3 floors · 5 apartments · 5,070 sq ft · built 1931 · class S9 · owner of record: 103 Eramus Corporation
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 60 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 76 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 304 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 17 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 425 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 11, 2020 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED:AT EXP#3,SHINGLES HAVE FALLEN EXPOSING THE ROTTED FIRE STOPPING AT VARIOUS AREAS. ALSO LOOSE ELECTRIC WIRE ARE HANGING DOWN. REMEDY:MAKE NECESSARY RE #35502606M | Aug 1, 2022 DEFAULT | $458 |
| Issued | Violation | Status |
|---|---|---|
| Jan 17, 2020 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT #01406 | DOB VIOLATION - ACTIVE |
| Mar 3, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT #12670 | DOB VIOLATION - ACTIVE |
| Mar 1, 2013 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT #13092 | DOB VIOLATION - ACTIVE |
| Dec 13, 2011 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT #17251 | DOB VIOLATION - ACTIVE |
| Dec 31, 2009 | LOW PRESSURE BOILER #20129 | DOB VIOLATION - ACTIVE |
| Jan 1, 2009 | LOCAL LAW 62/91 - BOILERS #16438 | DOB VIOLATION - ACTIVE |
| Jan 3, 2008 | LOCAL LAW 62/91 - BOILERS #16510 | DOB VIOLATION - ACTIVE |
| Jan 19, 2007 | LOCAL LAW 62/91 - BOILERS #16786 | DOB VIOLATION - ACTIVE |
| Jan 6, 2006 | LOCAL LAW 62/91 - BOILERS #16342 | DOB VIOLATION - ACTIVE |
| Jan 31, 2005 | LOCAL LAW 62/91 - BOILERS #17531 | DOB VIOLATION - ACTIVE |
| Feb 13, 2004 | LOCAL LAW 62/91 - BOILERS #18744 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #21091 | DOB VIOLATION - ACTIVE |
| Mar 26, 2002 | LOCAL LAW 62/91 - BOILERS #22567 | DOB VIOLATION - ACTIVE |
| Feb 27, 2001 | LOCAL LAW 62/91 - BOILERS #21405 | DOB VIOLATION - ACTIVE |
| Feb 7, 2000 | LOCAL LAW 62/91 - BOILERS #21802 | DOB VIOLATION - ACTIVE |
| Mar 16, 1999 | LOCAL LAW 62/91 - BOILERS #21513 | DOB VIOLATION - ACTIVE |
| May 4, 1998 | LOCAL LAW 62/91 - BOILERS #24000 | DOB VIOLATION - ACTIVE |
| Sep 16, 1997 | LOCAL LAW 62/91 - BOILERS #237102 | DOB VIOLATION - ACTIVE |
| Feb 10, 1997 | LOCAL LAW 62/91 - BOILERS #27417 | DOB VIOLATION - ACTIVE |
| Aug 29, 1995 | LOCAL LAW 62/91 - BOILERS #33003 | DOB VIOLATION - ACTIVE |
| Jun 1, 1994 | LOCAL LAW 62/91 - BOILERS #19467 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #32316 | DOB VIOLATION - ACTIVE |
| Jun 1, 1993 | LOCAL LAW 62/91 - BOILERS #19466 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 17) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jul 19, 2023 | I | § 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS VACATE ORDER NO # 232841 FOR 3RD STORY B-ROOM 1, EAST 1 | — |
| Jul 19, 2023 | I | § 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS VACATE ORDER NO # 232841 FOR 3RD STORY B-ROOM 2 | — |
| Jul 10, 2023 | C | § 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT ROTTED WOOD BEAMS AND FLOOR JOIST AT NORTHEAST CORNER AT CELLAR | Jul 16, 2023 |
| Jul 10, 2023 | B | § 185, 240 M/D LAW PROPERLY FIRE RETARD IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT THE CELLAR CEILING EXPOSED FLOOR JOIST ABOVE | Aug 14, 2023 |
| Jul 10, 2023 | B | § 65 M/D LAW PROVIDE UNDER COMPLETED PERMIT, A PROPER ENCLOSURE FOR THE CENTRAL HEATING PLANT, AT CELLAR | Aug 14, 2023 |
| Jun 26, 2023 | C | Apt 3R · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING THE MAXIMUM TEMPERATURE OF 130 DEGREES AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jul 2, 2023 |
| Sep 19, 2022 | C | Apt 3F · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH A | Oct 13, 2022 |
| Sep 16, 2022 | C | Apt 3F · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) SOUTH WALL, EAST WALL IN THE KITCHEN LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM | Oct 10, 2022 |
| Sep 16, 2022 | C | Apt 3F · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) WES | Oct 10, 2022 |
| Sep 16, 2022 | C | Apt 3F · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM WEST AT NORTH WALL, 1st WINDOW FRAME FROM EAST AT SOUTH WALL, 2nd | Oct 10, 2022 |
| Sep 16, 2022 | C | Apt 3F · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) BASEBOARD AT SOUTH WALL, BASEBOARD AT EAST WALL, 1st DOOR FROM NORTH AT EAST WALL, 1st | Oct 10, 2022 |
| Sep 16, 2022 | C | Apt 3F · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM WEST AT NORTH WALL DOOR FRAME, 1st DOOR FROM NORTH AT EAST WALL, 1st D | Oct 10, 2022 |
| Sep 16, 2022 | C | Apt 3F · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM NORTH AT EAST WALL IN THE FOYER LOCATED AT APT 3F, 3rd STORY, 1st | Oct 10, 2022 |
| Sep 16, 2022 | C | Apt 3F · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, 1st DOOR FRAME FROM WEST AT NORTH WALL, NORTH WALL, SOUTH WALL, EAST WALL, WE | Oct 10, 2022 |
| Jun 24, 2022 | B | Apt 3F · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 8 SQ AT THE CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 14901913 ISSUED 22-FEB-22 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE C | Jul 29, 2022 |
| Jun 23, 2022 | B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX. 4 SQ.FT AT PUBLIC HALL, 3rd STORY ORIGINAL VIOLATION 14883837 ISSUED 22-FEB-22 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). | Jul 28, 2022 |
| Feb 28, 2022 | C | Apt 3F · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 3F, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 6, 2022 |
| Feb 24, 2022 | C | Apt 3F · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM EAST AT SOUTH WALL, 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE | Mar 20, 2022 |
| Feb 24, 2022 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE EXTERIOR SIDINGS BUILDING AT EAST | Mar 31, 2022 |
| Feb 24, 2022 | C | Apt 3F · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st WINDOW FRAME FROM EAST AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 3F, | Mar 20, 2022 |
| Dec 17, 2021 | B | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FLOOR AND WALLS AT LOBBY, 1st STORY | Jan 21, 2022 |
| Dec 17, 2021 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD STAIRS AT PUBLIC HALL STAIRS | Jan 21, 2022 |
| Dec 17, 2021 | C | Apt 3F · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) SOUTH WALL IN THE KITCHEN LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM WEST AT NOR | Jan 10, 2022 |
| Dec 3, 2021 | C | Apt 3F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 29, 2021 |
| Dec 3, 2021 | C | Apt 3F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 29, 2021 |
| Dec 30, 2019 | C | Apt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE FOYER LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 27, 2020 |
| Dec 30, 2019 | C | Apt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st RISER FROM SOUTH AT WEST WALL IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 27, 2020 |
| Dec 30, 2019 | C | Apt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st RISER FROM SOUTH AT WEST WALL IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FRO | Jan 27, 2020 |
| Dec 30, 2019 | C | Apt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st RADIATOR FROM SOUTH AT WEST WALL, SOUTH WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 2R, 2nd STORY, 2n | Jan 27, 2020 |
| Dec 30, 2019 | C | Apt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) SOUTH WALL IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 27, 2020 |
| Dec 24, 2019 | C | Apt 2R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 14, 2020 |
| Dec 24, 2019 | B | Apt 2R · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 28, 2020 |
| Dec 24, 2019 | C | Apt 2R · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 4; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 2nd APA | Jan 21, 2020 |
| Dec 24, 2019 | C | Apt 2R · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Dec 21, 2019 |
| Dec 24, 2019 | C | Apt 2R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 14, 2020 |
| Dec 24, 2019 | B | Apt 2R · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE .. LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 28, 2020 |
| Dec 24, 2019 | C | Apt 2R · § 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE IN THE ENTRANCE LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 14, 2020 |
| Dec 24, 2019 | C | Apt 2R · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES ..GAS RANGE IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 1, 2020 |
| Dec 5, 2019 | B | Apt 3R · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 9, 2020 |
| Nov 29, 2019 | B | Apt 3R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 3R, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 3, 2020 |
| Nov 29, 2019 | B | Apt 3R · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 3R, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 3, 2020 |
| Apr 12, 2016 | C | § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF RODENTS RATS AT PUBLIC HALL, 1st STORY | Apr 20, 2016 |
| Jun 16, 2011 | B | Apt 3R · § 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 3R, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jul 21, 2011 |
| Jun 16, 2011 | A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DOOR TO CELLAR CEALED NAIL SHUT AT PUBLIC HALL, 1st STORY | Sep 19, 2011 |
| Apr 25, 2011 | B | Apt 2R · § 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | May 30, 2011 |
| Apr 12, 2011 | B | Apt 3R · § 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE ... AT ENTRANCE ..., LOCATED AT APT 3R, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''103 ERASMU'', AT SOUTH | May 17, 2011 |
| Apr 12, 2011 | B | Apt 2F · § 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE AT ENTRANCE, LOCATED AT APT 2F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''103 ERASMU'', AT SOUTH | May 17, 2011 |
| Aug 1, 2007 | B | Apt FIRE · § 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION APT COUNT HAS CHANGE FROM 4 A CLASS UNITS TO 6 A CLASS UNITS | Sep 5, 2007 |
| Jul 28, 2006 | A | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNPAINTED WOOD CORNICE SOUTH AND WEST ROOF | Nov 24, 2006 |
| Jul 28, 2006 | A | § 27-2014 ADM CODE PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EXTERIOR WINDOW FRAMES AND SASHES 3 STY FRONT BLDG. | Nov 24, 2006 |
| Jul 28, 2006 | A | § 27-2014 ADM CODE PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EXTERIOR WINDOW FRAMES AND SASHES 2 AND 3 STY WEST SIDE. | Nov 24, 2006 |
| Jul 28, 2006 | A | § 27-2014 ADM CODE PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EXTERIOR WINDOW FRAMES AND SASHES 2 AND 3 STY SOUTH WEST BUILDING | Nov 24, 2006 |
| May 30, 2003 | I | Apt BLDG · § 27-2089 ADM CODE THE PREMISES HAVE BEEN VACATED BY AN ORDER OF THIS DEPARTMENT AND CANNOT BE REOCCUPIED EXCEPT FOR CARETAKER UNTIL A NEW CERTIFICATE OF OCCUPANCY HAS BEEN OBTAINED. | Sep 7, 2003 |
| Aug 27, 2001 | B | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL CEILING CELLAR THROUGHOUT. | Oct 6, 2001 |
| Aug 27, 2001 | C | § 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT ROTTEN WOOD BEAMS CRACKED BRICK FOUNDATION NORTHEAST CORNER CELLAR ER1 DOB 3065146 | Sep 7, 2001 |
| Aug 27, 2001 | B | D26-11.01, 11.03, 11.05 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CELLAR THRU OUT. | Oct 6, 2001 |
| Aug 27, 2001 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDED MATERIAL CEILING HALL SECTION CELLAR | Oct 6, 2001 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 3:24 PM ET. BBL 3051050001.