Brooklyn · Block 8066 · Lot 36 · 11236

8702 Avenue L

2 floors · 5,220 sq ft · built 1962 · class K2 · owner of record: 8702 Hk Realty, Llc

3open violations
$1,250ECB/OATH penalties owed
0HPD class C (immediately hazardous)
1161dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 65 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 18 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1161 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-13 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (2) · $1,250 owed
IssuedViolationHearingBalance
Oct 4, 2018Construction CLASS - 2
FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35184364H ISSUED ON 08-30-17 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS/AMENDM
#35389656Z
Mar 25, 2019
IN VIOLATION
$1,250
Mar 30, 2017Construction CLASS - 2
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.PREMISES UNDER ALT2 JOB3321314109 L.O.C FOLDER.AT TIME OF INSPECTION FOUND.CONFIGURATION OF PARTITION WALL IS NOT HOW PLAN PRO
#35184364H
Dec 20, 2017
IN VIOLATION
$0
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 18)
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 7:03 PM ET. BBL 3080660036.