4 floors · 15 apartments · 11,460 sq ft · built 1927 · class C1 · owner of record: 862 East 17 Street Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-10-23 (Accepted). Agency page | Dec 31, 2026 in 47 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 412 days | Next cycle year 2027 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #35956 | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 26, 2026 | B | § 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION EXTERIOR WINDOW CONVERTED TO DOOR AT SOUTH COURT YARD | Jun 30, 2026 |
| May 26, 2026 | C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WINDOW CONVERTED TO DOOR WITH BALCONY AND STAIRCASE AT SOUTH COURT | Jun 1, 2026 |
| Feb 5, 2026 | B | Apt B3 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 12, 2026 |
| Feb 5, 2026 | B | Apt B3 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 12, 2026 |
| Feb 5, 2026 | B | Apt B3 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 12, 2026 |
| Feb 5, 2026 | B | Apt B3 · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTELINE AT SINK IN THE BATHROOM LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 12, 2026 |
| Feb 5, 2026 | B | Apt B3 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE KITCHEN LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 12, 2026 |
| Dec 1, 2025 | B | Apt B3 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2026 |
| Dec 1, 2025 | B | Apt B3 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2026 |
| Dec 1, 2025 | A | Apt B3 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT ALL WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 6, 2026 |
| Dec 1, 2025 | B | Apt B3 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST , NORTH WALLS IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2026 |
| Dec 1, 2025 | B | Apt B3 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2026 |
| Dec 1, 2025 | B | Apt B3 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2026 |
| Dec 1, 2025 | A | Apt B3 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE FOYER LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 6, 2026 |
| Dec 1, 2025 | B | Apt B3 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2026 |
| Dec 1, 2025 | C | Apt B3 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Dec 7, 2025 |
| Dec 1, 2025 | B | Apt B3 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2026 |
| Dec 1, 2025 | B | Apt B3 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT B3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2026 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 10:11 AM ET. BBL 3067000018.