Brooklyn · Block 5665 · Lot 41 · 11220

882 53 Street

7 floors · 8 apartments · 13,872 sq ft · built 2025 · class D7 · owner of record: 28 Property Llc

8open violations
$70,309ECB/OATH penalties owed
1HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 118 days
No Cycle 10 report on record yet
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 431 days
Next cycle year 2027

Open violations

ECB / OATH (8) · $70,309 owed
IssuedViolationHearingBalance
Oct 21, 2021Construction CLASS - 1
BC3309.9 WEATHERPROOF INTEGRITY OF ADJOINING BLDGS.NOTE-ATOI I OBSERVED MULTIPLE LOCATION THAT JOISTS FROM EXISTING STRUCTURE WERE REMOVED&WERENT WEATHERPROOFED@ADJOINING PROPERTY WALL@EXP4.THIS CREATES UNSAFE
#35632195M
Mar 30, 2022
DEFAULT
$6,250
Oct 21, 2021Construction CLASS - 1
UNLAWFULLY CONTS WORK WHILE ON NOTICE OF SWO.NOTE-ATOI I OBSERVED DEMOWORK HAD CONTD WHILE ON NOTICE OF FULL SWO UNDER COMPLAINT3815788.BLDGCURRENTLY@GRADE LEVEL.NO WORK SHALL TAKE PLACE W/FULL SWO ON JOBSITE.S
#35632193Z
Mar 30, 2022
DEFAULT
$12,500
Oct 21, 2021Construction CLASS - 1
FAILURE TO SAFEGUARD ALL PERSONS&PROPERTY AFFECTED BY DEMO OPERATIONS.NOTE:ATOI I OBSERVED FIRE ESCAPE@EXP3 THAT WAS ATTACHED TO SITE&ADJ ADJ PROPERTY HAS BEEN CUT&MODIFIED.THERES NO PROTECTIVE ENDRAIL TO SAFEG
#35632194K
Mar 30, 2022
DEFAULT
$12,500
Sep 28, 2021Construction CLASS - 1
FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.NOTE:AT THE TIME OF INSPECTION OF A 2 STORY DEMO SITE IN PROGRESS I OBSERVED LARGE AMOUNT OF COMBUSTIBLE DEBRIS INSIDE THE SITE & AROUND THE PE
#35505648Y
Jun 27, 2022
DEFAULT
$6,250
Sep 28, 2021Construction CLASS - 1
FAILURE TO INSTITUTE & MAINTAIN SAFETY MEASURES.NOTE:AT THE TIME OF INSPECTION OF A 2 STORY DEMO SITE THE FOLLOWING HAZARDOUS CONDITIONS WERE OBSERVED (1)NO OVERHEAD PROTECTION AT EXP.#3 & EXP.#1 ADJACENT PROPE
#35505646K
Jun 27, 2022
DEFAULT
$12,500
Sep 28, 2021Construction CLASS - 1
BC3306.9.8.3 GLASS NOTE:AT THE TIME OF INSPECTION OF A 2 STORY DEMO SITE IN PROGRESS I OBSERVED THE WINDOWS HAVE NOT BEEN REMOVED.PRIOR TO THE COMMENCEMENT OF DEMOLITION ALL GLASS LOCATED IN THE AREA SHALL BE
#35505647M
Jun 27, 2022
DEFAULT
$6,250
Sep 28, 2021Construction CLASS - 1
FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY DEMO OPERATIONS.NOTE:AT THE TIME OF INSPECTION OF A 2 STORY DEMO SITE IN PROGRESS AT2ND LEVEL I OBSERVED THERE WAS A SHARED FIRE ESCAPE AT EXP.#3 W/ADJOIN
#35505645Z
Jun 27, 2022
DEFAULT
$12,500
Sep 28, 2021Construction CLASS - 1
FAILURE TO PROVIDE SIDEWALK SHED WHERE REQUIRED.NOTE:AT THE TIME OF INSPECTION OF AN ACTIVE DEMO SITE THAT WAS 27 FT IN HEIGHT I OBSERVED THERE WAS NO SIDEWALK SHED IN PLACE AS REQUIRED.THIS CREATED A UNSAFE &
#35505644R
Jun 27, 2022
DEFAULT
$1,559
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (8) · C 1 · B 0 · A 7
IssuedClassViolationCorrect by
Oct 2, 2026A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING FRAME AT PUBLIC HALL, 1st STORYJan 5, 2027
Oct 2, 2026A§27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS MISSING NOTICEJan 5, 2027
Oct 2, 2026A§27-2045(B)(5) HMC, § 12-01 RCNY POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAILBOX MISSING NOTICE AT PUBLIC HALL, 1st STORYJan 5, 2027
Oct 2, 2026A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING.Jan 5, 2027
Oct 2, 2026A§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER.Jan 5, 2027
Oct 2, 2026A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD.Jan 5, 2027
Oct 2, 2026A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTEDJan 5, 2027
Oct 2, 2026C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING NOTICE AT PUBLIC HALL, 1st STORYOct 8, 2026

Issued in the last 120 days

DateSourceWhatNow
Oct 2, 2026HPD A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING FRAME AT PUBLIC HALL, 1st STORYOpen
Oct 2, 2026HPD A§27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS MISSING NOTICEOpen
Oct 2, 2026HPD A§27-2045(B)(5) HMC, § 12-01 RCNY POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAILBOX MISSING NOTICE AT PUBLIC HALL, 1st STORYOpen
Oct 2, 2026HPD A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING.Open
Oct 2, 2026HPD A§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER.Open
Oct 2, 2026HPD A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD.Open
Oct 2, 2026HPD A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTEDOpen
Oct 2, 2026HPD C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING NOTICE AT PUBLIC HALL, 1st STORYOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 8:04 PM ET. BBL 3056650041.