Manhattan · Block 2067 · Lot 44 · 10031

853 St Nicholas Avenue

6 floors · 24 apartments · 24,200 sq ft · built 1903 · class D1 · owner of record: 853 St. Nicholas Avenue Owner Llc

26open violations
$42,530ECB/OATH penalties owed
2HPD class C (immediately hazardous)
49dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 49 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 49 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 49 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 65 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 293 days
Registered through 2027-09-01
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-18 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (10) · $42,530 owed
IssuedViolationHearingBalance
Aug 5, 2026Unknown CLASS - 2
BC 3314.1 FAILURE TO MAINTAIN SCAFFOLD AT TIME OF INSPECTION OF A 6 STORIES BUILDING I OBSERVED SUPPORTED SCAFFOLD IN PLACE AT EXPOSURE #1 WITH TORN AND DISCONNECTED DEBRI SAFETY FLAPPING IN THE AIR , THIS CREA
#39557563P
Oct 15, 2026
DEFAULT
$2,530
May 6, 2026Construction CLASS - 2
FAILURE TO PROVIDE ADEQUATE PEDESTRIAN PROTECTION. NOTED AT TIME OF INSPECTION UNSECURED DEBRIS NETTING ON SUPPORTED SCAFFOLDING WAS OBSERVED AT EXPOSURE 1 AT PARAPET LEVEL AND ALSO EAST OF EXPOSURE ONE. REMEDY
#35729751P
Jun 8, 2027
DEFAULT
$5,000
Sep 18, 2024Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTE:AIR CONDITIONING UNITS OBSTRUCTING EGRESS AT 5TH AND 7TH STORY LANDINGS AT FIRE ESCAPE AT EXPOSURE#3 WEST ELEVATION.TEMPORARY PLYWOOD COVERS OBSTRUCING EGRES
#35686293J
Dec 5, 2024
DEFAULT
$6,250
Aug 21, 2024Unknown CLASS - 2
AT TIME OF INSPECTION OBSERVED SIDEWALK SHED AND PIPE SCAFFOLD ERECTED AT EXPOSURE #1 OBSERVED DEBRIS NETTING FOR THE PIPE SCAFFOLD HAS OPEN GAPS AND WAS NOT SECURE TO THE BUILDING FACADE-BC3314.8.2...
#39531656Z
Oct 31, 2024
DEFAULT
$10,000
May 31, 2024Unknown CLASS - 2
AT TIME OF INSPECTION OF A 6 STORY RESIDENTIAL BUILDING OBSERVED SUPPORTED SCAFFOLD IN PLACE WITH NETTING NOT MAINTAINED PER CODE 3314.8.2 CAUSING HAZARDOUS CONDITIONS.MAINTAIN SCAFFOLD
#39529160M
Jul 2, 2025
IN VIOLATION
$2,500
Apr 11, 2024Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #906983. REMEDY: SUBMIT ACCEPTABLE REQU
#37027797R
Jul 11, 2024
DEFAULT
$6,250
Jan 16, 2024Local Law CLASS - 2
FAILURE TO FILE ACCEPATABLE AMENDED CYCLE 8B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#806983.AGG1:PRIOR NOV 37022232R UNDER 28-302.5
#37026093Y
Apr 11, 2024
DEFAULT
$10,000
Oct 8, 2021Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#806983. REMEDY: FILE ACCEPTABLE REPORT.
#37022232R
Mar 3, 2022
IN VIOLATION
$0
Aug 1, 2018Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#806983. REMEDY: FILE ACCEPTABLE REPORT
#37012219N
Jan 31, 2019
IN VIOLATION
$0
Dec 26, 2017Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.SOUTH ELEVATION EXPOSURE 2,OBSERVED STEP CRACKS/CRACKS ON BRICK MASONRY ON VARIOUS LOCATIONS LOCATIONS;DAMAGED BRICK MASONRY AT PARAPET WALL AT ROO
#35264997H
Feb 15, 2018
STIPULATION/IN-VIO
$0
DOB (7)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#04514
DOB VIOLATION - ACTIVE
Nov 26, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00045
DOB VIOLATION - ACTIVE
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#04402
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#07159
DOB VIOLATION - ACTIVE
Feb 22, 2023NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
#01631
DOB VIOLATION - ACTIVE
Feb 14, 2018FACADE SAFETY PROGRAM

#HAZ87191
DOB VIOLATION - ACTIVE
Feb 14, 2018FACADE SAFETY PROGRAM

#HAZ87192
DOB VIOLATION - ACTIVE
DOB NOW Safety (8)
IssuedViolationStatus
Jan 21, 2026Facades FTC-FC-UNSAFE
unsafe report filed
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 26, 2024AEUHAZ FTC-AEU-HAZ
Active
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Feb 22, 2023Facades FISPNRF
CYCLE 9B NO REPORT FILED
Active
Feb 14, 2018Facades FISP
CYCLE 8B UNSAFE REPORT FILED
Active
HPD (2) · C 2 · B 0 · A 0
IssuedClassViolationCorrect by
Oct 26, 2026CApt 103 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 103, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTNov 21, 2026
Oct 26, 2026CApt 103 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 103, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTNov 21, 2026

Issued in the last 120 days

DateSourceWhatNow
Oct 26, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 103, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Oct 26, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 103, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Oct 26, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTIRE APARTMENT LOCATED AT APT 103, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTClosed
Aug 5, 2026ECBUnknown: BC 3314.1 FAILURE TO MAINTAIN SCAFFOLD AT TIME OF INSPECTION OF A 6 STORIES BUILDING I OBSERVED SUPPORTED SCAFFOLD IN PLACE AT EXPOSURE #1 WITH TORN AND DISCONNECTED DEBRI SAFETY FLAPPING IN THE AIR , THIS CREAOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 12, 2026, 1:44 AM ET. BBL 1020670044.

Look up another building