4 floors · 8 apartments · 9,000 sq ft · built 1910 · class C1 · owner of record: 863 Hancock Ny Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 797 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jan 4, 2013 | Boilers CLASS - 2 B254,32,36,50,50A,B,C,D,E. 50- SPILL SWITCH DEFECTIVE. 50A- SINGLE WALL FLUES THRU BOILER ROOM CEILING. 50B- HOT WATER HEATER INSTALLED W/O MIN. CLEARANCE FOR SERVICE ACCESS. 50C- FRESH AIR DUCT MISSING (FIRE) #32072933N | Feb 25, 2013 WRITTEN OFF | $0 |
| Jan 4, 2013 | Construction CLASS - 1 B101 - WILLIAMSON GWA052 BOILER INSTALLED WITHOUT BL WORK TYPE PERMIT #32072929K | Feb 25, 2013 WRITTEN OFF | $0 |
| Jan 4, 2013 | Boilers CLASS - 2 B254,36,50,50A,B,C,D. 50- SPILL SWITCH DEFECTIVE. 50A- SINGLE WALL FLUES THRU BOILER ROOM CEILING. 50B- WASHER AND DRYER WALL CONNECTIONS INBOILER ROOM. 50C- FIRE DAMPER MISSING IN BOILER ROOM FRESH AIR DUCT. #32072934P | Feb 25, 2013 WRITTEN OFF | $0 |
| Jan 4, 2013 | Boilers CLASS - 2 B254,36,50A,B,C,D,E,32,50. 50- SPILL SWITCH DEFECTIVE. 50A- SINGLE WALL FLUES THRU BOILER ROOM CEILING. 50B- WASHER & DRYER WALL CONNECTIONSIN BOILER ROOM. 50C- INDIVIDUAL BOILER MISSING THERMOSTAT CONTROL. 50D #32072932L | Feb 25, 2013 WRITTEN OFF | $0 |
| Jan 4, 2013 | Boilers CLASS - 2 B254,36,50,50A,B,C,D,E. 50- SPILL SWITCH DEFECTIVE. 50A- SINGLE WALL FLUES THRU BOILER ROOM CEILING. 50B- BOILER ROOM LIGHT DEFECTIVE. 50C-WASHER AND DRYER WALL CONNECTION IN BOILER ROOM. 50D- FRESH AIR DUCT #32072935R | Feb 25, 2013 WRITTEN OFF | $0 |
| Jan 4, 2013 | Boilers CLASS - 2 B254,32A,36,50,50A,B,C,D,E,F. 50- SINGLE WALL BOILER AND HOT WATER HEATER FLUES THROUGH BOILER ROOM CEILING. 50A- WASHER AND DRYER WALL CONNECTIONS IN BOILER ROOM. 50B- CHECK VALVE NOT INSTALLED BETWEEN BACK #32072930H | Feb 25, 2013 WRITTEN OFF | $0 |
| Jan 4, 2013 | Boilers CLASS - 2 B254,36,50,50A,B,C,D,E,F. 50- SPILL SWITCH DEFECTIVE. 50A- SINGLE WALLFLUE THRU BOILER ROOM CEILING. 50B- PIPE LEAKING ON HWH. 50C- CIRCULATOR DEFECTIVE. 50D- VALVE LEAKING ON RETURN LINE. 50E- FRESH AIR DUCT #32072936Z | Feb 25, 2013 WRITTEN OFF | $0 |
| Jan 4, 2013 | Boilers CLASS - 2 B254,15,24A,32A,36,50,50A,B,C,D,E. 50- SPILL SWITCH DEFECTIVE. 50A- SINGLE WALL FLUES THRU BOILER ROOM CEILING. 50B- BOILER ROOM LIGHT & DEFECTIVE. 50C- WASHER AND DRYER WALL CONNECTIONS IN BOILER ROOM. 50D- #32072937K | Feb 25, 2013 WRITTEN OFF | $0 |
| Jan 4, 2013 | Boilers CLASS - 2 B254,36,50,50A,B,C,D,E. 50- SPILL SWITCH DEFECTIVE. 50A- WASHER AND DRYER WALL CONNECTIONS IN BOILER ROOM. 50B- SINGLE WALL BOILER AND HWH FLUES THRU BOILER ROOM CEILING. 50C-FRESH AIR DUCT MISSING FIRE DAMPER #32072931J | Feb 25, 2013 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #09684 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #08622 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #34016 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION #13666 | DOB VIOLATION - ACTIVE |
| Apr 25, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION #19331 | DOB VIOLATION - ACTIVE |
| Mar 28, 2013 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00063 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #36720 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Apr 25, 2023 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT | Active |
| Mar 28, 2013 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 7:18 AM ET. BBL 3014870049.