3 floors · 187,000 sq ft · built 1972 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-16 (Accepted). Agency page | Dec 31, 2026 in 67 days | 3 of 3 without an accepted 2026 report yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 187,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 188 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 188 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 432 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 9919). Agency page | Dec 31, 2029 in 1163 days | Next due 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 9, 2026 | Construction CLASS - 2 REISSUED ECB#35725597H FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NO FIRESTOPPING PER BC 712.3;27-345.NOTED MISSING FIREPROOFING AT ELECTRICAL METER ROOM.REM:PROVIDE/MAINTAIN FIRESTOPPING. #35731904J | Jul 15, 2026 POP/IN-VIO | $0 |
| Sep 25, 2025 | Construction CLASS - 2 REISSUE ECB #35663559X. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANTMAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT ROOFTOP INSIDE THE PARAPET MISSING FLASHING AND ALUMINUM PANELS THROUGHOUT ROOFTOP INC #35725525Z | Oct 23, 2025 POP/IN-VIO | $0 |
| Sep 25, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NO FIRESTOPPINGPER BC 712.3; 27-345. NOTED: THROUGH WALL PENETRATION ON SEVERAL LOCATIONS IN ELECTRICAL SWITCH GEAR ROOM AND OUTSIDE ELECTRICAL ROOM ABOVE #35725597H | Oct 24, 2025 POP/IN-VIO | $0 |
| Jan 15, 2025 | Unknown CLASS - 2 DURING INSPECTION OF A 3 STORY SCHOOL BUILDING WITH A SIDEWALK SHED AROUND THE PERIMETER, I OBSERVED THAT THE LIGHTS WERE ON UNDER THE SHED. DOB RECORDS REVEALED THAT THE ELECTRICAL PERMIT HAD EXPIRED ON APRIL #39535980Z | Feb 12, 2026 DEFAULT | $0 |
| Jul 7, 2023 | Construction CLASS - 2 REISSUE #3563368N FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT ROOFTOP INSIDE THE PARAPET MISSING FLASHING AND ALUMINUM PANELS THROUGHOUT THE ROOFTOP. REMEDY: REPAIR/REPLACE #35663559X | Sep 26, 2023 POP/IN-VIO | $0 |
| Jul 29, 2022 | Construction CLASS - 2 REISSUE35578240H DOI5.28.21 FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER ATOI I OBSERVED&NOTED THAT@ROOF LEVEL METALLIC SHEET COVERING PARAPET WALL ITS DETACHED.MISSING B/C ITS NOT ANCHORED OR SECURED IN LO #35663368N | Oct 25, 2022 POP/IN-VIO | $0 |
| May 28, 2021 | Construction CLASS - 2 REISSUE#35496049K FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED: AT ROOF LEVEL,METALIC SHEET COVERING THE PARAPET WALL,IT IS DETACHED,MISSING BECAUSE IT IS NOT ANCHORED OR SECURED IN THE LOWER SID #35578240H | Sep 14, 2021 POP/IN-VIO | $0 |
| Jun 2, 2020 | Construction CLASS - 2 REISSU #35434068M FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. NOTED: @ROOF TOP INSIDE THE PARAPET MISSING FLASHING & ALUMINIM PANELS THROUGH OUT THE ROOF TOP.REM: MAKE NECESSARY REPAIRS #35496049K | Sep 15, 2020 POP/IN-VIO | $0 |
| Jul 12, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED: AT ROOF TOP INSIDED THE PARAPET MISSING FLASHING AND ALUMINUM PANELS THROUGH OUT THE ROOF TOP. REMEDY: MAKE NECESSARY REPAIRS. #35434068M | Oct 15, 2019 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 23, 2024 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023) #00623 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Jun 23, 2024 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 5:14 AM ET. BBL 4099190006.