENTING THE CONDITIONS OF PSID#B000 #37031280X | Jul 10, 2025 IN VIOLATION | $1,250 |
| Dec 29, 2021 | Construction CLASS - 2 FAILURE TO COMPLY DOB PERMIT SIGN OFF. NOTE: RESPONDANT OBTAINED JOB#320787225 EXP 05/06/2014, JOB#320392124 EXP 03/012012, JOB #310024746 EXP04/01/2010, JOB #320836752 EXP 12/06/14, ALL PERMITS MENTIONED WAS N #39053571X | Sep 19, 2022 IN VIOLATION | $0 |
| Jan 21, 2021 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES.AS NOTEDAT TIME OF INSPECTION A OBSERVED ON EXPOSURES 1,2,3 & 4 SPALLING BRICKS & CRACK BRICKS.EXPOSURE# 1 CORRODED BALCONY SUPPORT BEAMS,SPALLING B #35549389N | Jul 7, 2021 IN VIOLATION | $0 |
| Feb 27, 2019 | Elevators CLASS - 1 CLASS 1 ITEM: MISALIGND ZONE LOCK RESTRICTOR. EVEN THOUGH CAR DOOR CANNOT BE MANUALLY OPENED, ZONE LOCK MUST STILL BE OPERATIONAL. CLASS 2 ITEMS:ADJUST BRAILLE TAGS TO ADA CODE HEIGHT. PROVIDE MISSING BRAILLE #39001455Y | Apr 20, 2020 IN VIOLATION | $0 |
| Nov 14, 2018 | Elevators CLASS - 1 CEASE USE 05A10(C/U),57B07,52M07. 05-1-10 CEASE USE ITEM,DOOR ZONE RESTRICTOR HAS BEEN RENDERD INOPERATIVE THIS IS A SAFETY DEVICE TO ENSURE PASSERNGER SAFETY:REMEDY:REPAIR RESTRICTOR AND CONTACT NYC BOD AT EIR #38266242H | May 20, 2019 IN VIOLATION | $0 |
| May 18, 2017 | Construction CLASS - 2 FAILURE TO PROVIDE INFORMATION PANEL. NOTE: @ TIME OF INSP OBSERVED SIDEWALK SHED IN PLACE W/OUT INFORMATION PANEL ON PARAPET. REM: COMPLY W/ CODE. #35238069X | Jul 3, 2017 IN VIOLATION | $0 |
| May 29, 2015 | Local Law CLASS - 2 FAILURE TO FILE AN ACCEPTABLE AMENDED CYCLE 7 REPORT TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW FISP REPORT. REMEDY: FILE AN AMENDED REPORT FOLLOWING REMEDIAL REPAIR #36027643H | Dec 21, 2015 IN VIOLATION | $0 |
| Mar 4, 2008 | Plumbing Non-Hazardous PORTABLE WATER PIPING CROSS CONNECTED TO NON-PORTABLE WATER PIPING - HAZARDOUS. PART OF SPRINKLER SYSTEM (FROM SHORE RD SIDE OF BLDG) FOR OUTSIDE SPRINKLER OF GRASS DOES NOT HAVE PROTECTIVE DEVICES FROM #34634228M | Aug 27, 2008 DEFAULT | $0 |
| Oct 13, 2006 | Boilers Hazardous B4B/34A/50A/50B/50C/50D/50E/50F/50A-RETURN PUMP LEAKING/50B-MUD LEG CORRODED & LEAKING/50E-HOLES IN BOILER ROOM WALLS & CEILING/50F-SAFETY OR RELIEF VALVE DEFECTIVE #32051411N | Nov 27, 2006 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 20, 2023 | HAZARDOUS CONDITION (FACADE) CYCLE 9B UNSAFE REPORT FILED #910874 | DOB VIOLATION - ACTIVE |
| May 7, 2020 | ELEVATOR #9028/680579 | DOB VIOLATION - ACTIVE |
| May 7, 2020 | ELEVATOR #9028/680580 | DOB VIOLATION - ACTIVE |
| May 29, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00521 | DOB VIOLATION - ACTIVE |
| Feb 6, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00360 | DOB VIOLATION - ACTIVE |
| Aug 7, 2015 | CONSTRUCTION DUE TO A MOTOR VEHICLE CRASHED INTO THE BUILDING SIDE WALK SHED INSTALLED #ER05DL | DOB VIOLATION - ACTIVE |
| Aug 30, 2013 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 7B TECHNICAL REPORT BY 08/21/2012 #01541 | DOB VIOLATION - ACTIVE |
| Jun 11, 2010 | ELEVATOR #9027/341314 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 23, 2026 | Parking Structures FTF-PS-INITL Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13 | Active |
| Feb 20, 2023 | Facades FISPHAZ CYCLE 9B UNSAFE REPORT FILED | Active |
| May 29, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 6, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Aug 30, 2013 | Facades FISPNRF FAILED TO FILE FISP CYCLE 7B TECHNICAL REPORT BY 08/21/2012 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 5, 2025 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF KEY OPERATED DOUBLE CYLINDER LOCK INSTALLED AT BUILDING ENTRANCE DOOR | Aug 11, 2025 |
| Apr 6, 2022 | B | Apt 1B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULK AROUND BATHTUB AND WALL TILE IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | May 11, 2022 |
| Apr 6, 2022 | B | Apt 10A · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING, IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 10A, 10th STORY, APARTMENT AT NORTH | May 11, 2022 |
| Apr 6, 2022 | B | Apt 10A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR , THE CEILING, IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 10A, 10th STORY, APARTMENT AT NORTH | May 11, 2022 |
| Apr 6, 2022 | B | Apt 1B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE EAST WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | May 11, 2022 |
| Apr 6, 2022 | B | Apt 1B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL. IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | May 11, 2022 |
| Apr 6, 2022 | B | Apt 1B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | May 11, 2022 |
| Apr 6, 2022 | A | Apt 1B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Jul 10, 2022 |
| Apr 6, 2022 | B | Apt 1B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | May 11, 2022 |
| Apr 6, 2022 | A | Apt 1B · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE WINDOW STOOLS. IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Jul 10, 2022 |
| Apr 6, 2022 | B | Apt 1B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | May 11, 2022 |
| Apr 6, 2022 | A | Apt 1B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WINDOW STOOL AT ALL WINDOWS IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Jul 10, 2022 |
| Apr 6, 2022 | B | Apt 10A · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING, IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 10A, 10th STORY, APARTMENT AT NORTH | May 11, 2022 |
| Apr 6, 2022 | B | Apt 10A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR , THE CEILING, IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 10A, 10th STORY, APARTMENT AT NORTH | May 11, 2022 |
| Jun 10, 2015 | B | Apt 1B · SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... 4 SQ.FT. AT EAST WALL, UNDER WINDOW IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Jul 15, 2015 |
| Jun 4, 2015 | A | Apt 1B · SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT THE EAST WALL APPROX. 3SQ.FT. IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 7, 2015 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 23, 2026 | DOB Safety | Parking Structures: Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13 | Open |
| Jul 16, 2026 | DOB Safety | Facades: Unsafe 10B report filed | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 23, 2026, 8:49 AM ET. BBL 3060580012.