4 floors · 20 apartments · 18,000 sq ft · built 1930 · class C1 · owner of record: Nyc Department Of Homeless Services
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 63 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 63 days | Annual |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-07 (Accepted). Agency page | Dec 31, 2026 in 63 days | 1 of 2 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 79 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1159 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 17, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED FIRE ESCAPE DROP LADDER. OBSTRUCTED BY FIXED BENCH. LOCATED AT EXPOSURE 1. PREVIOUS VIO#3A18763, REPAIR AND/REPLACE #39192910L | Jul 9, 2026 POP/IN-VIO | $0 |
| Jun 17, 2026 | Boilers CLASS - 2 HYDROTHERM BOILER MISSING RATINGS LABEL, MOTORIZED COMBUSTION AIR LOUVER MISSING WHISKER SWITCH. CORRECT VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION. #39192819K | Jul 9, 2026 POP/IN-VIO | $0 |
| Jun 24, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATIONS. THROUGHOUT BASEMENT LEVEL. POTENTIAL FIRE HAZARD., PR #39151853N | Jun 30, 2025 POP/IN-VIO | $0 |
| Jun 24, 2025 | Construction CLASS - 1 & BC 1024.2 (2022 CODE) FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. FIRE ESCAPE OBSTRUCTED WITH FIXED PARK BENCH EXPOSURE 2 AND TREE LEAVES AND BRANCHES OBSTRUCTING AT EXPOSURE 3. POTENTIAL HAZARD., REMOVE #39151854P | Jun 30, 2025 POP/IN-VIO | $0 |
| Apr 30, 2024 | Boilers CLASS - 2 HYDROTHERM MODEL-MR1200 BOILER. MISSING BOILER RATING TAG, MISSING WISKER SWITCH ON FRESH AIR LOUVER. CORRECT VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION. #39112986P | Jun 13, 2024 POP/IN-VIO | $0 |
| Aug 31, 2022 | Construction CLASS - 2 AT CELLAR/BASEMENT LEVEL JIM CAP INSTALLED AND ALSO NOT HOLDING ON 4 INCH CAST IRON FITTING. THIS IS A HAZARDOUS CONDITION BECAUSE IT ALLOWS WASTE WATER AND ALSO BACTERIA TO SEEP INTO OPEN AREAS., REPAIR AND/OR #39069230Y | Sep 20, 2022 POP/IN-VIO | $0 |
| Aug 31, 2022 | Unknown CLASS - 2 I OBSERVED IN THE PREVIOUS LAUNDRY ROOM IN THE BASEMENT THE UNPERMITTED USE OF A FLEXIBLE CORD AS PERMANENT WIRING SUPPLYING POWER TO AN IN-WALL INSTALLED VENTILATION FAN; 400.8. REMEDY: COMPLY WITH EC CODE; #39069438N | Feb 1, 2023 POP/IN-VIO | $0 |
| Aug 31, 2022 | Unknown CLASS - 2 I OBSERVED IN THE BASEMENT ELECTRICAL EQUIPMENT ROOM THE GROUND CONDUITS IN A STATE OF CORROSION. ALL SECTIONS OF THE GROUND MUST BE COMPLETE MECHANICAL CONDITION. ALSO NOTED NO WATER METER JUMPER INSTALLED. RE #39069439P | Feb 1, 2023 POP/IN-VIO | $0 |
| Sep 24, 2021 | Boilers CLASS - 2 SAFETY DISCHARGE PIPE INCORRECT/FRONT JACKET NOT IN PLACE/OPENING IN BOILER ROOM DOOR/DEBRIS IN BOILER ROOM;CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION #39048113M | Oct 15, 2021 POP/IN-VIO | $0 |
| Sep 24, 2021 | Boilers CLASS - 2 #1 CIRCULATOR CORRODED AND GAUGE IS DEFECTIVE/MOTORIZED LOUVER NOT INTERLOCKED WITH ALL UNITS AND WHISKER SWITCH INSTALLED/BOILER RATING TAG MISSING;CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION #39048114Y | Oct 15, 2021 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #35856 | DOB VIOLATION - ACTIVE |
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 29, 2026, 1:00 AM ET. BBL 3040770024.