| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 73,272 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 412 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2179). Agency page | Dec 31, 2029 in 1143 days | Next due 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-03 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 26, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED SEVERAL CRACKS AND SPALLING TO MASONRY BRICK ABOVE WINDOWS AT EXPOSURE #2,#4 ALSO VIOLATION #39145289K ISSUED ON 04-17-2025 FOR FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANC #39209397H | Dec 31, 2026 PENDING | $12,500 |
| Sep 1, 2026 | Elevators CLASS - 1 CLASS1 ITEM: RTS FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER, SERVICE ELEVATOR EQUIPMENT AS PER CODE BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS #39202533L | Nov 5, 2026 DEFAULT | $1,280 |
| Apr 20, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AS NOTED: AT TIME OF INSPECTION OBSERVED RETAINING WALL(RW) AT EXPOSURE #2 ALONG WITHNEIGHBOR(875 WEST 181ST MANHATTAN NY). OBSERVED RW AND MEASURED APPROX #35726535R | Jun 25, 2026 DEFAULT | $12,500 |
| Apr 17, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALLS & APPURTENANCES. AT TIME OF INSPECTION OBSERVED AT EXPOSURE# 2/3/4 MULTIPLE LOCATIONS MAINLY ABOVE/BELOW WINDOWS, SEVERE SPALLING TO MASONRY BRICK WORK WHERE STRUCTURAL MORTAR #39145289K | Jul 24, 2025 IN VIOLATION | $5,000 |
| Apr 12, 2024 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH DEPARTMENT OF BUILDINGS. NOTE: RESPONDNET FAILURE TO COMPLY WITH PRIOR SUMMON #35679664Y DATED(01/10/24). AT TIME OF INSPECTI #35681633Y | Jun 20, 2024 DEFAULT | $6,250 |
| Apr 12, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES. AT TIME OF INSPECTION, I OBSERVED DAMAGED WATERTABLE(TERRA-COTTA), CRACKED TERRA-COTTA, CRACKED WATER TABLE(LEVEL 1), DEFECTED MORTAR JOINTS ON WATER TABLE #35681632M | Jun 20, 2024 DEFAULT | $12,500 |
| Jan 10, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING FACADE & APPURTENANCES.NOTE:OBSERVED AT EXP #1 SOUTH ELEVATION VERTICAL CRACK UNDER WATER TABLE,ABOVE LEVEL 1 WATER TABLE CRACKS.CRACKS AT PARAPET WALL AT EXP #1 & MISSING BROKEN BR #35679664Y | Mar 21, 2024 IN VIOLATION | $6,250 |
| Dec 5, 2023 | Construction CLASS - 1 FAILURE TO PAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. OBSERVED AT EXPOSURE #1 VERTICAL CRACK UNDER WATER TABLE, ABOVE LEVEL 1. WATERABLE CRACK ALSO ON UPPER PARAPET AT EXPOSURE #1. OBSERVED OBJECTS ON #35675289N | Feb 8, 2024 DEFAULT | $12,500 |
| Dec 9, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 8A & 9A REPORT OF CRITICALEXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES RE QUIRED BY 28-302.4 FOR CONTROL #907273 AGG2 HISTORY OF NONCOMPLIANCE O #37024462L | Aug 24, 2023 IN VIOLATION | $6,250 |
| Mar 3, 2022 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#35507750J ISSUED ON 5/8/21 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.FAILURE TO MAINTAIN BUILDI #35568403Y | Jun 2, 2022 DEFAULT | $5,000 |
| Dec 21, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#35507750J ISSUED ON 5/5/2021 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.REMEDY:COMPLY WITH COMMI #35567604X | Jun 30, 2022 IN VIOLATION | $3,125 |
| Oct 29, 2021 | Construction CLASS - 2 FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V39034768X ISSUED 5/8/21 &TO FILE C/C PURSUANT TO28-201.1&1RCNY102-01.FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.COMPLY W/COMMISSIONER'S ORDER #35563901Y | Jan 27, 2022 DEFAULT | $10,000 |
| Sep 17, 2021 | Construction CLASS - 2 FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V35507750J ISSUED 5/8/21 &TO FILE C/C PURSUANT TO28-201.1&1RCNY102-01.FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.COMPLY W/COMMISSIONER'S ORDER #35536534H | Jun 2, 2022 IN VIOLATION | $3,125 |
| Jun 11, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS.VIOLATION #35507750J ISSUED ON 05-08-21 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.COMPLY WITH COMMISSIONER #35532775K | Jun 16, 2022 IN VIOLATION | $6,250 |
| May 8, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. NOTED: AT APT#6A FLOORS W/SIGNIFICANT SLOPING,CRACKS IN WALLS & CEILINGS. DOOR JAMB OUTOF PLUMB & SAGGING CEILING THAT HAVE WATER DAMAGE. REMEDY: REPAIR &/OR #35507750J | Jun 16, 2022 IN VIOLATION | $0 |
| Apr 1, 2021 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 8A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 18-302.4 FOR CONTROL #807273.AGG1:PRIOR NOV 37010466 UNDER 28-3 #37021091H | Apr 28, 2022 DEFAULT | $10,000 |
| Jun 29, 2020 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35344914N ISSUED ON 10-10-2018,AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01(D)(2) FILE A CERTIFICATE O #37019302X | Sep 24, 2020 DEFAULT | $3,125 |
| May 22, 2020 | Elevators CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY; FILE APPLICATION, INSTALL DLM A #39022671L | Oct 15, 2020 DEFAULT | $2,868 |
| Jul 11, 2019 | Construction CLASS - 2 NOTED DUE TO WATER LEAKS CEILING PLASTER DISCOLORED AND IN DISREPAIR IN REAR ROOM AND BED ROOM. ALSO NOTED CRACKS IN CORNER OF BOTH LOCATIONS., REPAIR AND/OR REPLACE; REPAIR CEILING AND CRACKS. FIX LEAK #39005324M | Aug 29, 2019 DEFAULT | $3,125 |
| Jul 10, 2019 | Construction CLASS - 1 NOTED IN BASEMENT COMBUSTIBLE MATERIAL MADE UP OF LUMBER AND CONSTRUCTION DEBRIS PILED 6 FT HIGH IN AREA 20 FT BY 15 FT. MATERIAL CREATES FIRE HAZARD TO AN FULLY OCCUPIED BUILDING., MAINTAIN STORAGE IN COMPLIA #39005255H | Aug 29, 2019 ADMIT/IN-VIO | $0 |
| Oct 10, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING.1 PARAPET S.E. CORNER CRQACKED TERR COTTA/CRACK IN BRICK.2.GROUND FLOOR BAN BROKEN OFF CORNER.3-NEAR ENTRANCE -A/C UNITS BLOCKING EGRESS AT FIRE ESCAPES.4-FLOWER ON 6 FL. #35344914N | Dec 6, 2018 DEFAULT | $12,500 |
| Oct 10, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN FACADE SOUTH ELEV.EXP.1-1-DECORATIVE PARAPET MUSS GROCET IN VARIOUS LOCATION.2-COPING SONE CRACKED OR MISSING OR DISLODGED.3-FIRE ESCAPE RUSTING.4-VERTICLE AND HORINZONTAL CRACKS IN BRICK & #35344915P | Dec 6, 2018 DEFAULT | $6,250 |
| May 18, 2018 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#807273.REM:SUBMIT REQUIRED TECHNICAL REPORT. #37010466L | Sep 13, 2018 DEFAULT | $6,250 |
| Dec 10, 2016 | Construction CLASS - 1 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN NOV #35197146M ISSUED ON 06/29/16 & TO FILE A C OF C PURSUANT TO 28-201.1,28-204.4 & 1RCNY102-01. FOR WORK W/O A PERMIT AT 1ST FL APT #11. REMEDY: COMPLY W/COMM #35190533K | May 25, 2017 WRITTEN OFF | $0 |
| Oct 22, 2016 | Construction CLASS - 1 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN NOV #35197146M ISSUED ON 06/29/16 & TO FILE A C OF C PURSUANT TO 28-201.1,28-204.4 & 1RCNY102-01. REMEDY: COMPLY W/COMM'S ORDER &/OR FILE A C OF C #35189008Y | Jan 19, 2017 IN VIOLATION | $0 |
| Aug 23, 2016 | Construction CLASS - 1 FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN NOV#35197146M ISSUED ON 06/29/16 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 280201.1, 28-204.4 AND 1RCNY 102-01.WORK W/O PERMIT.RMDY:COMPLY W/ #35187868P | Dec 15, 2016 WRITTEN OFF | $0 |
| Jun 29, 2016 | Construction CLASS - 1 WORK WITHOUT A PERMIT. NOTED:AT 1ST STORY, APT1I, AT WEST SECTION OF BUILDING FACING SOUTH-WEST COMPLETE GUT RENOVATION BEING TONE CONSISTING OF INSTALLING NEW SHEETROCK ON WALLS. ALL KITCHEN AND BATHROOM FIXTU #35197146M | Dec 1, 2016 IN VIOLATION | $0 |
| Nov 22, 2014 | Construction CLASS - 2 WORK W/O A PERMIT: WORK NOTED: AT 1ST FLR IN APT #1H HAVING CONSTRUCTION WORK IN PROGRESS AS PAINTING PARTITION 90% OF WORK DONE FOR BATHRM RENOVATION (CEMENT BOARDS,TILES) 100% OF WORK DONE FOR FLOORING REPLAC #35074495K | May 21, 2015 DEFAULT | $0 |
| Sep 28, 2011 | Construction CLASS - 2 WORK W/O A PERMIT.PLUMBING/ELECTRICAL NOTED:5E 1)ALL NEW ELECTRICAL WORK DONE IN APT 2)NEW BATHROOM-ALL NEW PLUMBING COPPER PIPING,TUB & SHOWER BODY.3)APPROX 75% OF APT COMPLETE TILES IN KITCHEN FL,COMPOUND NO #34887517Y | Nov 17, 2011 DEFAULT | $0 |
| Jan 25, 2011 | Local Law CLASS - 2 FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS PERIODIC INSP OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED BY ARTICLE 28.302 AND THE DOB RULES AND REGULATIONS REM: #36016163P | Aug 4, 2011 WRITTEN OFF | $0 |
| Jun 4, 2010 | Construction CLASS - 2 FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEW/CODE PROVISIONS:PERIODIC INSPECTION OF EXTERIOR WALLS & APPURTENACESAS REQUIRED BY ARTICLE 28.302 & THE DOB RULES & REGULATIONS.REM:FILE T #36013421P | Feb 3, 2011 IN VIOLATION | $0 |
| Jan 23, 2009 | Construction CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED BY ARTICLE 28.302 & THE DOB RULES & REGULATIONS #36007803J | Jul 15, 2010 IN VIOLATION | $0 |
| May 11, 1993 | Local Law Hazardous FAILURE TO FILE AN AMENDED REPORT ACCEPTABLE TO THIS DEPARTMENT PURSU-TO RULE RCNY 32-03B (5) INDICATING CORRECTION OF HAZARDOUS CONDITION DESCRIBED IN INITIAL LL10/80 REPORT. REMEDY: FILE AN AMMENDED REPORT F #34079338N | Jun 17, 1993 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Apr 20, 2026 | CONSTRUCTION AT TIME OF INSPECTION,IT WAS OBSRVD THAT A STONE RETAINING WALL IS CRACKED-SPALLED ROCKS HAVE VERT & HOTIZONTL CRACKS CREATE HAZARDOUS CONDITONS FOR ROCKS TO FALLING DOWN.IMPLEMENT ANY NECESSARY SAFETY MEASURES IMMEDIATELY.EMAIL REPORT TO FORENSICENG@BUILDINGS.NYC.GOV #RW11201JL | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #04745 | DOB VIOLATION - ACTIVE |
| Feb 22, 2022 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 #00754 | DOB VIOLATION - ACTIVE |
| Aug 4, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00100 | DOB VIOLATION - ACTIVE |
| Apr 29, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2001591 | DOB VIOLATION - ACTIVE |
| Oct 17, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00339 | DOB VIOLATION - ACTIVE |
| Jan 9, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00115 | DOB VIOLATION - ACTIVE |
| May 31, 2018 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 #00357 | DOB VIOLATION - ACTIVE |
| Sep 21, 2016 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00101 | DOB VIOLATION - ACTIVE |
| Nov 22, 2014 | CONSTRUCTION #12VF01 | VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE |
| Jan 1, 2012 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00881 | DOB VIOLATION - ACTIVE |
| Nov 30, 2007 | LOCAL LAW 11/98 - FACADE #NRF44403 | DOB VIOLATION - ACTIVE |
| Jan 31, 2005 | LOCAL LAW 62/91 - BOILERS #00508 | DOB VIOLATION - ACTIVE |
| Feb 13, 2004 | LOCAL LAW 62/91 - BOILERS #00516 | DOB VIOLATION - ACTIVE |
| Mar 18, 1993 | LOCAL LAW 62/91 - BOILERS #01330 | DOB VIOLATION - ACTIVE |
| Mar 2, 1992 | CONSTRUCTION #D$SI)@ | VIOLATION UNSERVED ECB-ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Report | Active |
| Aug 4, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Apr 29, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Oct 17, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 9, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| May 31, 2018 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 | Active |
| Sep 21, 2016 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 1, 2012 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Nov 30, 2007 | Facades LL1198 CYCLE 6 NO REPORT FILED | Active |
| Jan 31, 2005 | Boiler LL6291 | Active |
| Feb 13, 2004 | Boiler LL6291 | Active |
| Mar 18, 1993 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 24, 2026 | B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING OF WEST BULKHEAD AT PUBLIC HALL STAIRS, 6th STORY ORIGINAL VIOLATION 18957072 ISSUED 26-MAY-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b). | Oct 29, 2026 |
| Sep 8, 2026 | B | Apt 4F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM EAST LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 13, 2026 |
| Sep 8, 2026 | B | Apt 4F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 13, 2026 |
| Sep 8, 2026 | B | Apt 4F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD BOTTOM PANEL INSIDE BASE CABINET AT SINK IN THE KITCHEN LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 13, 2026 |
| Sep 8, 2026 | B | Apt 4F · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 13, 2026 |
| Sep 8, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND ALL WALLS AT PUBLIC HALL, 5th STORY | Oct 13, 2026 |
| Sep 8, 2026 | B | Apt 4F · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 13, 2026 |
| Sep 8, 2026 | B | Apt 4F · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT BATHTUB IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 13, 2026 |
| Sep 8, 2026 | B | Apt 4F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 13, 2026 |
| Sep 8, 2026 | B | Apt 4F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 13, 2026 |
| Sep 8, 2026 | B | Apt 4F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 13, 2026 |
| Sep 8, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS AT PUBLIC HALL, 5th STORY | Dec 12, 2026 |
| Sep 8, 2026 | B | Apt 4F · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 13, 2026 |
| Sep 8, 2026 | B | Apt 4F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 4th ROOM FROM EAST LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 13, 2026 |
| Sep 8, 2026 | B | Apt 4F · 566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF TERMITES IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 13, 2026 |
| Sep 4, 2026 | B | Apt 3F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST'' | Oct 9, 2026 |
| Sep 1, 2026 | B | Apt 3F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 6, 2026 |
| Sep 1, 2026 | B | Apt 3F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 4th ROOM FROM EAST LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 6, 2026 |
| Sep 1, 2026 | C | Apt 3F · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Sep 15, 2026 |
| Sep 1, 2026 | A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Dec 5, 2026 |
| Sep 1, 2026 | B | Apt 3F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 6, 2026 |
| May 27, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING OF WEST BULKHEAD AT PUBLIC HALL STAIRS, 6th STORY | Jul 1, 2026 |
| May 27, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT WEST BULKHEAD AT PUBLIC HALL STAIRS, 6th STORY | Aug 30, 2026 |
| Jan 26, 2026 | B | Apt 5F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH 1ST WINDOW AT SOUTH IN THE 4th ROOM FROM EAST LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 2, 2026 |
| Jan 26, 2026 | B | Apt 5F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH 2ND WINDOW AT SOUTH IN THE 2nd ROOM FROM EAST LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 2, 2026 |
| Jan 26, 2026 | B | Apt 5F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH 1ST WINDOW AT SOUTH IN THE KITCHEN LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 2, 2026 |
| Jan 26, 2026 | B | Apt 5F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH 1ST WINDOW AT SOUTH IN THE 2nd ROOM FROM EAST LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 2, 2026 |
| Jan 26, 2026 | B | Apt 5F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH 1ST WINDOW AT SOUTH IN THE BATHROOM LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 2, 2026 |
| May 14, 2025 | B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONSISTING OF EXCESSIVE VEGETATION IMPEDING EGRESS TO STREET AT FIRE PASSAGE WAY AT EAST | Jun 18, 2025 |
| May 13, 2025 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND SOUTH WALL , 6th STORY | Aug 16, 2025 |
| May 13, 2025 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND SOUTH WALL AT BULKHEAD , 6th STORY | Jun 17, 2025 |
| May 13, 2025 | B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AT BULKHEAD , 6th STORY | Jun 17, 2025 |
| May 13, 2025 | B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL AT BULKEAD , 6th STORY | Jun 17, 2025 |
| May 6, 2025 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BULKHEAD DOOR , 6th STORY | May 20, 2025 |
| May 6, 2025 | C | Apt 4K · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4K, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''WEST'' | Jun 1, 2025 |
| Mar 6, 2025 | B | Apt 6K · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 6K, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT WEST | Apr 10, 2025 |
| Mar 6, 2025 | B | Apt 6K · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6K, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT WEST | Apr 10, 2025 |
| Mar 6, 2025 | B | Apt 6K · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6K, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT WEST | Apr 10, 2025 |
| Dec 15, 2023 | B | Apt 4J · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 1 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 4J, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 16167008 ISSUED 16-AUG-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a( | Jan 19, 2024 |
| Nov 24, 2023 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM AT CELLAR | Nov 30, 2023 |
| Nov 24, 2023 | C | Apt 6A · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Nov 23, 2023 |
| May 8, 2023 | B | Apt 3D · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER THE CEILING IN THE KITCHEN LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 12, 2023 |
| May 8, 2023 | A | Apt 3D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 11, 2023 |
| May 8, 2023 | A | Apt 3D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE TOP ESCUTCHEON PLATE AT HEATING RISER IN THE 1st ROOM FROM NORTH AT CENTER LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 11, 2023 |
| May 8, 2023 | A | Apt 3D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH AT CENTER LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 11, 2023 |
| May 8, 2023 | B | Apt 3D · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER THE CEILING NEARBY THE HEATING RISER IN THE 1st ROOM FROM NORTH AT CENTER LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 12, 2023 |
| May 8, 2023 | A | Apt 3D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND ALL WALLS IN THE KITCHEN LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 11, 2023 |
| May 8, 2023 | A | Apt 3D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 11, 2023 |
| May 8, 2023 | A | Apt 3D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 11, 2023 |
| May 8, 2023 | A | Apt 3D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE PRIVATE HALLWAY LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 11, 2023 |
| May 8, 2023 | A | Apt 3D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 11, 2023 |
| May 8, 2023 | C | Apt 3D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 3, 2023 |
| Dec 2, 2022 | B | Apt 5I · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 5I, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST | Jan 20, 2023 |
| Dec 2, 2022 | C | Apt 5I · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) WEST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 5I, 5th STORY, 3rd APARTMENT FROM | Dec 26, 2022 |
| Dec 2, 2022 | A | Apt 5I · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 5th ROOM FROM NORTH, THE BATHROOM , THE 1st ROOM FROM NORTH LOCATED AT APT 5I, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST | Mar 7, 2023 |
| Nov 23, 2022 | B | Apt 2A · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 2A, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH | Jan 11, 2023 |
| Nov 23, 2022 | B | Apt 1H · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE UPPER ESCUTCHEON PLATE AT STEAM RISER AT EAST IN THE BATHROOM LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST | Dec 28, 2022 |
| Nov 23, 2022 | B | Apt 5D · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 11, 2023 |
| Nov 23, 2022 | B | Apt 4K · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 4K, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 11, 2023 |
| Nov 23, 2022 | B | Apt 4H · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 4H, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST | Jan 11, 2023 |
Showing 60 of 319. Full list on the agency site.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Oct 26, 2026 | ECB | Construction: AT TIME OF INSPECTION OBSERVED SEVERAL CRACKS AND SPALLING TO MASONRY BRICK ABOVE WINDOWS AT EXPOSURE #2,#4 ALSO VIOLATION #39145289K ISSUED ON 04-17-2025 FOR FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANC | Open |
| Sep 24, 2026 | HPD B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING OF WEST BULKHEAD AT PUBLIC HALL STAIRS, 6th STORY ORIGINAL VIOLATION 18957072 ISSUED 26-MAY-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b). | Open |
| Sep 8, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM EAST LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 8, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 8, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD BOTTOM PANEL INSIDE BASE CABINET AT SINK IN THE KITCHEN LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 8, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 8, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND ALL WALLS AT PUBLIC HALL, 5th STORY | Open |
| Sep 8, 2026 | HPD B | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 8, 2026 | HPD B | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT BATHTUB IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 8, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 8, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 8, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 8, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS AT PUBLIC HALL, 5th STORY | Open |
| Sep 8, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 8, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 4th ROOM FROM EAST LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 8, 2026 | HPD B | 566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF TERMITES IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 4, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST'' | Open |
| Sep 1, 2026 | ECB | Elevators: CLASS1 ITEM: RTS FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER, SERVICE ELEVATOR EQUIPMENT AS PER CODE BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS | Open |
| Sep 1, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 1, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 4th ROOM FROM EAST LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 1, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 1, 2026 | HPD A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Open |
| Sep 1, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)