16 floors · 146,161 sq ft · built 1912 · class O6 · owner of record: Madison 29 Holding Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2023-03-28 (Accepted). Agency page | Dec 31, 2026 in 64 days | 1 of 1 without an accepted 2026 report yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 146,161 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 185 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 185 days | Annual filing |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 858). Agency page | Dec 31, 2028 in 795 days | Next due 2028 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1160 days | Next cycle year 2029 |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $1,063,860 in late-filing or failure-to-file penalties. Agency page | On file | Cycle 10 filing on record: UNSAFE (2026-07-09) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jan 6, 2026 | Unknown CLASS - 2 3301.8.2 EVIDENCE TAMPERING. RESPONDED TO AN INCIDENT INVOLVING A PLUMBER WHO WAS STRUCK ON THE HEAD BY A DOOR FRAME THAT HAD BEEN LEANING AGAINST A METAL STUD. UPON ARRIVAL THE DOOR FRAME INVOLVED IN THE INCID #39548806X | May 24, 2027 | $2,500 |
| Jan 6, 2026 | Unknown CLASS - 2 3303.4.5 INADEQUATE STORAGE. RESPONDED TO AN INCIDENT INVOLVING A PLUMBER WHO WAS STRUCK ON THE HEAD BY A DOOR FRAME THAT HAD BEEN LEANING AGAINST A METAL STUD. INSPECTION REVEALED THAT THE DOOR FRAME LEANING O #39548807H | May 24, 2027 | $2,500 |
| Jan 16, 2024 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B AND 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.4 FOR CONTROL#902407.REM:FILE ACCEPTABLE REPORT. #37026366K | Jul 15, 2024 ADMIT/IN-VIO | $0 |
| Oct 18, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENCES.*WEST ELEVATION EXPOSURE 1,OBSERVED OVERHANGING TREE BRANCH ON ROOFLEVEL'CRACKED DECORATIVE STONES ON 4TH AND 5TH FLOORS NORTH WEST CORNER.*NORTH ELE #35365144Z | Dec 13, 2018 IN VIOLATION | $0 |
| Apr 19, 2006 | Local Law Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL. SEVERE MASONRY FRACTURE OF WALL AND WATER TABLE, MOVEMENT OF TRRACOTTA COMPONENTS WITH UNPREDICTABLESTRUCTURAL INTEGRITY OVER PUBLIC SIDEWALK-AT THE NE CORNER OF 15TH FLR #34416787N | Sep 27, 2007 DEFAULT | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #02744 | DOB VIOLATION - ACTIVE |
| Sep 18, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION AT EXPOSURE 3 (EAST ELEVATION) IT WAS OBSERVED DETERIORATED MORTAR JOINTS & CRACKED TERRA COTTA. AT EXPOSURE 4 (SOUTH ELEVATION) CRACKED TERRA COTTA WAS OBSERVED #SR10504MA | DOB VIOLATION - ACTIVE |
| Apr 24, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBERSERVED AT EXP 1 STONE 3 FL, DAMAGED AT GABLE ROOF PAPER. EXPOSURE2 CRACK WATER TABLE & WINDOW LINTEL 3 FL. EXP 3 SPALLING ERODED MORTAR JOINTS. EXP4 CRACK WINDOW PANE @ SET BACK FACING EXP 3.ROOF BRKN SKYLIGHT CRACK, OPEN, JOINTS & SPALLING ALL #SR0503NS | DOB VIOLATION - ACTIVE |
| Jan 24, 2022 | HAZARDOUS CONDITION (FACADE) CYCLE 9B UNSAFE REPORT FILED #909583 | DOB VIOLATION - ACTIVE |
| Jan 24, 2022 | FAILURE TO CORRECT SWARMP CONDITIONS (FACADE) CYCLE 9B FAILURE TO CORRECT SWARMP CONDITIONS #00202 | DOB VIOLATION - ACTIVE |
| Nov 12, 2019 | SPRINKLER FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019 #NRF00087 | DOB VIOLATION - ACTIVE |
| Mar 31, 2008 | EMERGENCY POWER #NRF00397 | DOB VIOLATION - ACTIVE |
| Apr 21, 1997 | CONSTRUCTION #05C3 | VIOLATION UNSERVED ECB-ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Aug 19, 2026 | Facades FTC-FC-UNSAFE Unsafe 10B report filed | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Jan 24, 2022 | Facades FISPFCS CYCLE 9B FAILURE TO CORRECT SWARMP CONDITIONS | Active |
| Jan 24, 2022 | Facades FISPHAZ CYCLE 9B UNSAFE REPORT FILED | Active |
| Nov 12, 2019 | Sprinklers FTF-SP-FINAL | Active |
| Mar 31, 2008 | Emergency Power FTF-EL-ENRF | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 19, 2026 | DOB Safety | Facades: Unsafe 10B report filed | Open |