Queens · Block 9915 · Lot 7501 · 11432

88-11 179 Place

8 floors · 49 apartments · 49,867 sq ft · built 2023 · class RM · owner of record: Priya Llc

0open violations
$9,900ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 118 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 49,867 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 431 days
Next cycle year 2027

Open violations

ECB / OATH (3) · $9,900 owed
IssuedViolationHearingBalance
May 13, 2024Plumbing CLASS - 1
DURING INSPECTION OF A 8 STORY BUILDING WITH ACTIVE CONSTRUCTION, THE STANDPIPE WAS PAINTED RED AND IN PLACE UP TO THE ROOF. I REQUESTED TO SEE THE MASTER PLUMBER PRESSURE TESTING DOCUMENT, BUT NONE WAS PROVIDE
#39528535P
Apr 22, 2025
IN VIOLATION
$5,000
Feb 20, 2024Unknown CLASS - 2
FAILURE TO PROVIDE/MAINTAIN SUPPORTED PIPE SCAFFOLD AS PER CODE - BC 3314.4.8: AT TIME OF INSPECTION, IT WAS OBSERVED: SUPPORTED PIPE SCAFFOLD WITH LOOSE OSHA PLANKS ON EXPOSURE 1&4, NOT FULLY PLANKED AND LOOSE
#39525714R
Feb 11, 2025
IN VIOLATION
$2,500
Sep 29, 2023Construction CLASS - 2
PROPOSED 8 STORY NB(87FEET HIGH) CURRENTLY FORMING 6FL, I OBSERVED CLOSED SITE, WITH MISSING SIDEWALK SHED AT EXP1(SIDEWALK APPROXIMATELY 30F AWAY FROM BUILDING, WHICH IS LESS THAN THE HALF THE HEIGHT AS REQUIR
#39522228H
Sep 17, 2024
IN VIOLATION
$2,400
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 11:20 AM ET. BBL 4099157501.

Look up another building