Brooklyn · Block 6465 · Lot 94 · 11214

8845 19 Avenue

2 floors · 2 apartments · 2,596 sq ft · built 1940 · class S2 · owner of record: Hafez Ashraf H

2open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
426dto Gas piping inspection (2027 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 61 days
Keep the report on file (not filed with DOB)
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 305 days
Required only if the owner doesn't live there
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 426 days
Next cycle year 2027

Open violations

ECB / OATH (0)

None open.

DOB (2)
IssuedViolationStatus
Jun 9, 2009CONSTRUCTION
WORK DOES NOT COMFORM TO APPROVED CONSTRICTION DOCUMENTS OR APPROV ED AMENDMENTS. THE THE ELEVATIONS RAFTER RIDGE SIZE ARE CONTRARY. THE COLLAR BEAMS ARE TOO HIGH AND TO SMALL, ROOF RAFTERS HAVE NO DETAILS T O THE WALL AND 302362663 AL EXISTING MALL, REMEDY: STOP ALL WORK. CONFORM TO APPROVED DOCUME
#ID02MG
DOB VIOLATION - ACTIVE
May 26, 2009CONSTRUCTION
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR APPROV ED AMENDMENTS PLANS CALL FOR ROOF RAFTERS TO SIT INTO PARTY WALL OR ON TO CEMENT BLOCK WALL CONTRATOR HAS RAFTERS SITTING ON NEW INTERIOR PA RTITION WALL PLANS CALL FOR 2ND FLOOR JOIST TO SIT INTO PARTY WALL REM EDY: CONFORM TO A
#EX1109RBO
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 31, 2026, 12:08 PM ET. BBL 3064650094.